• Title/Summary/Keyword: Instantaneous Frequency

Search Result 337, Processing Time 0.027 seconds

S-Domain Equivalent System for Electromagnetic Transient Studies PART II : Frequency Dependent AC System Equivalent (전자기 과도현상 해석을 위한 S 영역 등가시스템 PART II: 주파수 의존 교류 시스템 등가)

  • Chung Hyeng-Hwan;Wang Yong-Peel
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.165-171
    • /
    • 2005
  • Electromagnetic transient simulation can be used to model complex non-linearities that very difficult to represent adequately in the frequency domain. This problem is greatly reduced with the use of frequency dependent network equivalents for the linear part of the system. S-domain rational function fitting techniques for representing frequency dependent equivalents have been developed using Least Squares Fitting(LSF). However it does not suffer the implementation error that exited in this work as it ignored the instantaneous term. This paper presents the formulation for developing 2 port Frequency Dependent AC System Equivalent(FDACSE) with the instantaneous term in S-domain and illustrates its use. This 2 port FDNE have been applied to the New Zealand AC system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the 2 port (FDACSE) developed with Norton Equivalent network. The study results have indicated the robustness and accuracy of 2 port FDACSE for electromagnetic transient studies.

Instantaneous Frequency Estimation of Doppler Signal using Wavelet Transform (웨이브릿 변환을 이용한 도플러 신호의 순간 주파수 추정)

  • Son Joong-Tak;Lee Seung-Houn;Park Kil-Houm
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.3 s.303
    • /
    • pp.99-106
    • /
    • 2005
  • Instantaneous Frequency(IF) of Doppler signals is used to get the information of relative velocity and miss distance between a missile and the corresponding target. Though Short-Time Fourier Transform(STFT) is mainly used to estimate IF, it has many errors in wide band signals where frequency changes sharply. Because it has a fixed window in time and frequency axes. This paper deals with IF estimation of Doppler signal using a Continuous Wavelet Transform(CWT) which has adaptive window in time and frequency axes. The proposed method is able to estimate IF regardless of frequency changes because it has a narrow window in high frequency band and a wide window in low frequency band. The experimental results demonstrate that the proposed method outperforms STFT in estimating IF.

Source Identification of Non-Stationary Sound.Vibration Signals Using Multi-Dimensional Spectral Analysis Method (다차원 스펙트럼 해석법을 이용한 비정상 소음.진동 신호의 소음원 규명)

  • Sim, Hyoun-Jin;Lee, Hae-Jin;Lee, You-Yub;Lee, Jung-Youn;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1154-1159
    • /
    • 2006
  • In this paper, time-frequency analysis and multi-dimensional spectral analysis methods are applied to source identification and diagnostic of non-stationary sound vibration signals. By checking the coherences for concerned time, this simulation is very well coincident to expected results. The proposed method analyzes the signal instantaneously in both time and frequency domains. The MDSA (Multiple Dimensional Spectral Analysis) analyzes the signal in the plane of instantaneous time and instantaneous frequency at the same time. And it was verified by using the 1500cc passenger car which is accelerated from 70Hz to 95Hz in 4 seconds, the proposed method is effective in determining the vehicle diagnostic problems.

Instantaneous Frequency Estimation of the Gaussian Enveloped Linear Chirp Signal for Localizing the Faults of the Instrumental Cable in Nuclear Power Plant (가우시안 포락선 선형 첩 신호의 순시 주파수 추정을 통한 원전 내 계측 케이블의 고장점 진단 연구)

  • Lee, Chun Ku;Park, Jin Bae;Yoon, Tae Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.987-993
    • /
    • 2013
  • Integrity of the control and instrumental cables in nuclear power plant is important to maintain the stability of the nuclear power plants. In order to diagnose the integrity of the cables, the diagnostic methods based on reflectometry have been studied. The reflectometry is a non-destructive method and it is applicable to diagnose the live cables. We introduce a Gaussian enveloped linear chirp reflectometry to diagnose the cables in the nuclear power plants. In this paper, we estimate the instantaneous frequency of the Gaussian enveloped linear chirp signal by using the weighted robust least squares filtering to localize the impedance discontinuities in the class 1E instrumental cable.

Instantaneous frequency extraction in time-varying structures using a maximum gradient method

  • Liu, Jing-liang;Wei, Xiaojun;Qiu, Ren-Hui;Zheng, Jin-Yang;Zhu, Yan-Jie;Laory, Irwanda
    • Smart Structures and Systems
    • /
    • v.22 no.3
    • /
    • pp.359-368
    • /
    • 2018
  • A method is proposed for the identification of instantaneous frequencies (IFs) in time-varying structures. The proposed method combines a maximum gradient algorithm and a smoothing operation. The maximum gradient algorithm is designed to extract the wavelet ridges of response signals. The smoothing operation, based on a polynomial curve fitting algorithm and a threshold method, is employed to reduce the effects of random noises. To verify the effectiveness and accuracy of the proposed method, a numerical example of a signal with two frequency modulated components is investigated and an experimental test on a steel cable with time-varying tensions is also conducted. The results demonstrate that the proposed method can extract IFs from the noisy multi-component signals and practical response signals successfully. In addition, the proposed method can provide a better IF identification results than the standard synchrosqueezing wavelet transform.

Digital Power Control of LLC Resonant Inverter for Microwave Oven (전자레인지용 LLC 공진형 인버터의 디지털 출력 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.457-462
    • /
    • 2017
  • This paper proposes a digital power control of the LLC resonant half-bridge inverter for high power microwave oven application. Conventional half-bridge inverter for driving a microwave oven uses a hardware-based power control method which varies the frequency according to the AC source voltage. In this case, it is difficult to control the output power according to the variation of the load status of magnetron. The proposed power control consists of an instantaneous current generator and a current controller. Instantaneous current generator makes an instantaneous current reference from power command using input voltage information. Current controller controls input current which has an information of status of magnetron. The proposed power control does not require any compensation algorithm for the change of the load status of the magnetron and change of input voltage. The validity of the proposed method for the control of the change of input voltage and frequency is verified by both simulation and experiment.

A Study Comparing the Effects of Types of Relative Frequency and Delay Internal of Knowledge of Results on Motor Learning (결과에 대한 지식의 상대적 빈도와 지연간격 유형이 운동학습에 미치는 영향 비교)

  • Kim, Dae-Gyun;Cha, Seung-Kyu;Kim, Bum-Gyu;An, Soo-Kyung;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.4 no.1
    • /
    • pp.48-62
    • /
    • 1997
  • Several studies have evaluated the effects of types of relative frequency and delay interval of knowledge of results(KR) on motor skill learning independently. The purpose of this study was to determine more effective types of KR relative frequency and KR delay interval for motor learning. Forty-six healthy subjects (15 female, 31 male) with no previous experience with this experiment participated. The subjects ranged in age from 20 to 29 years (mean=23.9, SD=0.474). All subjects were assigned to one of four groups: a high-instant group, a high-delay group, a low-instant group, and a low-delay group. During the acquisition phase, subjects practiced movements to a target (400 mm) with either a high (83%) or low (33%) KR relative frequency, and with either an instantaneous or delayed (after 8s) KR. Four groups were evaluated on retention (after 3min and 24hr) and transfer (450 mm) tests. The major findings were as follows: (1) there were no between-group differences in acquisition and short-term retention (p>0.05, (2) a low (33%) KR relative frequency during practice was as effective for learning as measured by both long-tenn retention and transfer tests, compared with high (83%) KR practice conditions (p<0.05), (3) delayed (8s) KR enhanced learning as measured by both long-term retention and transfer tests, compared with instantaneous KR practice conditions (p<0.05), and (4) there were no interactions between KR relative frequency and KR delay interval during acquisition, retention, and transfer phases. The results suggest that relatively less frequent and delayed KR are more effective types for motor learning than more frequent and instantaneous KR.

  • PDF

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.718-725
    • /
    • 2009
  • To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.

Characteristics Analysis of Instantaneous Current Resultant Type Load Parallel High Frequency Resonant Inverter (순시전류합성형 부하병렬 고주파 공진 인버터의 특성해석)

  • 조규판;원재선;이봉섭;심광렬;배영호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.293-296
    • /
    • 2002
  • This paper describes the instantaneous current resultant type load parallel high frequency resonant inverter consisting of three unit half-bridge serial and parallel resonant inverter can be used as power source of induction heating. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency($\mu$), load resistance(λ). Experimental results are presented to verify theoretical discussion. This proposed inverter will can be practically used as a power supply in various fields as induction heating application, DC-DC converter etc.

  • PDF