• Title/Summary/Keyword: Installed position

Search Result 681, Processing Time 0.024 seconds

System and method for accurate train stop in manual operation mode (수동운전 모드에서 정위치 정차 방법 및 연동 시스템)

  • Son Young-Jin;Ahn Cheong-Mo;Jeong Dong-Yoon;Park Byoung-No
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1504-1506
    • /
    • 2004
  • The platform screen door(PSD) hasn't been installed yet within the manual operation system, that is, ATS & ATC Signal system. In other countries, it is mostly installed and operated within automatic operation system, that is, ATO. Especially, as a part of the environment friendly system installation, the installation of PSD shall be considered aggressively to improve the air quality in the underground area and to maintain the air-conditioning. Besides the number of suicides in the subway station gets increased these days causing safety hazard, so the installation of PSD is positively reviewed. To install PSD in the manual operation system, it is important to stop the train at the correct position. So we would like to suggest the technical system thereby.

  • PDF

Implementation and measurement of 2.4GHz Plane Antenna (2.4GHz Plane Antenna 제작 및 측정)

  • Kim, Jong-Sung;Choi, Kyung;Eom, Jin-Seop;Cheon, Chang-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1855-1857
    • /
    • 2001
  • An Inverted-F antenna for the 2.4GHz application is designed and implemented. The antenna is implemented on the PCB board and installed in a vertical position. The 10dB characteristics are 2.4 to 2.48GHz in bandwidth which satisfies the bluetooth requirement and the whole impedance is matched. The feed-line on the PCB board is also calculated and implemented. And the measuring system is installed at the KITI in Kangwon Nat'l Univ. and applied to measured the antenna characteristics. The measured values show that this antenna is suitable for the commercial applications.

  • PDF

An evaluation on the sound insulation performance by the install method of asymmetric structure (비대칭 구조의 설치방법에 따른 차음성능평가)

  • Choi, Dool;Moon, Soon-Sung;Goo, Hee-Mo;Kim, Hang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.10-12
    • /
    • 2014
  • In ISO 10140-5:2010, defines the reverberation time conditions of the receiving room. The sound absorption side of test specimen is installed in the source room generally. In this study, examined at the change in the sound insulation characteristics for the test specimen of asymmetric structure attached sound absorbing material by changing the installed position. A difference of sound insulation performance was maxium Rw 1 dB, it is preferable to place the larger sound absorption area in source room.

  • PDF

항공기 ELT 성능 향상 방안 연구

  • An, Cheol-Yong;Yang, Gi-San;Yu, Byeong-Uk
    • 한국항공운항학회:학술대회논문집
    • /
    • 2015.11a
    • /
    • pp.88-91
    • /
    • 2015
  • MISSING Malaysia Airlines flight MH370 has not been discovered and unknown whether it crashed on the ground or under the sea. There are a couple of emergency equipment in the airplane not only outside of airplane but inside airplane such as ELT(Emergency Locator Transmitter). Since the ELT developed, it is required to be installed in the airplane for regulation requirement. However, despite of its important function, it is not working properly or shows wide search range for rescue during the crash or ditching on the water. I would like to propose how to over come the up-to-dated position data just before the event. Connecting with ADIRS or GPS which is installed internal airplane system will help to reduce the rescue time for survival passenger.

  • PDF

Investigation of the Feasibility of a Bus-bar coupled SFCL in the 154 kV KEPCO Grid (154 kV 초전도 한류기 모선연계 적용 연구)

  • 윤용범;현옥배;황시돌;김혜림
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.291-293
    • /
    • 2003
  • Applicability and economical feasibility of a Superconducting Fault Current Limiter (SFCL) have been investigated using the PSS/E simulation for a bus bar coupling at the real 154 ㎸ KEPCO power grid near Seoul. For the investigated substation, the maximum fault current exceeds the interruption rating of 4 circuit breakers (CB) out of 9 installed in the substation. The simulation showed that a SFCL installed in the bus tie position effectively limits the fault currents to save 4 CBs, which are to be replaced by ones of gloater interruption rating, otherwise. We suggest that the optimum resistance of the SFCL be 10 Ohm for the given grid.

  • PDF

A Study on the Design and Control Method for Unmanned Ground Vehicle System (무인 자율 주행 차량 시스템 설계 및 제어에 관한 연구)

  • Moon, Hee-Chang;Park, Myung-Wook;Kim, Jung-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.5
    • /
    • pp.446-455
    • /
    • 2010
  • The research presented covers the design and control method of unmanned ground vehicle (UGV). An electric vehicle is used and is driven by DC motor. The power system on the UGV has been adjusted and actuators have been installed for steering and brake automation. A toggle switch is implemented to easily switch between manual and autonomous states. The UGV state is monitored by a velocity sensor, as well as steering and brake position sensors. An emergency stop device was designed and installed to quickly and safely stop the UGV. Different control methods, including the PID controller, were studied for improved steering responsiveness, and results were confirmed through experimentation. Satisfactory performance was achieved and several possible areas of future research have arisen.

A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House (공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구)

  • 함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

Development of Stewart Platform installed Turntable for Manned Flight Virtual Training Simulator (턴테이블을 적용한 유인비행체 가상훈련 시뮬레이터용 스튜어트 플랫폼 개발)

  • SO, Sangwon;Woo, Jaehoon;Hong, Chunhan
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.125-131
    • /
    • 2020
  • In order to study the correlation between the pilot's cognitive ability and recovery ability by applying a physical element that can cause spatial loss of position to the pilot, a turntable was installed on the top of the motion system to give a quantitative rotational error. We propose a method of simulating flight movement to reduce a difference in feeling and an intuitive method of forward kinematic analysis.

Test Results of Dual-Use Wide-Area Differential GPS System for Extending the Operational Coverage

  • Kap Jin Kim;Jae Min Ahn
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.307-314
    • /
    • 2023
  • Wide-Area Differential Global Positioning System (WADGPS) is a system that operates a number of reference stations to provide correction information to improve the accuracy of GPS users, and it is available to service users within the area where the wide-area reference stations are installed. Recently, as positioning information has been used in various applications, the need for WADGPS for precise navigation in long-distance spaced areas where the wide-area reference stations cannot be installed has been raised. This paper tested the user navigation performance outside the wide-area reference stations of the WADGPS system, which serves both GPS Precise Positioning Service (PPS) and Standard Positioning Service (SPS) users. Static and dynamic tests were conducted using vehicles, and as a result, position accuracy improvement through WADGPS was confirmed even at points hundreds of kilometers outside the network area of the wide-area reference stations. Through this, the performance of the PPS/SPS correction system and the possibility of expanding the service area were confirmed.