Consideration on certification of installation of whole airplane recovery parachute (전기체 낙하산 시스템의 장착에 대한 인증 고려사항)

  • Kim, Seung-Kyem
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.2
    • /
    • pp.22-26
    • /
    • 2016
  • Whole airplane recovery parachute system(WARPS) is a auxiliary safety system to protect occupants in emergency situation where recovery to normal flight condition is impossible. In this paper, application and certification cases of WARPS for Part 23 small airplane is introduced and considerations in certification of the WARPS installed airplane are provided in terms of performance of parachute, function and operation, loads and strength and protection of occupants.

Vessel Tank로 유입되는 폐열회수 처리에 관한 연구

  • Gu, Jae-Ryang
    • 열병합발전
    • /
    • s.66
    • /
    • pp.4-7
    • /
    • 2008
  • When a Combined cycle power plant was started, Steam turbine wasted pure water too much during prewarming of turbine. Wasted pure water gathered in vessel tank and evaporated immediately, then emitted atmosphere. We investigate method to recover the heat in vessel tank. We installed a heat exchanger in vessel tank. In this study, the designing and manufacturing procedures of the heat exchanger was presented. Also, the performance results was showed briefly.

  • PDF

Development of Onboard Power Supply Device for Precision Guided Kit (정밀유도 비행체 탑재용 전원공급장치 개발)

  • Park, Deok-Bae;Kim, Hyung-Shin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.209-214
    • /
    • 2008
  • A precision guided kit is a GPS/INS guided range extension system to improve the accuracy and availability of existing dumb bombs. The PSD(power supply device) installed in the GPS guided kit supplies electrical power to all electrical loads in the kit. In this paper, design process and test results of the PSD have been presented. Additionally, the performance results of the PSD during actual ground and flight tests have been described.

The Report on Test Results of CO Fire Extinguishing System ($CO_2$ 소화설비 구성부품 성능시험보고)

  • Kim, Gi-Ok;Lee, Chan-Ju;An, Byeong-Ho
    • Fire Protection Technology
    • /
    • s.14
    • /
    • pp.5-12
    • /
    • 1993
  • This report is explained about test results of carbon dioxide extinguiching system components and pack-age type system (Kits) for automatic fire extinguishing system. A carbon dioxide system may be used to protect one or more hazards or hazards by menas of directional valves. Package system shall be installed to protect hazards within the limitations. The testing program was progressed by three items, external oppearance test, performance test and Total Flooding Fire Extinguishing System test. The object of this report is present the problem which apperar from the analysis of test results.

  • PDF

A Study of high Efficiency anti-Bacteria Filters for Passenger Car (객차용 고효율 항균 기능성 필터에 관한 연구)

  • 정우성;박덕신;정진도;류해열
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.975-980
    • /
    • 2002
  • We actually installed antibacterial air filter on the air intake route to air conditioner in passenger car and evaluated filters performance on antibacterial effect. And also, antibacterial effect was observed at whole are of filter media by zone of inhibition test. In the evaluation of antibacterial test, it was shown that the air filter has notably sufficient antibacterial efficiency against ordinary filter.

  • PDF

Design of Energy Absorbing Braces (가새형 소성변형감쇠기의 설계 방법에 관한 연구)

  • 김진구;이강준
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.265-272
    • /
    • 2000
  • Unbond brace hysteretic dampers are generally used to prevent or decrease structural damage in buildings subjected to strong earthquake by its energy dissipating hysteretic behavior. According to a previous research, the optimum ratio of device yield strength to story yield strength of the combined system has been identified as the most important parameter for characterizing the performance of this device. In this research, the validity and the applicability of the previous research has been investigated and a new approach has been proposed through earthquake response analysis of a steel structure installed with unbond brace type hysteretic damper.

  • PDF

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

Experimental Study of a Solar Drying System (태양열 건조시스템의 실험적 연구 (I))

  • Lee, K.D.;Lee, N.H.;Auh, P.C.M.
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.14-22
    • /
    • 1987
  • This paper presents an experimental study of a solar drying system designed and installed by KIER. Experiments have been performed using the KIER system for the drying of marine products, such as squid. Presented in detail are the experimental observations of collector air temperature, solar intensity, absorber plate temperature, drying chamber temperature, humidity and other measures of drying chamber performance with variation of air mass flow rate. As a result, average temperature attained in the drying chamber during autumn weather has been adequated for drying of squids.

  • PDF

Flexural Behavior of FRC with Composite Waterproof Sheet (복합방수시트로 보강된 섬유보강콘크리트 휨거동)

  • Kim, Byoungil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.215-216
    • /
    • 2023
  • Leakage in the structure due to the irregular flow of groundwater in the underground structure penetrates into internal spaces such as underground parking lots and basement through underground walls, which is expensive in terms of maintenance of the building. In this study, various composite waterproofing methods installed on the outer walls of underground structures were selected to evaluate the structural performance of composite specimens due to bending behavior through experiments and analysis on bending test behavior on concrete attachment surfaces.

  • PDF

Analysis on Cooling and Heating Performance of Water-to-Water Heat Pump System for Water Source Temperature (물-물 수온차 히트펌프 시스템의 원수온도에 따른 성능 특성 분석)

  • Park, Tae Jin;Cho, Yong;Park, Jin-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • The research assesses the performance of the water-to-water heat pump system installed in Cheongju water treatment plant for cooling and heating ventilation. In summer season monthly averaged COP is ranged from 3.85 to 4.56 according to the water source temperature, and the performance is increased as the raw water temperature is dropped. While, heating performance is increased for the high temperature water source, and the monthly averaged COP is changed from 2.92 to 3.82. The correlation of the water source temperature and the heat pump performance shows a linear tendency by the simple regression of average data. In heating, the COP of heat pump system linearly rises according to the water source temperature. In comparison, the COP in cooling linearly reduces as the raw water temperature is raised. The goodness of fit at the simple regression shows the coefficient of determination 82% in cooling, 46% in heating. The electric cost of water-to-water heat pump is reduced by 40% compared to that of air source heat pump.