• Title/Summary/Keyword: Installed performance

Search Result 2,743, Processing Time 0.035 seconds

The Daylight and Energy Performance Evaluation of Multi-purpose Solar Window System Using Simulaton Program (시뮬레이션에 의한 다기능 복합 솔라윈도우 시스템의 채광과 에너지성능평가)

  • Jeong, Yeol-Wha;Lee, Seun-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.103-110
    • /
    • 2011
  • The aim of this study was to analysis the Heating/cooling performance and Daylighting performance of Solar Window System built in apartments. the solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system. The process of this study is as follows: 1)Solar Window system was designed through the investigation of previous paper and work. 2)The simulation program(Lightscape3.2) was used in daylighting performance analysis. the reference model of simulation was made up to analysis daylighting performance on Solar Window system. 3)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. the reference model of simulation was made up to analysis energy and daylighting performance on Solar Window system. 4)The Size of Simulation model for daylighting and heating/cooling energy analysis was $148.5m^2$ 5)The lighting performance analysis was carried out with various variants, such as the size and installed area of Solar Window system. 6)Energy performance simulation was carried out with various variants, such as Integrated U-value of Solar Window system according to its position, installed angle and insulation thickness. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down at the average of $4.1kWh/m^2$ or 4.2%.

Study on the Evaluation of the Tension and Contact Resistance of a 3 Φ 3 W Plug-In MCCB (3상 3선식 Plug-In MCCB의 인장력 및 접촉저항 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.43-47
    • /
    • 2013
  • The purpose of this paper is to evaluate the performance of a Plug-In MCCB developed for rapid power supply restoration when the MCCB is installed in a power system and to verify its reliability. Since the developed 3 ${\Phi}$ 3 W Plug-In MCCB can be installed on and removed from a bus bar by one touch using a plug housed at the rear, it can be replaced in a short period of time. Therefore, it can quickly respond to the normalization of a power system. When the Plug-In MCCBB is installed on a bus bar, the resistance between each phase and plug was measured to be 0.46 $m{\Omega}$ in average. When the Plug-In MCCB is installed, the tension in the vertical direction was measured to be 112.78 N in average, which is greater than the tension of 50 N specified in the related regulation. The withstanding voltage tests performed 5 times repeatedly by applying 6 kV to the developed Plug-In MCCB for 60 seconds shows good withstanding voltage characteristics. In addition, both the general waterproof test using a water injection method and the insulation resistance analysis using a Mega meter showed good waterproof and insulation characteristics.

Dust Filtration Characteristics of Pleated Filter Bags Installed in CYBAGFILTER® (주름필터를 적용한 CYBAGFILTER®의 여과성능 특성)

  • Park, Young-Ok;Roh, Hak-Jae;Rhee, Young-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.483-491
    • /
    • 2008
  • The filtration characteristics of $CYBAGFILTER^{(R)}$ unit with pleated filter bags were evaluated by comparing the performance of the unit with the lower part of cyclone shape with that of the unit with conventional lower part. Results from the test were also compared with those from the previous research with the $CYBAGFILTER^{(R)}$ in which round filter bags were installed. $CYBAGFILTER^{(R)}$ is the unit which combines the centrifugal separation mechanism and the fabric filtration mechanism in a single unit for efficient removal of particulate matters. The pleated filter bags are made of pleated fabric with an extension of the filtration area about 3 times compared with the conventional round filter bags. The results from the test using pleated filter bags showed an overall collection efficiency of over 99.9% regardless of the shape of lower part installed. When the lower part of cyclone shape was installed, the filter cleaning interval was over 2 times longer compared with that when the conventional lower part was installed. At the same conditions of filtration velocity and filter pressure drop, the $CYBAGFILTER^{(R)}$ with the lower part of cyclone shape, in which the pleated filter bags are installed, can be operated with a flow rate of round 3 times higher than that with conventional round filter bags.

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.

An experimental study on the operating performance of facade installed natural circulation type solar thermal system (수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구)

  • Baek, Nam-Choon;Lee, Wang-Je;Lee, Jin-Kook;Lee, Soon-Myung
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

Evaluation of wireless communication devices for remote monitoring of protected crop production environment (시설재배지 환경 원격 모니터링을 위한 무선 통신 장비 평가)

  • Hur, Seung-Oh;Ryu, Myong-Jin;Ryu, Dong-Ki;Chung, Sun-Ok;Huh, Yun-Kun;Choi, Jin-Yong
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.4
    • /
    • pp.747-752
    • /
    • 2011
  • Wireless technology has enabled farmers monitor and control protected production environment more efficiently. Utilization of USN (Ubiquitous Sensor Network) devices also brought benefits due to reduced wiring and central data handling requirements. However, wireless communication loses signal under unfavorable conditions (e.g., blocked signal path, low signal intensity). In this paper, performance of commercial wireless communication devices were evaluated for application to protected crop production. Two different models of wireless communication devices were tested. Sensors used in the study were weather units installed outside and top of a greenhouse (wind velocity and direction, precipitation, temperature and humidity), inside ambient condition units (temperature, humidity, $CO_2$, and light intensity), and irrigation status units (irrigation flow and pressure, and soil water content). Performance of wireless communication was evaluated with and without crop. For a 2.4 GHz device, communication distance was decreased by about 10% when crops were present between the transmitting and receiving antennas installed on the ground, and the best performance was obtained when the antennas were installed 2 m above the crop canopy. When tested in a greenhouse, center of a greenhouse was chosen as the location of receiving antenna. The results would provide information useful for implementation of wireless environment monitoring system for protected crop production using USN devices.

Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation (외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량)

  • Rhee, Kyu-Nam;Jung, Gun-Joo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

Design of Test Site for Large-Scale Wind Turbine Performance Verification (초대형 풍력터빈 시험을 위한 실증시험장 설계)

  • Sang-Man Kim;Tae-Yoon Jeong;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.397-404
    • /
    • 2023
  • This paper designs a wind turbine test site based on international regulations for the certification of wind turbine prototypes. The maximum height of the meteorological mast installed at the test site is 140m, and power facilities capable of testing up to three wind turbines of 5MW or more are installed. The weather resources measured at the mast can be recorded and analyzed using a monitoring system. Wind turbine manufacturers can use this test site during the certification period, and the installed wind turbines can be used for continuous power generation projects. Therefore, this test site can provide fundamental data for measuring the long-term performance and durability of wind turbines, which can be used to improve models or develop new wind turbines.

Heating Performance of a Ground Source Heat Pump System through Actual Operation (지열원 히트펌프시스템의 실사용을 통한 난방성능연구)

  • Koo, Kyoung-Min;Jeong, Young-Man;Hwang, Yu-Jin;Lee, Jae-Keun;Jang, Se-Yong;Kim, In-Kyu;Jin, Sim-Won;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1341-1346
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

Heating Performance of a Ground Source Heat Pump System through Actual Operation (지열원 히트펌프시스템의 실사용을 통한 난방성능연구)

  • Koo, Kyoung-Min;Jeong, Young-Man;Hwang, Yu-Jin;Lee, Jae-Keun;Jang, Se-Yong;Kim, In-Kyu;Jin, Sim-Won;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.788-793
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF