• 제목/요약/키워드: Installed base

검색결과 345건 처리시간 0.022초

창덕궁 선정전의 의례 공간적 건축 구조 (The Architectural Structure of Seonjeong-jeon in Changdeok Palace as a Ceremonial Hall)

  • 이종서
    • 건축역사연구
    • /
    • 제29권2호
    • /
    • pp.39-52
    • /
    • 2020
  • Seonjeong-jeon, the semi-great hall in Changdeok Palace, was constructed in a highly formal and conservative style and accommodated official ceremonies. However, the contemporary modification of the building has distorted or eliminated features including the two side doors on the front, the floor coverings, and the throne base (Jwa-tap) that consisted the most significant part of the throne. Seonjeong-jeon originally had three doors that stood between each pair of columns on the front side, respectively. The courtiers accessed the building through the side doors, while the central door was exclusively designated for the king. However, the renovation in 1999 ignored the political context of the architectural form of the building and changed the side doors into windows, damaging the traditional structure inherited from the early Joseon Dynasty. Although the building currently has traditional wooden floor structure (Woomul-maru), it was originally covered with square brick tiles (Bang-jeon) before the Japanese occupation, following the customs of early Joseon Dynasty. The throne was placed to the north of the central door and consisted of the throne base and a decorative roof (Dang-ga). A canvas (Jang-ja), which featured the royal symbolic painting of Sun, Moon, and Five Peaks, was also installed between the two columns that connected the base and the roof. Nevertheless, only the columns and the blank canvas remain nowadays after the removal of the base.

DSRC 기반의 ETCS 기지국 안테나 설계 및 제작 (Design and Fabrication of Base Station Antenna for ETCS based on DSRC)

  • 고진현;김남기;하재권
    • 한국ITS학회 논문지
    • /
    • 제3권1호
    • /
    • pp.75-83
    • /
    • 2004
  • 본 논문에서는 ITS 서비스 구성 요소 중의 하나인 ETCS(Electronic Toll Collection tsystem)에서 RSE(Road Side Equipment) 기지국 gantry에 장착되어 이동체와 무선 통신 링크를 연결해 주는 ETCS 기지국유 안테나를 설계 및 제작하고 그 특성을 측정하였다. ETCS 기지국용 안테나 특성은 적은 부엽 특성과 도로 상황과 이동체 탑재되는 OBU 위치에 따라 특정 형태의 빔 패턴이 요구된다. 또한 반사에 의한 multipath 신호 영향을 최소화하기 위해 원형편파 특성이 요구된다. 저 부엽의 빔 패턴을 얻기 위해 배열 패치 구조와 Taylor distribution에 의한 방사요소의 전류 weighting factor를 적용하였다. 제작된 안테나의 동작 중심 주파수는 5.8GHz이고, 반사손실은 -10 dB를 기준으로 130 MHz, 10MHa사용 대역내에서 축비 2.6 dB이하의 RHCP 편파 특성과 17 dBi 이득을 얻었으며, 빔 패턴은 시뮬레이션 결과와 측정 결과가 잘 일치하고 있음을 보여주었다.

  • PDF

전주시 BIS 기지국용 안테나 제작 및 활용 (Fabrication and Application of BIS Base Station Antenna in Jeon-Ju City)

  • 고진현;박주문;하재권;박덕규
    • 한국ITS학회 논문지
    • /
    • 제3권2호
    • /
    • pp.95-104
    • /
    • 2004
  • 본 논문에서는 ITS 서비스 구성 요소 중의 하나인 BIS(Bus Information System)의 기지국용 전방향성 안테나를 설계 및 제작하고 그 특성을 측정하였다. 제작된 BIS 기지국용 안테나는 전주시 도심의 주요 교차로의 신호등 gantry에 설치된다. 통신 영역이 차선의 개수와 교차로 크기, 도로의 방향에 따라 상이한 경우에도 요구된 통신 성능을 얻기 위해 최대 100m 통신 영역을 화보하기 위해 10dBi 정도의 고 이득이 요구된다. 이를 위해 OMA(Omni-directional Planar Microstrip Antenna)를 배열한 구조를 적용하였다. 제작된 안테나의 동작 중심 주파수는 5.8GHz이고, 반사손실은 -10 dB를 기준으로 640MHz 이상, 이득은 10.3dBi를 얻었으며, 빔 패턴은 전방향성으로 시뮬레이션 결과와 측정 결과가 유사하게 나타나고 있다.

  • PDF

Base Isolation System이 있는 건물의 지진하중에 대한 동적해석 (Semismic Analysis of Building Structures with Base Isolation System)

  • 이동근;이정석
    • 전산구조공학
    • /
    • 제3권1호
    • /
    • pp.71-81
    • /
    • 1990
  • Base isolation system은 구조물의 기초하부에 설치되며 지진에 의한 구조물의 피해를 감소시켜 준다. 지금까지 많은 공학들에 의해 여러가지 base isolation system이 개발되었으나 실용화된 것은 1970년대에 laminated rubber bearing(LR type)이 개발되고서부터 였다. 최근에는 laminated rubber bearing밑에 미끄럼판을 둔 새로운 base isolation system(SR type)이 개발되었다. 본 연구에서는 isolation system과 구조물의 여러가지 성질에 따른 isolation효과에 대한 연구를 수행하였다. 이 연구의 결과, isolaion system은 지진하중이 작용할 때 건물에 발생하는 피해를 상당히 감소시킴을 알 수 있으며, isolaion system의 주기가 길어짐에 따라 isolation효과는 증가함을 알 수 있다. 그리고 건물의 높이가 증가함에 따라 isolation효과는 줄어든다는 것을 알 수 있다. SR type isolation system이 있는 건물에 지진하중이 작용할 때, 건물내부에서 발생하는 가속도와 층간변위, 그리고 전체변위는 LR type의 경우보다 작으므로 보다 효율적이라는 것을 알 수 있다.

  • PDF

다중 대역용 차세대 이동통신 기지국 시스템의 전력 및 탄소배출량 절감효과 분석 (The Analysis of Reducing Power Consumption and CO2 Emission in the Advanced Mobile Communication Base Station)

  • 오승곤;안준오;김부균
    • 한국통신학회논문지
    • /
    • 제36권6B호
    • /
    • pp.642-649
    • /
    • 2011
  • 본 논문은 다중 대역에서 동작하는 안테나를 장착한 차세대 이동통신 기지국 시스템의 도입 가능성 분석을 위해 종래의 기지국 시스템과 케이블 손실전력을 고려한 차세대 기지국 시스템의 전력 손실 및 탄소 절감효과를 분석하였다. 차세대 기지국 시스템은 옥외에 무선처리부를 설치하고, 옥내의 기저대역처리부는 광케이블로 연결하여 종래의 기지국에서 케이블로 인해 발생하는 전력손실을 없애는 구조이다. 본 연구 결과 종래의 기지국과 비교하여 동일한 서비스 커버리지 확보가 가능하고, 케이블 전력손실이 5 dB 줄어든 차세대 기지국 시스템을 도입할 경우 CDMA 20W, WCDMA 30W, WiBro 10W 기지국에서 소모하는 전력량은 연간 155,078 MWh에서 49,038 MWh로 감소시킬 수 있으며, 탄소배출량 또한 65,878 $tCO_2$에서 20,832 $tCO_2$로 절감됨을 확인하였다. 따라서 차세대 기지국 시스템은 그린 IT 기술로 이용 가능할 것으로 고찰되었다.

대향류식 배기열 회수장치의 가솔린기관 적용 특성에 관한 연구 (Study on the Apply Characteristics to the Gasoline Engine of Exhaust Heat Recovery Device Counterflow)

  • 신석재;김종일;정영철;최두석
    • 한국자동차공학회논문집
    • /
    • 제21권4호
    • /
    • pp.153-158
    • /
    • 2013
  • The purpose of this study is to investigate the performance characteristics of the counterflow exhaust heat recovery device for the applied gasoline engines. The EHRS device is installed behind the catalyst. This study investigates the engine warm-up characteristic, the exhaust noise characteristic, the back-pressure characteristic. The engine warm-up characteristics is (load 0%, load 10%, load 20%) in (idle, 1000rpm, 1500rpm, 2000rpm, 2500rpm) conditions by measuring the time it warmed up, coolant temperature ($25^{\circ}C{\sim}80^{\circ}C$) until the performance evaluation is performed. The wide open throttle and the coast down the exhaust noise and the back-pressure characteristic experiment repeated twice. The test conditions is 950rpm~6,050rpm proceed experiment repeated 3-5 times. Load 0% idle conditions except the results improved engine warm-up characteristics. The exhaust noise obtain similar results the BASE+EHRS W/O_FRT_MUFF with BASE and back-pressure to obtain similar results BASE+EHRS W/O_FRT_ MUFF with BASE+EHRS.

A new base plate system using deformed reinforcing bars for concrete filled tubular column

  • Park, Yong-Myung;Hwang, Won-Sup;Yoon, Tae-Yang;Hwang, Min-Oh
    • Steel and Composite Structures
    • /
    • 제5권5호
    • /
    • pp.375-394
    • /
    • 2005
  • An experimental study was conducted to develop a new base plate anchorage system for concrete filled tubular column under an axial load and a moment. The column was connected to a concrete foundation using ordinary deformed reinforcing bars that are installed at the inside and outside of the column. In order to investigate the moment resisting capacity of the system, horizontal cyclic loads are applied until the ultimate condition is reached with the axial load held constant. To derive a design method for moment resisting capacity, the reinforced concrete section approach was investigated with the assumption of strain compatibility. The results by this approach agreeded well with those of experiments when the bearing pressure of confined concrete and tangent modulus of steel bars are assumed appropriately. Also, it was found that the column interaction curve can be used to predict the yield strength of the base plate system.

매입기초와 토질에 따른 인발저항력 특성 (Characteristics of Uplift Capacity of a Embedded Foundation and Soil Type)

  • 임성윤;김유용;유석철;김명환
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.23-30
    • /
    • 2019
  • In this study, we evaluated the applicability of proper embedded depth of fillings by examining the uplift resistance using spiral foundation and top base foundation. As a result of the model test, the maximum uplift resistance increased with the embedded depth. The maximum uplift resistance of each region was found to be 50cm depth. The spiral foundation was 335.14N of Sancheong, 312.32N of Seongju, 403.94N of Wanju, and the top base foundation was 745.06N of Sancheong, 1028.82N of Seongju and 950.76N of Wanju. The yield point after the elastic section in the stress-displacement graph of the top base foundation was calculated as the maximum uplift resistance. For this reason, farmers do not actually use top bases foundation. Therefore, it was considered that the additional load increase due to slip connector will not occur. Model test results show that the maximum uplift resistance increases with the purlinss installed under the ground. Therefore, additional comparative studies through purlins installation will be needed.

Extensometers results correction in concrete dams: A case study in RCC Zhaveh Dam

  • Ziaei, Ahad;Ahangari, Kaveh;Moarefvand, Parviz;Mirzabozorg, Hasan
    • Structural Monitoring and Maintenance
    • /
    • 제4권1호
    • /
    • pp.17-31
    • /
    • 2017
  • Since extensometers are used to determine the absolute deformation of foundation and abutments and all results are obtained in reference to the base rod, the accuracy of these results has been constantly a subject of debate. In this regard, locating and installing extensometers outside the range of effect zone is also another challenge. The main purpose of this paper is to investigate and modify extensometers results based on the mentioned issues. For this aim, the concrete RCC Zhaveh dam in Iran was selected as the case study. To study the results of extensometers installed in this dam, first, the 3DEC_DP 5.00 software was applied for numerical modeling. Parameters such as discontinuities, dead load and piezometric pressure in the interface of concrete and rock were considered. Next, using the results obtained from 6 extensometers in foundation and abutments and 4 clinometers in dam body, the numerical model was calibrated through back analysis method. The results indicate that the base rod is moved and is not recommended being used as the base point. In other words, because installation of base anchor outside the range of effect zone is not possible due to the operational and economic considerations, the obtained results are not accurate enough. The results indicate a considerable 2-3 mm displacement of the base rod (location of the base anchor) in reference to the real zero point location, which must be added to the base rod results.

강관 부착 PHC파일로 시공된 매입말뚝의 선단지지력 산정 (Calculation of Base Load Capacity of Bored Pre-cast Piles Using New PHC PIles with Steel Pipe at Pile Toe)

  • 백규호
    • 한국지반공학회논문집
    • /
    • 제32권9호
    • /
    • pp.5-16
    • /
    • 2016
  • 풍화암에 근입된 매입말뚝의 선단지지력을 증대시키기 위해 파일 선단에 짧은 길이의 강관을 부착한 새로운 PHC파일이 개발되었다. 본 연구에서는 새로운 PHC파일로 시공된 매입말뚝의 선단지지력 특성을 정량적으로 파악하기 위하여 지반조건이 다른 7개 현장에 새로 개발된 매입말뚝을 시공하고 정재하 및 동재하시험을 수행하였다. 그리고 정재하 시험에서 얻어진 결과에 근거해서 새로운 PHC파일로 시공된 매입말뚝의 선단지지력을 산정하기 위한 경험식을 제안하였다. 현장에서 측정된 선단지지력과 지지력 산정식으로부터 계산된 선단지지력을 비교한 결과 기존 지지력 산정식은 새로운 PHC파일로 시공된 매입말뚝의 선단지지력을 상당히 과소평가하는 반면 제안된 경험식은 새로운 PHC파일로 시공된 매입말뚝의 선단지지력을 안전측에서 산정하는 것으로 나타났다.