• Title/Summary/Keyword: Installation stability

Search Result 542, Processing Time 0.034 seconds

Trends in Electromagnetic Compatibility (EMC) Technology to Secure Electromagnetic Safety in the Critical Facilities (주요시설의 전자파 안전성 확보를 위한 전자파적합성(EMC) 기술)

  • Kwon, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.3
    • /
    • pp.41-50
    • /
    • 2018
  • In order to ensure the electromagnetic safety of a complex facility equipped with a variety of electric and electronic equipment, the European Union (EU) has enacted and applied the Electromagnetic Compatibility Directive (EMC Directive 2004/108/EC) to a fixed installation. This paper introduces the regulations and techniques related with electromagnetic compatibility (EMC) engineering applied to a fixed installation, which is used to prevent a malfunction of critical equipment and systems caused by unwanted electromagnetic waves and to operate the facilities with stability.

A Study on the Overcurrent Relay Coordination in Power Systems (전력계통에서의 과전류계전기 보호협조에 관한 연구)

  • Choi, Hong-Kyoo;Kim, Kyung-Chul;Oh, Jung-Suk;Kim, Byung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

Economic Analysis of Energy Storage System for power system (전력계통에 설치되는 에너지 저장장치의 경제성 분석)

  • Choi, Joon-Young;Lee, Jong-Hyun;Ahn, Jong-Wook;Ko, Won-Suk;Hong, Jun-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.92-96
    • /
    • 2009
  • In this paper, economic analysis of Energy Storage System for power system is performed. Economic analysis is performed to show the benefits of Energy Storage System. Results illustrate the advantages of Energy Storage System not only acting as an alternative generation resource but also giving a better reliability and stability in power system.

  • PDF

Real Time Wide Area Voltage Stability Index in the Korean Metropolitan Area

  • Han, Sang-Wook;Lee, Byong-Jun;Kim, Sang-Tae;Moon, Young-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.451-456
    • /
    • 2009
  • Through the development of phasor measurement units (PMU), various aspects of power system dynamic behavior could be monitored and diagnosed. Monitoring dynamic voltage stability has become one of the achievements we can obtain from PMUs. It is very important to select the most appropriate method for the Korea Electric Power Corporation (KEPCO) system since there are many voltage stability indices. In this paper, we propose an advanced WAVI (Wide Area Voltage Stability) that is well suited for the purposes of monitoring the dynamic voltage stability of KEPCO's PMU installation plan. The salient features of the proposed index are: i) it uses only PMU measurements without coupling with EMS data; ii) it is computationally unburdened and can be applied to real-time situations. The proposed index is applied to the KEPCO test system and the results show that it successfully predicts voltage instability through comparative studies.

An Experimental Study on the Stability of Artificial Reefs for Shellfish and Seaweed (패조류용 어초의 안정성에 관한 실험적 연구)

  • Sohn, Byung-Kyu
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.120-124
    • /
    • 2007
  • The purpose of this study was to investigate the stability of the arched and fan types of artificial reefs, which provide habitats for shellfish and seaweed. According to the Froude similitude, parameters affecting the stability of the artificial reefs were analytically, experimentally studied. First, the design parameters of the artificial reefs in wave and current fields were presented. Then, using dimensionless parameters, such as the surf similarity parameter and water particle speed, the stability of the arched and fan types of artificial reefs was investigated. From the hydraulic experiments, it is shown that the stability heavily depends on the way the artificial reefs are installed. Therefore, the installation of the artificial reefs on the surf zone should be carefully executed.

A Study on the Optimal Parameter Selection of a Power System Stabilizer and Power Converters for HVDC Linked System (HVDC 연계 시스템의 전력계통 안정화 장치와 전력변환기 적정 파라미터 선정에 관한 연구)

  • 조의상;김경철;최홍규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.65-72
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. Control of HVDC converter and inverter are used a constant current loop. Proper parameters of PI controllers are obtain based on the Root-locus technique in other to have sufficient speed and stability margin to cope with charging reference values and disturbance. The small signal stability arid transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the studycase system is adequately damped. Also the simulation results using the HVDC converter and inverter parameters obtained from this proposed method show proper current control characteristics. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

Contingency Analysis for Small Signal Stability of Power Systems (전력계통의 미소신호안정도 상정사고 해석)

  • 심관식;김용구;문채주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.127-137
    • /
    • 2003
  • Contingency analysis is one of the most important tasks encountered by planning and operation of lafe scale power systems. This paper describes a new contingency analysis methods for small signal security assessment based on the eigen-sensitivity/perturbation of the electromechanical oscillation modes. The eigen-sensitivity/perturbation with respect to line suceptances and controller parameters can he used to find possible sources of the system instability, and to select contingency for small signal stability. Also, the contingency selection to identify critical generators for MW changes can be obtained by computing the relative movement of the system oscillation modes. The proposed algorithm has been successfully tested on the KEPCO systems which is comprised of 791-bus, 1575-branch and program PSS/E

Stability Improvement of Output Voltage Control on the Power Supply for Railways (전동차용 전원장치의 출력전압 제어 안정성 향상)

  • 서광덕
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.134-141
    • /
    • 1999
  • Ths paper describes on the stability improvement of output voltage control on the power suwJy for railway. On the transient states such as input voltage sudden change, the inpJt and output voltage beccxre unstable by L-C resonance occurred due to constant output voltage control. In this paper, the new clamping circuit for system stability is proposed, and control method using band attenuated filter and feed-forward terms is introduced. The propoesd damping circuit is composed with sma1l size R-L. Also, the 3 level PWM method is adopted to decrease distortion of output voltage. The output voltage is controlledl with variation under 10% without oscillation at transient states and have total hanmnic distortion under 3%.der 3%.

  • PDF

A Practical Exciter Model Reduction Approach For Power System Transient Stability Simulation

  • Kim, Soobae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.89-96
    • /
    • 2015
  • Explicit numerical integration methods for power system transient stability simulation require very small time steps to avoid numerical instability. The EXST1 exciter model is a primary source of fast dynamics in power system transients. In case of the EXST1, the required small integration time step for entire system simulation increases the computational demands in terms of running time and storage. This paper presents a practical exciter model reduction approach which allows the increase of the required step size and thus the method can decrease the computational demands. The fast dynamics in the original EXST1 are eliminated in the reduced exciter model. The use of a larger time step improves the computational efficiency. This paper describes the way to eliminate the fast dynamics from the original exciter model based on linear system theory. In order to validate the performance of the proposed method, case studies with the GSO-37 bus system are provided. Comparisons between the original and reduced models are made in simulation accuracy and critical clearing time.

Physical stability of arginine-glycine-aspartic acid peptide coated on anodized implants after installation

  • Huh, Jung-Bo;Lee, Jeong-Yeol;Jeon, Young-Chan;Shin, Sang-Wan;Ahn, Jin-Soo;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.84-91
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. MATERIALS AND METHODS. Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density. Two pieces of artificial bone were fixed in a customized jig, and coated implants were installed at the center of the boundary between two pieces of artificial bone. The test groups were classified as: P-H, P-S, C-H, or C-S. After each installation, implants were removed from the SRPF, and the residual amounts and rates of RGD peptide in implants were measured by fluorescence spectrometry. The Kruskal-Wallis test was used for the statistical analysis (${\alpha}$=0.05). RESULTS. Peptide-coating was identified by fluorescence microscopy and XPS. Total coating amount was higher for physical adsorption than chemical grafting. The residual rate of peptide was significantly larger in the P-S group than in the other three groups (P<.05). CONCLUSION. The result of this study suggests that coating doses depend on coating method. Residual amounts of RGD peptide were greater for the physical adsorption method than the chemical grafting method.