• Title/Summary/Keyword: Installation space

Search Result 898, Processing Time 0.044 seconds

A Study on the Preference of Fluorescent Lamp and White LEDs by the Comparison of Color Temperature in a Office Space (사무공간에서 형광램프 조명기구와 백색 LED 조명기구의 색온도 비교를 통한 선호도에 관한 연구)

  • Jung, Yeon-Hong;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.3-6
    • /
    • 2008
  • The purpose of this study is to investigate the luminous environment of fluorescent lamp and LED lamp in a office space for various color temperature by subject response test. For this, three different color temperatures were tested for the same illuminance level. Based on such test results for various color temperatures of fluorescent lamp and white LEDs, this study is to analyze the preferences of color temperature and light source, and perceptional brightness of each light source and color temperature. Then, this study is to derive the guidelines for the performance of color temperature which are suitable on the purpose and the mood of a office space.

  • PDF

A Study on System of Object Recognition Using Ultrasonic Sensor (초음파 센서를 이용한 물체 인식 시스템에 관한 연구)

  • 조현철;이기성
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.74-82
    • /
    • 1998
  • In this study, system of object recognition independent of translation and rotation using ultrasonic sensor and neural network is presented. The object recognition rate is 92.3[%] in spite of changing output neuron space size of SOFM neural network from$4\times4 to10\times10$and iteration from 10 to 50. The experimental results show that the proposed system of object recognition can be applied to the object recognition field of intelligent robot.

  • PDF

Study on Development of Light Duct System for Perimeter Occupied Zone on Underground Space (지하대공간에 있어 Perimeter Occupied Zone에 대한 채광덕트 시스템 개발에 관한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.21-26
    • /
    • 1999
  • Using daylight in underground spoce may significantly reduce electric lighting load and give a visually comfortable environment. This reper describes a fundaIrentaI study on light duct system to predict inter illuminance ratio on underground periIreter occupied zone level. As a result, integral equation for inter-reflection program are developed and by using optimize light duct system can gives daylight on deep underground space. space.

  • PDF

A Novel Fractal-Space Multiplexing using Moving Window and Double-Focusing Lens (움직이는 창과 이중 초점 렌즈를 이용한 프랙탈-공간 다중화 기법)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.1-6
    • /
    • 2002
  • We propose a novel fractal-space multiplexing holographic memory system using moving window and double-focusing lens, which can eliminate crosstalk due to two neighboring moving window rows in the vertical direction of the conventional moving window holographic memory system, and demonstrated its feasibility through optical experiments.

Installation of Induced Current Measurement Systems in Substations and Analysis of GIC Data during Geomagnetic Storms

  • Choi, Kyu-Cheol;Park, Mi-Young;Ryu, Youngsoo;Hong, Youngsu;Yi, Jong-Hyuk;Park, Sung-Won;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.427-434
    • /
    • 2015
  • Coronal Mass Ejections (CME), which originate from active regions of the Sun's surface, e.g., sunspots, result in geomagnetic storms on Earth. The variation of the Earth's geomagnetic field during such storms induces surface currents that could cause breakdowns in electricity power grids. Hence, it is essential to both monitor Geomagnetically Induced Currents (GICs) in real time and analyze previous GIC data. In 2012, in order to monitor the variation of GICs, the Korean Space Weather Center (KSWC) installed an induced current measurement system at SINGAPYEONG Substation, which is equipped with 765 kV extra-high-voltage transformers. Furthermore, in 2014, two induced current measurement systems were installed on the 345 kV high-voltage transformers at the MIGEUM and SINPOCHEON substations. This paper reports the installation process of the induced current measurement systems at these three substations. Furthermore, it presents the results of both an analysis performed using GIC data measured at the SINGAPYEONG Substation during periods of geomagnetic storms from July 2013 through April 2015 and the comparison between the obtained GIC data and magnetic field variation (dH/dt) data measured at the Icheon geomagnetic observatory.

Decision of the Luminous Intensity Distribution and Design of fluorescent Luminaire Based on Space Features of the Intelligent Building (인텔리전트 빌딩의 공간특성을 고려한 배광결정과 형광등기구 설계)

  • Lee, Jung-Wook;Kim, Hong-Bum;Han, Jong-Sung;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.10-17
    • /
    • 2001
  • We need to how about activity types, lighting conditions and physical features in a plate that is a object for the reasonable and economic lighting design. Thus, lighting designer analyzes spare features and completes lighting design by using luminaire that has a suitable luminous intensity distribution. There are special data in this study from analysing about activity types, lighting conditions and physical features of intelligent buildings that are getting an essential infrastructure in the information society. Intelligent building could be classified with office space, passing space, high ceiling space, one-side working space for the analysis. Also, four luminous intensity distributions and fluorescent fixtures, which are the mutt used luminaires in office building, are designed from the data of intelligent building.

  • PDF

A Study on Utilization of Apartment Rear Veranda (아파트 후면 베란다의 이용실태에 관한 연구)

  • 김수양
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.86-93
    • /
    • 1998
  • An Apartment Veranda is a transitive space which is being used for many different purpose. A Rear Veranda which is connected to the kitchen is an important space for the housekeeping work and it should be planned carefully to reflect the rational and functional designs. Therefore the objective of this research is to suggest a systematic basis for the practical space planning of the Rear veranda that meets the varied needs of consumers by examining its usage pattern through the analysis of the apartment occupant's behavior pattern stored item the degree of satisfaction and consumer requirements. The research was conducted mainly on apartments built after 1990. The following are the conclusions from the research : 1. Most of the research respondents were aware of the absolute need for the Rear veranda. But they expressed dissatisfaction with the space usage. This indicates that the Rear Veranda planning does not reflect the functionality of the space and concentrates on the idea of providing consumers a service space based on the size of the apartment instead. 2. Although the Rear veranda is used as the multipurpose housework space it is mainly used as the laundry and storage space. This shows a big deviation from the concept of the utility space. Because the behavior pattern associated with the Rear Veranda is largely influenced by the traditional life pattern the development of the Rear Veranda as an exclusive space for the housekeeping work. 3. According to a high frequency of the storage of the laundry related item in the Rear Veranda indicated by the research the Rear veranda is used as the laundry room as well as a auxiliary storage space by most people. The installation of gas range is expected to increase due to the expansion of the usage function of the Rear Veranda space. The installation of a specialized refrigerator to store the traditional food is demanded. 4. Consumers need more efficient and functional storage device because the temporary shelves are often being used as the storage device. The perception of the storage device is assumed to have been influence by the traditional life style.

  • PDF

A Study on Improvement of the Standards for the Manoeuvring space at Doors (출입문 측면 활동공간 설치기준 개선에 관한 연구)

  • Shin, Dong-Hong;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.71-79
    • /
    • 2019
  • Purpose: The manoeuvring space at doors must be secured for users of walking aids, wheelchair users, stroller users, luggage carriers, etc., so clear criteria must be established. The korean standards for the manoeuvring space at doors need to be improved to present clear criteria depending on the type of entrance and the direction of opening and closing. Method: Korean standard, International Standard(ISO 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(OENORM B 1600, 2017) and Swiss Standard(Norm SIA 500, 2009) were investigated and analyzed. A comprehensive improvement of the criteria for the manoeuvring space at doors is proposed. Results: The manoeuvring space at doors, which is essential for the disabled to use the door, shall be installed with a comprehensive consideration of the width of doors, the Circulation space, the direction of access, and the method of opening and closing of the door. Korean standards, such as the width of doors, the Circulation space, and the manoeuvring space at doors, are different from international and international standards, which require improvement of standards. The criteria for the manoeuvring space at doors shall be clearly improved so as not to be misinterpreted during the installation of doors and the BF-certification. Implication: The criteria for the installation of doors shall be presented as a comprehensive alternative through continued study of details. In addition, improvements in standards that reflect changes in international standards should be made.

Performance Improvement of Near Earth Space Survey (NESS) Wide-Field Telescope (NESS-2) Optics

  • Yu, Sung-Yeol;Yi, Hyun-Su;Lee, Jae-Hyeob;Yim, Hong-Suh;Choi, Young-Jun;Yang, Ho-Soon;Lee, Yun-Woo;Moon, Hong-Kyu;Byun, Yong-Ik;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • We modified the optical system of 500 mm wide-field telescope of which point spread function showed an irregularity. The telescope has been operated for Near Earth Space Survey (NESS) located at Siding Spring Observatory (SSO) in Australia, and the optical system was brought back to Korea in January 2008. After performing a numerical simulation with the tested value of surface figure error of the primary mirror using optical design program, we found that the surface figure error of the mirror should be fabricated less than root mean square (RMS) $\lambda$/10 in order to obtain a stellar full width at half maximum (FWHM) below $28\;{\mu}m$. However, we started to figure the mirror for the target value of RMS $\lambda$/20, because system surface figure error would be increased by the error induced by the optical axis adjustment, mirror cell installation, and others. The radius of curvature of the primary mirror was 1,946 mm after the correction. Its measured surface figure error was less than RMS $\lambda$/20 on the table of polishing machine, and RMS $\lambda$/15 after installation in the primary mirror cell. A test observation performed at Daeduk Observatory at Korea Astronomy and Space Science Institute by utilizing the exiting mount, and resulted in $39.8\;{\mu}m$ of stellar FWHM. It was larger than the value from numerical simulation, and showed wing-shaped stellar image. It turned out that the measured-curvature of the secondary mirror, 1,820 mm, was not the same as the designed one, 1,795.977 mm. We fabricated the secondary mirror to the designed value, and finally obtained a stellar FWHM of $27\;{\mu}m$ after re-installation of the optical system into SSO NESS Observatory in Australia.