• Title/Summary/Keyword: Installation criteria

Search Result 298, Processing Time 0.037 seconds

The optimized standards and criteria for installing switches on distribution feeder (국내 배전계통의 최적 개폐기 설치 기준(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

A Study on Optimal Site Selection for the Artificial Recharge System Installation Using TOPSIS Algorithm

  • Lee, Jae One;Seo, Minho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.2
    • /
    • pp.161-169
    • /
    • 2016
  • This paper is intended to propose a novel approach to select an optimal site for a small-scaled artificial recharge system installation using TOPSIS (Technique for Order Preference by Similarity to Ideal Solution) with geospatial data. TOPSIS is a MCDM (Multi-Criteria Decision Making) method to choose the preferred one of derived alternatives by calculating the relative closeness to an ideal solution. For applying TOPSIS, in the first, the topographic shape representing optimal recovery efficiency is defined based on a hydraulic model experiment, and then an appropriate surface slope is determined for the security of a self-purification capability with DEM (Digital Elevation Model). In the second phase, the candidate areas are extracted from an alluvial map through a morphology operation, because local alluvium with a lengthy and narrow shape could be satisfied with a primary condition for the optimal site. Thirdly, a shape file over all candidate areas was generated and criteria and their values were assigned according to hydrogeologic attributes. Finally, TOPSIS algorithm was applied to a shape file to place the order preference of candidate sites.

Reflector Design for LED Pedestrian Lighting Using Indirect Reflectance Type (간접 반사 방식의 LED 보안등기구 반사판 설계)

  • Chae, Sung-Gi;Jung, Dong-Hwan;Lee, Yoon-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.6-13
    • /
    • 2012
  • In this paper, we took an indirect reflectance type that irradiates light from an LED module, which reflects light from a reflector onto the road. This LED pedestrian lighting design produces minimal glare from a relatively simple structure. Using LightTools 7.2, we conducted a study on the varying shape and curvature of the reflector. In order to further investigate this data, we researched the ratio of the DLOR and ULOR, the average illuminance, and the uniformity of the illumination. Based on this research, we selected optimum conditions to realize the actual LED pedestrian lighting using RELUX software. We found the average illuminance value to be 22[1x] and the illuminance uniformity ratio to be 0.23, which met the criteria of the proposed standards set in KS C 7658. In addition, it also satisfied the criteria of the standards set in KS A 3701 by having TI (Threshold Increment) at 7[%].

Thermo-structural monitoring of RCC dam in India through instrumentation

  • Ashtankar, V.B.;Chore, H.S.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.95-113
    • /
    • 2015
  • The knowledge of the behavior of any roller compacted concrete (RCC) dam and its foundation is gained by studying the service action of the dam and its foundation using measurements of an external and internal nature. The information by which a continuing assurance of structural safety of the RCC dam can be gauged is of primary importance. Similarly, the fact that the information on structural and thermal behavior and the properties of concrete that may be used to give added criteria for use in the design of future RCC dams is of secondary importance. Wide spread attention is now being given to the installation of more expensive instrumentation for studying the behavior of concrete dams and reservoirs and forecasting of any adverse trends. In view of this, the paper traces installation and need of the comprehensive instrumentation scheme implemented to monitor the structural and thermal behavior of 102.4 m high RCC dam constructed near Mumbai in India. An attempt is made in the present paper to emphasize the need to undertake an instrumentation program and evaluate their performance during construction and post construction stage of RCC structures. Few typical results, regarding the thermal and structural behavior of the dam, obtained through instrumentation installed at the dam site are presented and compared with the design considerations. The fair agreement is seen in the response observed through instrumentation with that governing the design criteria.

A Study on the Criteria for Applying the Obstacle Limitation Surface of the UAM Vertiport (UAM 수직이착륙장(Vertiport)의 장애물제한표면 적용 기준에 대한 연구)

  • TaeJung Yu
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.31 no.1
    • /
    • pp.18-25
    • /
    • 2023
  • In recent years, UAM (Urban Air Mobility) has emerged as a solution to these urbanization problems, and many related reports and diverse prospects have been reported. UAM flights are planned to take off and land at a Vertiport located in the city center and fly along a pre-established corridor. In order for UAM to operate safely in the city center, it must ensure a safe flight path that avoids the buildings in the city center and many surrounding obstacles. Therefore, in this study, we compared and examined the installation standards of the obstacle limitation surface necessary for UAM to take off and land safely at the Vertiport. First, we analyzed the helicopter obstacle limitation surfaces in Japan and overseas, and the UAM Vertiport installation standards and obstacle limitation surface application standards recently announced at the FAA and EASA. It identified differences and similarities between heliport and Vertiport, and considered improvements to domestic helicopter obstacle limitation surfaces and criteria that could meet FAA and EASA standards.

The Actual Condition investigation of Residental Environment of Urban Life-Type Housing Regarding Crime Prevention Through Environmental Design -Focused on Five Single Households in studio-type housings in Gwanak-gu, Seoul Urban Life-Type Housing- (도시형생활주택의 범죄예방환경설계 측면에서 본 주거환경 실태조사에 관한 연구 - 서울시 관악구 원룸형 주택 1인가구 5개를 중심으로-)

  • Jung, Yoon-Hye;Lee, You-Mi;Lee, Youn-Jae
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.39-50
    • /
    • 2016
  • Purpose: The purpose of this study is to be performed with studio-type housings among urban life-type housings to investigate the physical characteristic and crime-related factors of studios from the viewpoint of the basic principles of crime prevention through environmental design (CPTED). Method: Eight CPTED guidelines available in Korea were reviewed to select 20 planing factors for actual condition investigation. Five single households in studio-type housings in Gwanak-gu, Seoul, were chosen according to the subject screening criteria to perform the actual condition investigation. Results: First, a lighting plan around a building for natural surveillance should consider the building location, relation with the front road, and surrounding facilities. In a building of a piloti structure, the parking lot and the building gate should be arranged in a manner that enables natural surveillance. Second, the shape of the corridors in studio-type housings should be considered to plan the installation of a lighting at the door of each household, the installation of a viewer window at the door of each household, and the arrangement of the elevator. Third, to support access control, an access control system having the function of video and voice communication is recommended to be installed at the building gate. Criteria for the type of security windows and the floors on which security windows should be installed, and the regulations about the CCTV installation inside and outside the building should be prepared. Fourth, to enhance territoriality in parking lots, ground patterns, parking lot gate, and signs may be installed. Fifth, in view of effective utilization and maintenance, lighting facilities should be installed to increase the usability of ground parking lots, and relevant installation criteria should be prepared regarding the type, number, and brightness of the lightings.

Appliance of Slab tracks on the Prestressed Concrete Bridges (슬래브궤도의 콘크리트교량 적용성 검토)

  • Kim, Nam-Hoon;Lim, Young-Su;Shin, Yong-Joon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1037-1043
    • /
    • 2007
  • The railroad systems with the ballast tracks have been widely used for a long time. But recently, the use of the slab track is being increased gradually with a technical developments. So, this paper deals with the appliance of the slab tracks on the railroad bridges. Firstly, review the design criteria of the railroad bridges related to the slab tracks for the stability and serviceability, based on DIN and EURO code. Then, perform the analysis of the railroad prestressed concrete bridges, and check whether the results of the analysis satisfy the design criteria. Finally, find the construction condition of bridges that all the design criteria are satisfied. As a result, to maintain the stability and serviceability of the bridges, bridges must have some restrictions, including a time of installation of the slab tracks. So, the construction schedule for the erection of the bridges will be carefully considered in case of the concrete railroad bridges with the slab tracks.

  • PDF

The Establishment of Evaluation Criteria for CD-ROM Encyclopedias (CD-ROM 백과사전의 평가기준 설정)

  • Park, Joon-Shik;Moon, Jung-Soon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.1
    • /
    • pp.17-37
    • /
    • 2000
  • This study aims to provide a guide to the selection and purchase of a good CD-ROM encyclopedia by establishing evaluation criteria for CD-ROM encyclopedia. This study first divided evaluation criteria into the following rune categories: reviews available, print version, availability of trial disc, hardware requirements and ease of software installation, database contents, retrieval software, standalone/network version, standard/deluxe version, costs. Next, it suggested evaluation points and items in detail under each category.

  • PDF

Management Criteria of Underground Strage Tank for Prevention of Soil Contamination (토양오염방지를 위한 지하저장탱크의 관리 방안 연구)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.453-460
    • /
    • 1998
  • The purpose of this study was to analyze their status of underground storage tank(UST) facilities and level of soil contamination, and to establish its management criteria. DB program was developed to analyze the correlation between specific characteristic of UST and level of soil contamination. For a suitable management of UST, leakage monitoring and inspection method of UST was investigated. Inspection period was established based on the leakage rate. The most dominant factor for leakage seemed to be caused by the corrosion. Therefore, main factor, construction method and installation year of UST, and corrosion protection system were suggested for optimal protection of UST. Considering the present management status of UST in Korea, inspection and management criteria of UST should be accomplished in term of contamination protection of leakage, and flexible regulation act should be introduced for each specific site.

  • PDF

Analysis and Experimental Study of Strength Change according to Fixed Knot Method of Fiber Rope for High Altitude Work (고소 작업용 섬유로프의 고정 매듭법에 따른 강도 변화의 해석 및 실험적 연구)

  • Song, S.M.;Kim, M.S.;Shin, D.Y.;Lim, S.H.;Kwon, O.H.;Park, W.R.
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.1-8
    • /
    • 2022
  • Workplace accidents are common while working at elevations. Thus, various safety measures such as safety handrails and horizontal safety nets are implemented to prevent falls. The minimum safety measure is the lifeline installation. However, because its standards have not been clearly established, it is often misused, resulting in inappropriate knot methods that increase the chance of accidents while working at elevations. Therefore, clarifying the appropriate usage methods or criteria for the various lifelines is required in the field. This study proposed an appropriate installation method by experimentally and numerically evaluating the change in strength according to the fixed knot lifeline method. In addition, three knot methods were specified for each material. The results obtained are expected to contribute to lessening falls through the establishment of lifeline installation standards and the development of appropriate parts.