• Title/Summary/Keyword: Installation Point

Search Result 723, Processing Time 0.028 seconds

A Study on Effectiveness Analysis and Development of an Accident Prediction Model of Point-to-Point Speed Enforcement System (구간단속장비 설치 효과 분석 및 사고예측모형 개발)

  • Kim, Da Ye;Lee, Ho Won;Hong, Kyung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.144-152
    • /
    • 2019
  • According to the National Police Agency, point-to-point speed enforcement system is being installed and operated in 97 sections across the country. It is more effective than other enforcement systems in terms of stabilizing the traffic flow and inhibiting the kangaroo effect. But it is only 5.1% of the total enforcement systems. The National Police Agency is also aware that its operation ratio is very low and it is necessary to expand point-to-point speed enforcement system. Hence, this study aims to provide the expansion basis of the point-to-point speed enforcement operation through analysis of the quantitative effects and development the accident prediction model. Firstly, this study analyzed the effectiveness of point-to-point speed enforcement system. Naive before-after study and comparison group method(C-G Method) were used as methodologies of analyzing the effectiveness. The result of using the naive before-after study was significant. Total accidents, EPDOs and casualty crashes decreased by 42.15%, 70.64% and 45.30% respectively. And average speed and the ratio of exceeding speed limit decreased by 6.92% and 20.50%p respectively. Moreover, using the C-G method total accidents, EPDOs and casualty crashes decreased by 31.35%, 66.62% and 10.04% respectively. And average speed and the ratio of exceeding speed limit decreased by 3.49% and 56.65%p respectively. Secondly, this study developed a prediction model for the probability of casualty crash. It was dependant on factors of traffic volume, ratio of exceeding speed limit, ratio of heavy vehicle, ratio of curve section, and presence of point-to-point speed enforcement. Finally, this study selected the most danger sections to the major highway and evaluated proper installation sections to the recent installation section by applying the accident prediction model. The results of this study are expected to be useful in establishing the installation standards for the point-to-point speed enforcement system.

A study on the Prevention of Malfunction by Developing Mechanical Sensing device of Railway Point (철도 선로전환기 기계식 밀착검지기 개발을 통한 장애경감에 관한 연구)

  • Yu, Jae-Hyeon;Sin, Myeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.404-409
    • /
    • 2007
  • To change rail tracks from main track to another track, it needs some device that is called turnout point. If the point which is composed of accurate parts and complex sensors does not work, serious problems will be arisen. However, there serious problems by the failure of the point. In this paper, after analyzing the failures of the conventional points, a new point is presented. The proposed point is not affected by surge caused by lighting.

  • PDF

Measurement and Computing Method of the Average Illuminance in Residential Areas (공동주택의 조도측정 및 평균조도 산출방법)

  • Joo, Keun-Tak;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The Five Point Method of KS and Four Point Method of IES are generally used to measure and compute the average illuminance in residential areas. Such methods of measurement should be used exactly according to the characteristics of the space and activities. Therefore, this study evaluated computation methods of the average illuminance in terms of comparing the measured values with simulated ones. The Five Point Method of KS is very closed to evaluate task illuminancefor appreciating activities at the center while the Four Point Method of IES is very closed to a concept of the average illuminance over the space excluding the possible maximum and minimum illuminance values.

A Study on Optimal Current Control Method for Small BLDC Motor Drive (소형 BLDCM 드라이브의 최적 전류제어에 관한 연구)

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.108-115
    • /
    • 2015
  • This paper proposed a optimal current control method to improve efficiency of BLDC motors. The aim of the proposed method is to use the maximum torque operating method by increasing the effective voltage at the maximum torque point unlike existing SPM operating method. The proposed method is based on existing IPM maximum torque operating method grafting onto a square wave operating of SPM motors. As the method of increasing the effective output voltage from inverter using the maximum torque point, the proposed method is to improve efficiency of BLDC motors using the same amount of the existing current effectively. For this method, the maximum torque point is carried out by FEA and analysis of magnetic flux vector. In this paper, the prototype of general-purpose BLDC drive is manufactured and the performance characteristic and validity are verified.

Power Quality Monitoring System Using DWB on Distribution Automation System (DWB를 이용한 배전자동화 기반의 전기품질 모니터링 시스템 구축)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.86-93
    • /
    • 2011
  • The necessity of Power Quality(PQ) Management grow bigger because the disturbance strength in power system is increasing, on the other hand, the tolerance of electrical components is reducing with widely use of the IT and digital equipments. The domestic management standards on power quality are enacted based on the IEC standards in recent. Since the IEC standards defines the measurement and evaluation point on PQ as PCC(Point of Common Coupling) which is normally the point of penetration between customer and power company, the PQ monitoring system(PQMS) should be made to measure and manage the PQ of custom effectively. In this paper, therefore, the economical construction plan on PQMS using the wireless communication channel in distribution automation system is suggested, and the usefulness of the PQMS are shown by analyzing the PQM data with IEC standards.

Ground Response Analysis of the Cmpressor Station for Installation of Seismic Instrument (정압관리소의 지전계측기 설치를 위한 지반특성 분석)

  • Kwon, Ki-Jun;Kim, Yong-Gil
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.1
    • /
    • pp.79-86
    • /
    • 2002
  • In the case of earthquake, it is necessary to install earthquake instruments and to measure the ground motions for stable gas supply and restoration in case of supply suspension. Because each point in the site of the gas facilities has different characteristics of ground motion, it is recommended to measure at the point where the ground motion is representative. In this paper, ground motion analysis and noise pattern analysis are carried out to select suitable point for the installation of earthquake instruments and to set of dynamic range of sensors.

A Study on Composition of A Novel Single Phase 3 Level Inverter Circuit (새로운 단상 3전위 인버터회로의 구성에 관한 연구)

  • 이종수;백종현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.5
    • /
    • pp.51-56
    • /
    • 1995
  • The transistors of single phase 3 level PWM Inverter compose output power transistors and neutral point clamping transistors, which are NPN transistors. Waveforms of driving signals for this are PWM waves for power transistors and period operating waves for neutral point clamping transistors, which signals made W-type modulation from rectangular and sine wave. The output power transistors operate at ON-time complementary and neutral point clamping transistors operate at OFF-time complementary respectively. Therefore, each transistors operate in half period at parallel. Characteristics of this inverter circuit is parallel switching method about series switching method of general inverter. As modulation of 3 level drive signals made from full-wave rectifier of sine wave and rectangular wave, which are level wave about 3 level of complementary transistor inverter. So, this circuit composed complementary operation inverter of NPN transistors only compare with PNP-NPN complementary inverter, which have high power 3 level inverter of complementary operation.

  • PDF

Effect of Phase Error on the Lateral Resolution of Reconstruction Image in Incoherent Triangular Holography (인코히어런트 삼각 홀로그래피에서 위상오차가 횡축방향의 해상도에 미치는 영향에 관한 연구)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.1-6
    • /
    • 2013
  • It is introduced the phase error sources of a incoherent hologram in incoherent triangular holography and derived the reconstruction image of point-source including the phase error in the lateral direction. From the reconstruction image of point-source, we analyzed the effect of phase error on the lateral resolution. When the phase retardation errors and azimuth angle error of a wave plate and a polarizer range from 0 to $2{\pi}/15$, the normalized intensities of reconstructed images are down by about 0.1% and 2.3%, respectively.

Calculation of Breakeven Point for LNG-Heavy Oil Transfer of D Thermal Power Plant Considering $CO_2$ Emission Cost ($CO_2$ 배출비용을 감안한 D 발전소의 LNG-중유 연료교제 손익분기점 계산)

  • Jeong, Yeong-Ho;Lee, Sang-Joong;Lee, Gene-Kyu;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.65-67
    • /
    • 2008
  • Kyoto Protocol against global warming came into effect in Feb 2005. This paper presents a calculation $CO_2$ emission of D power plant for combusting LNG and heavy oil using the a, b, c coefficients obtained by the performance test. The authors also calculate the breakeven point of the fuel transfer from LNG to Oil considering recent $CO_2$ emission cost.

  • PDF

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF