• Title/Summary/Keyword: Installation Effect

Search Result 1,466, Processing Time 0.029 seconds

A Applicability Study on Single Grouted Column Method (C-RJP Grouting) for Buoyancy-Resistant Permanent Anchor in Highly Permeable Volcanic Clastic Zones (투수성이 높은 화산쇄설층에서 부력앵커 시공을 위한 단일공 차수공법 (C-RJP Grouting)의 적용성에 관한 연구)

  • Jung, Yonggun;Chae, Youngsu;Park, Byunghee;Kim, Jeongryeol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.5-12
    • /
    • 2015
  • In this study, buoyancy-resistance permanent anchor was considered to prevent uplift pressure of a building structure. However, this test was failed to put anchor body in the boring hole because of the rapid outflow of ground water and coefficient of permeability. In addition, the hole where the anchor body was forcefully inserted constantly flew the sea water and cement. And it was found that anchor was not settled in the ground. In order to solve this problem, jet grouting method was applied to block the ground water and the single grouted column method was chosen to install the buoyancy-resistance permanent anchor. In this paper, the single grouted column method was applied with the general jet grouting methods and grout material was fixed by 3-field tests. These tests confirmed the effect of permeability and ground improvement with field permeability test by core sampling, Standard Penetration Test (SPT) and unconfined compression test. Confirming the stability of the buoyancy-resistance permanent anchor with installation and tension test, application of the single grouted column method in the volcanic clastic zones was verified.

Development of Improvement Effect Prediction System of C.G.S Method based on Artificial Neural Network (인공신경망을 기반으로 한 C.G.S 공법의 개량효과 예측시스템 개발)

  • Kim, Jeonghoon;Hong, Jongouk;Byun, Yoseph;Jung, Euiyoup;Seo, Seokhyun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.9
    • /
    • pp.31-37
    • /
    • 2013
  • In this study installation diameter, interval, area replacement ratio and ground hardness of applicable ground in C.G.S method should be mastered through surrounding ground by conducting modeling. Optimum artificial neural network was selected through the study of the parameter of artificial neural network and prediction model was developed by the relationship with numerical analysis and artificial neural network. As this result, C.G.S pile settlement and ground settlement were found to be equal in terms of diameter, interval, area replacement ratio and ground hardness, presented in a single curve, which means that the behavior pattern of applied ground in C.G.S method was presented as some form, and based on such a result, learning the artificial neural network for 3D behavior was found to be possible. As the study results of artificial neural network internal factor, when using the number of neural in hidden layer 10, momentum constant 0.2 and learning rate 0.2, relationship between input and output was expressed properly. As a result of evaluating the ground behavior of C.G.S method which was applied to using such optimum structure of artificial neural network model, is that determination coefficient in case of C.G.S pile settlement was 0.8737, in case of ground settlement was 0.7339 and in case of ground heaving was 0.7212, sufficient reliability was known.

Experimental Behavior Characteristics of 2×2 Group Pile under Lateral Loads (수평하중을 받는 2×2 무리말뚝의 실험적 거동 특성)

  • Kwon, Oh-Kyun;Park, Jong-Un
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.5-16
    • /
    • 2018
  • In this study, the large scale laboratory model tests were executed to investigate the lateral resistance characteristics of $2{\times}2$ group pile under lateral loads according to the array method and installation angle of piles. The effect on the behavior of $2{\times}2$ group pile was also investigated through model tests varying the pile diameter and length, distance to pile top from the ground surface, center-to-center (CTC) length and surcharge etc. From these test results, it was found that the lateral resistance of $2{\times}2$ group pile of which piles were constructed slantly in both directions was greater than that of group pile of which piles were constructed vertically. And as a result of parameter tests on the lateral resistance of $2{\times}2$ group pile, it was found that the most important parameter was the pile length. As the embedment depth ratio (L/D) increased to 36.5 from 26.5, the lateral resistance increased 3~4 times or more. But the center-to-center (CTC) length, distance to pile top from the ground surface and surcharge did not affect much on the lateral resistance of group pile.

A Quantitative Risk Analysis of Related to Tower Crane Using the FMEA (타워크레인의 정량적 위험성 평가가법에 관한 연구(FMEA 기법 위주))

  • Shim, Kyu-Hyung;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.34-39
    • /
    • 2010
  • The purpose of this study is to suggest objective evaluation model as a plan to utilize as opportunity in establishing judgment standard of mutual inspection criteria and to upgrade inspection ability by reviewing and analyzing level of danger and importance in advance based on inspection results of inspection institutions regarding tower cranes used in construction fields. Tower crane is a mechanical device transporting construction supplies and heavy materials to places over 20~150M high from the ground for the period ranging from a short time of 2~3 months to two years after being installed in construction sites in vicinity of buildings or structures and is an important facility indispensable for construction sites. However, since use period after installation is short and professional technical ability of technicians working on-site about of tower crane is poor, systematic and quantitative safety management is not carried out As a part of researches on procedure of RBI(Risk Based Inspection) possible to apply to Knowledge Based System based on knowledge and experiences of experts as well as to tower cranes for solving these problems, quantitative RPN(Risk Priority Number) was applied to RPN utilizing technique of FMEA(Failure Mode and Effect Analyses). When general RBI 80/20 Rule was applied parts with high level of risks were found out as wire rope, hoist up/down safety device, reduction gear, and etc. However, since there are still many insufficient parts as risk analyses of tower crane were not established, it is necessary for experts with sufficient experiences and knowledge to supplement active RBI techniques and continuous researches on tower cranes by sharing and setting up data base of important information with this study as a starting point.

Factors Influencing Field Monitoring of the Oriental Fruit Moth, Grapholita molesta, with Sex Pheromone (성페로몬을 이용한 복숭아순나방(Grapholita molesta) 모니터링에 영향을 주는 요인)

  • Kim, Yong-Gyun;Jung, Sung-Chae;Bae, Sung-Woo;Kwon, Bo-Won;Yoon, Hyang-Mi;Hong, Yong-Pyo
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.349-356
    • /
    • 2007
  • Three active components (Z8-12:Ac, E8-12:Ac, and Z8-12:OH) are known in sex pheromone of the oriental fruit moth, Grapholita molesta, and have been commercially available to apply for population monitoring and mating disruption. However, there have been variation among commercial products in pheromone composition and amount impregnated in each pheromone releaser. This study was performed to optimize factors influencing on pheromone monitoring of G. molesta by analyzing pheromone composition/amount, effective period of releaser, and trap type/placement in apple trees. High purity of Z8-12:Ac component was effective to attract males, in which 96% or more of cis acetate isomer component appeared to be optimal composition. Pheromone amounts ($0.01-1\;{\mu}g$) impregnated in each rubber dispenser did not give significant effect on monitoring during 90 days from June to August. "Delta" trap was much more efficient than "cone" trap to collect males. Trap installation was another factor, in which placing traps at canopy level was much efficient than at trunk or ground levels. Pheromone trap monitoring with these optimal factors indicated three to four adult peaks from June to September in addition to high overwintering population from April to May in pesticide-applied orchards in Andong, Korea.

Set up and Running Status of School Gardening at Elementary Schools - Focus on Jeollabuk-do (초등학교 학교 텃밭의 조성현황과 운영실태 분석 - 전북지역을 중심으로)

  • Jang, Yoonah;Jeong, Sun Jin;Han, Kyeong Suk;Gim, Gyung Mee;Choi, I Jin;Heo, Joonyung
    • The Korean Journal of Community Living Science
    • /
    • v.28 no.4
    • /
    • pp.613-623
    • /
    • 2017
  • This study was conducted to investigate the set up and running status of school gardening at elementary schools in Jeollabuk-do. Among 416 elementary schools in Jeollabuk-do, 164 schools (39.4%) had school gardens. Ninety-seven schools in cities and 67 in counties had school gardens. The total area and school garden size at schools in Jeollabuk-do were $45,490m^2$ and $277m^2$ per school, respectively, as well as $1.6m^2$ per students. School gardens varied in type, and percentages of outdoor and off-campus gardens were 67.2% and 17.2%, respectively. There were differences in the set up, type of garden, annual operating budget, and participants in school garden programs according to the location (city or county) of the school The installation and automation of facilities in the garden (such as greenhouse, tool shed, resource recycling facility, etc.) were poor. Most schools grew various kinds of plants, including vegetables, crops, ornamentals, and fruits. Teachers most often operated school gardens and taught students. Teachers had difficulty managing school gardens due to absence of knowledge about sustaining gardens. Most respondents reported the need for a school garden training program. Sixty-one percent of schools reported that the garden was used for academic instruction, especially during class. The majority of respondents agreed that school gardens have a positive effect and wanted to increase classes related to school gardens. Accordingly, in order to sustain school gardens and maximize their effects, systematic and customized support is needed that considers the characteristics and circumstances of the school. The facilities and features of the garden should be improved, and the school garden training program for teachers should attempt to reduce the effort required to manage the garden and increase utilization efficiency. In addition, participation of garden coordinators, parents, and community volunteers in managing gardens and implementing garden lessons is required.

A study on the Analysis Method and Pollution Measure of existed VOCs during the Bulk Liquid Cargo Operation at Vessels (산적 액체 화물 작업중 배출되는 VOCs 분석방법 및 오염 측정 연구)

  • Cheong, Kwang-Hyun;Lee, In-Ho
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.21-26
    • /
    • 2007
  • The Protocol adopted in Sep. 1997 included the new Annex VI of MARPOL 73/78, which entered into force on 19 May 2005. Revision for the accept MARPOL Annex VI with make public on 29 Dec. 2005 and enforce on 29 Jun. 2006. For all that not installation at oil terminal or if installed do not used. The purpose of this study is to research and evaluate the methods of sampling and analysis, and the pollution measure of existed VOCs during the bulk liquid cargo operation at vessels. As the sampling instrument of VOCs, Tedlar bag has the effect of decrease in concentration by the chemical reaction and absorption, and the method using the solvent extraction has error cause because of the extraction, the absorption tube has error by the breakthrough. But canister is the best sampling instrument because of having no sampling mistake. The study on VOCs emission is not sufficient for the research on the pollution cause and the analysis data on the HAP during the bulk liquid cargo operation at vessels. Hence, monitoring on the management hazardous VOCs need to be continued during the cargo operation at vessels and VOCs management field must be study for the make progress at a good pace for reason of crew's health.

  • PDF

The Effect of Decentralized Rainwater Tank System on the Reduction of Peak Runoff - A Case Study at M Village - (빗물저류조의 분산배치에 따른 첨두유출 저감효과 분석 - M 마을 사례 -)

  • Han, Moo-Young;Kum, So-Yoon;Mun, Jung-Soo;Kwak, Dong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • Recently climate change and increase of surface runoff caused the urban flooding. Traditional way of dealing with urban flooding has been to increase the sewer capacity or construction of pumping stations, however, it is practically almost impossible because of time, money and traffic problems. Multipurpose DRMS (Decentralized Rainwater Management System) is a new paradigm proposed and recommended by NEMA (National Emergency Management Agency) for both flood control and water conservation. Suwon City has already enacted the ordinance on sound water cycle management by DRMS. In this study, a flood prone area in Suwon is selected and analysis of DRMS has been made using XP-SWMM for different scenarios of RT installation with same total rainwater tank volume and location. Installing one rainwater tank of 3,000$m^3$ can reduce the peak flow rate by 15.5%. Installing six rainwater tanks of 500$m^3$ volume in the area can reduce the peak flow rate by 28%. Three tanks which is concentrated in the middle region can reduce peak rate more than evenly distributed tanks. The method and results found from this study can be used for the design and performance prediction of DRMS at a flood prone area by supplementing the existing sewer system without increase of the sewer capacity.

Separation of Valuable Metal from Waste Photovoltaic Ribbon through Extraction and Precipitation

  • Chen, Wei-Sheng;Chen, Yen-Jung;Yueh, Kai-Chieh
    • Resources Recycling
    • /
    • v.29 no.2
    • /
    • pp.69-77
    • /
    • 2020
  • With rapid increasing production and installation, recycling of photovoltaic modules has become the main issue. According to the research, the accumulation of waste modules will reach to 8600 tons in 2030. Moreover, Crystalline-silicon (c-Si) Photovoltaic modules account for more than 90% of the waste. C-Si PV modules contain 1.3% of weight of photovoltaic ribbon inside which contains the most of lead, tin and copper in the PV modules, which would cause environmental and humility problem. This study provided a valuable metal separation process for PV ribbons. Ribbons content 82.1% of Cu, 8.9% of Sn, 5.2% of Pb, and 3.1% of Ag. All of them were leached by 3M of hydrochloric acid in the optimal condition. Ag was halogenated to AgCl and precipitated. Cu ion was extracted and separated from Pb and Sn by Lix984N then stripped by 3M H2SO4. The effect of the optimal parameters of extraction was also studied in this essay. The maximum extraction efficiency of Cu ion was 99.64%. The separation condition of Pb and Sn were obtained by adjusting the pH value to 4 thought ammonia to precipitate and separate Pb and Sn. The recovery of Pb and Sn can reach 99%.

Stability Evaluation of Rear-Parapet Caisson Breakwaters under Regular Waves by Numerical Simulation (수치해석을 통한 규칙파를 받는 후부 패러핏 케이슨 방파제의 안정성 평가)

  • Lee, Byeong Wook;Park, Woo-Sun;Ahn, Sukjin
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.2
    • /
    • pp.95-105
    • /
    • 2020
  • In this study, using the CADMAS-SURF model, the characteristics of the wave pressures and the wave forces were analyzed according to the installation position of the parapet on top of the caisson, and the stability evaluation was carried out using estimated wave forces for the design wave condition. Numerical results show that adopting the rear-parapet reduces the front maximum wave pressures and wave forces, and the maximum wave pressure acting on the rear-parapet increases slightly compared to the front parapet, but the wave force acting on the rear-parapet has little effect on the stability of the breakwater due to the phase difference with the wave force acting on the front of the breakwater. In addition, impulsive wave pressures did not occur, as Yamamoto et al. (2013) pointed out the problem of the rear-parapet breakwater. As a result of the stability against sliding and overturning, it was estimated that the target safety factor of 1.2 could be secured by the self-weight of 13% less than the case of the front parapet. At this time, the maximum ground pressure was also reduced by 30%, and the applicability of the rear-parapet structure to the actual site was evaluated as high.