• 제목/요약/키워드: Installation Effect

검색결과 1,466건 처리시간 0.025초

Analytical Research of Topside Installation in Mating phase with Crane Vessel

  • Lee, Jong-Hyun
    • 한국해양공학회지
    • /
    • 제25권4호
    • /
    • pp.1-6
    • /
    • 2011
  • The installation of a topside structure can be categorized into the following stages: start, pre-lifting, lifting, lifted, rotating, positioning, lowering, mating, and end of installation. The transfer of the module onto the floating spar hull occurs in the last three stages, from lowering to the end. The coupled multi-body motions are calculated in both calm water and in irregular waves with a significant wave height (1.52m). The effects of the hydrodynamic interactions between the heavy lifting vessel and the spar hull during the lowering and mating stages are considered. The internal forces caused by the load transfer and ballasting are derived for the mating phases. The results of the internal forces for the calm water condition are compared with those in the irregular sea condition. Although the effect of the pitch motion on the relative vertical motion between the deck of the floating structure and the topside module is significant in the mating phases, the internal force induced pitch motion is too small to have this influence. However, the effect of the internal force on the wave-induced heave responses in the mating phases is noticeable in the irregular sea condition because transfer mass-induced draught changes for the floating structure are observed to have higher amplitudes than the external force induced responses. The impacts of the module on the spar hull in the mating phase are investigated.

막장볼트가 수평으로부터 벗어나는 경우 추가해 주어야 하는 본수에 대한 실내실험 및 수치해석 (A Laboratory Test and Numerical Analysis to Determine the Number of Additional Installation of Face Bolts due to the Deviated Bolts from the Horizontal Direction)

  • 서경원;이성원;김창용
    • 한국터널지하공간학회 논문집
    • /
    • 제8권4호
    • /
    • pp.345-354
    • /
    • 2006
  • 막장볼트는 시공중 지반조건 및 천공기계의 기계적 원인에 의해 수평으로부터 벗어나게 타설되는 경우가 많다. 본 연구는 실내실험과 수치해석을 통하여 막장볼트가 수평으로부터 벗어나는 경우에 대한 보강효과의 변화를 검증하였다. 또한 이 결과를 바탕으로 추가해 주어야 하는 볼트의 개수에 대하여 고찰하였다. 본 연구로부터 막장 중앙부부터 타설하는 막장볼트는 가능한 한 수평으로 타설하는 것이 효과적이며 벗어나는 경우에는 볼트를 추가해 주어야 하는 것이 명확해 졌다. 본 연구의 조건하에서는3본/단면을 타설 할 경우 모든 볼트가 $R15^{\circ}$로 수평으로부터 벗어나면 1.5본/단면을 추가해 주어야 하는 것으로 나타났다.

지오그리드의 장기설계인장강도에 미치는 시공시 손상 및 크리프 변형 복합효과에 대한 실험적 평가 (Experimental Investigations of Combination Effects of Installation Damage and Creep Deformation on Long-Term Design Strength of Geogrids)

  • 조삼덕;이광우;오세용;이도희
    • 한국지반신소재학회논문집
    • /
    • 제4권4호
    • /
    • pp.23-37
    • /
    • 2005
  • 지오그리드의 장기설계 인장강도는 크리프 변형, 시공시 손상 및 환경적 요인(온도, 화학적 손상, 생물학적 손상)에 영향을 받는다. 특히, 크리프 변형 및 시공 시 손상이 가장 크게 영향을 미치는 요인으로서 반영된다. 보강토구조물에 대한 대부분의 현행 설계법에서는, 이들 영향요인을 각각 산정하여 이를 장기인장강도 산정에 반영하고 있다. 즉, 이러한 방법에서는 지오그리드의 시공 중 손상과 크리프 변형의 복합효과가 장기 설계인장강도 산정에 어떤 영향을 미치는 가에 대한 검토가 되어 있지 않다. 본 연구에서는 지오그리드의 시공 중 손상과 크리프 변형의 복합효과가 지오그리드의 장기인장강도 산정에 영향을 미치는 영향을 평가하기 위한 일련의 실험적 연구를 수행하였다. 다양한 지오그리드를 대상으로 성토흙 종류에 따른 현장 내시공성시험을 수행하였고, 지오그리드 원시료와 시공중 손상을 입은 시료를 대상으로한 크리프시험을 수행하였다. 연구결과 두 영향인자의 복합효과를 고려하여 산정한 지오그리드의 인장강도 감소계수가 현행 설계법에 의해 산정된 감소계수보다 작은 것으로 나타났다.

  • PDF

NATM 터널에서 경사 록볼트의 보강효과에 대한 3차원 해석 (3D Numerical Study on the Reinforcing Effect of Inclined System Bolting in NATM Tunnel)

  • 허준;김병일;이재덕;김영근
    • 한국지반공학회논문집
    • /
    • 제33권3호
    • /
    • pp.29-36
    • /
    • 2017
  • NATM 공법에서 터널을 확대하거나 피난갱과 같이 좁은 단면에 록볼트를 설치하는 경우에는 록볼트를 경사지게 설치하거나 또는 짧은 볼트를 연결하여 시공할 수밖에 없다. 국내외에서 실시된 경사 록볼트에 대한 연구는 아직 미흡한 실정이며 실제 현장에 적용하기 위해서는 경사 록볼트의 거동특성에 대한 연구가 필요하다고 사료된다. 본 연구에서는 3차원 유한요소해석을 사용하여 경사 록볼트 시공 시 록볼트의 설치각도와 설치길이에 따른 최대 중립점 발생위치의 변화를 확인하고 이에 따른 록볼트에 의한 원지반 아치형성영역의 두께 변화를 비교 분석하여 지반보강효과에 대해 확인하였다. 해석결과 표준지보패턴(설치길이 4m)에선 설치각도가 감소할수록 터널 주변지반의 변형범위는 증가하여 지반보강효과가 감소하는 것을 알 수 있었다. 또한, 설치길이가 증가함에 따라 설치각도에 의한 영향을 적게 받은 것으로 나타났으며 설치각도 $45^{\circ}$ 이하에서는 설치길이의 영향을 받지 않는 것으로 나타났다. 이러한 결과로부터 경사록볼트의 설치각도는 $45^{\circ}$이상으로 하여 아칭영역을 확보하도록 하여야 하며, 설치각도 $75^{\circ}$이상인 경우 직각으로 설치하는 경우와의 보강효과의 차이가 크지 않음을 확인하였다. 또한 추가적인 상세 검토를 통하여 NATM 터널에서의 경사록볼트 설계지침을 제시하고자 하였다.

중국 사막지역의 방풍책 높이와 공극률에 따른 방풍효과 및 설치비용 비교분석 (Comparative Analysis of Windbreak Effect and Installation Cost of Sand Barrier with Different Height and Porosity on Sand Land in China)

  • 박기형;정국동;방엄령;김찬범;오빈;포암봉;고엄뢰;정성철;문강민
    • 한국환경복원기술학회지
    • /
    • 제15권6호
    • /
    • pp.29-41
    • /
    • 2012
  • This study was conducted in Ningxia Hui autonomous region, located at southern part of Mu Us sand land in China. To investigate relationships between windbreak effect and installation cost of sand barriers, plastic net is utilized by using four kind of heights (0.2, 0.3, 0.4 and 0.5m) and four kind of porosities (20, 30, 50 and 70%). These heights and porosities are measured for estimating distances for effective windbreak. It is shown that porosity and the distance have a positive relationship at same heights and porosity on ground indicates a constant figure when height reaches a certain level, regardless of the porosity. This implies that there is a difference of level of windbreak with different porosities; however, distance of windbreak effect is same at the same height of sand barrier. As a result of comparison between porosity of sand barrier on the ground and installation cost in each sand barrier with various heights and porosities (16 combinations), 0.4m and 0.5m height sand barriers describe highest economical efficiency. Within two variables, we concluded that height has a higher impact on windbreak effect than porosity.

인하도선시스템 시설에서의 문제점과 대책 (Problems and Countermeasures in Installation of Down Conductor Systems)

  • 이복희;이동문;강성만;엄주홍;정동철;이승칠;안창환
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.38-45
    • /
    • 2002
  • 내본 논문에서는 뇌서지에 의해서 발생하는 컴퓨터를 비롯한 전자기기의 장해에 대한 보호대책을 제안하기 위해서내 국내의 뇌보호설비에 대한 규격과 지침에 대한 기술적인 문제점을 분석하였다. 인하도선의 설치방법에 따른 인하도선과 인입용 금속관을 통하여 흐르는 전류사이의 관계를 검토하였으며, 인하도선계에 미치는 표피효과의 영향을 평가하는 실험을 수행하였다. 그 결과 인하도선을 인입용 금속관에 전기적으로 접속한 때 인하도선과 금속관은 하나의 도체로 작용하며, 표피효과와 쵸킹효과 때문에 뇌격전류는 인하도선보다도 금속관을 통하여 훤씬 많은 전류가 흘렀다. 따라서 뇌격전류에 의한 인하도선의 전위상승으로 야기되는 정전유도와 측면방전 등의 악영향을 억제하기 위해서는 인하도선을 인입용 금속관과 건물의 철골 구조체에 전기적으로 접속하는 것이 매우 효과적이다.

동기릴럭턴스전동기의 전류센서리스 제어 성능 고찰 (Considerations on the Performance of Current Sensorless Control of a Synchronous Reluctance Motor)

  • 신명호
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.61-65
    • /
    • 2012
  • Some works about the current sensorless control of a synchronous reluctance motor have been presented. However, there is no analysis about the performance and the detuning effect of the current sensorless control. This paper presents the problems and the detuning effect of the current sensorless control of a synchronous reluctance motor by simulation results. In addition, torque limiter is proposed to limit the torque current within the torque limit.

저압용차단기 전원 개폐시 개인용 PC에 미치는 영향 분석 (Analysis of Effect on Personnel Computer in case of turning off Power supply of Circuit Breaker for Low Voltage)

  • 길형준;송길목;김영석;김종민
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.124-129
    • /
    • 2014
  • This paper describes the analysis of the effect on personnel computer in case of turning off power supply of main breaker in general electrical installation. In order to analyze the effect on personnel computer in case of turning off the power supply of main breaker, the switching impulse generator has been designed and fabricated which makes it possible to evaluate the effect on electrical product by switching impulse. The switching impulse tests were carried out for personnel computer according to applied voltage and number of switching impulse. As a consequence, switching impulse had not a significant influence on personnel computer in this study. The varistor of power input section functions as a protection of switching impulse as well as lightning impulse. The results will be used to related organization, and electrical product manufacturer, and residents.

전기설비용 PET의 절연파괴와 공간전하효과에 관한 연구 (A Study on the Effect of Space Charge and tole Dielectric Breakdown of PEF for Electric Installation)

  • 윤성도;박상현;정학수;서장수;박중순;국상훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.37-40
    • /
    • 1992
  • This paper examined the existance behavior of charged particles by measuring polarity inversion current Thermal Stimulate Current (TSC) and analysed appearance mechanism of polarity inversion current Peak and Also investigated relation between ionic space charge format ion and dielectric breakdown by measuring D.C breakdown impulse breakdown D.C - impulse superposition as a sample of FET. As a result. lie found that dielectric breakdown is likely to happen due to ionic space charge at the transient state when applied polarity inversion voltage and that charged partion of TSE Peak at the high temperature was the same as that of polarity inversion current. Also there was no effect on ionic space charge about the dielectric breakdown in stationary state when applied D.C voltage.

  • PDF

2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석 (Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems)

  • 정채균;김상국;이종범;정영호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.