• 제목/요약/키워드: Installation Effect

검색결과 1,466건 처리시간 0.032초

Experimental and numerical study on coupled motion responses of a floating crane vessel and a lifted subsea manifold in deep water

  • Nam, B.W.;Kim, N.W.;Hong, S.Y.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권5호
    • /
    • pp.552-567
    • /
    • 2017
  • The floating crane vessel in waves gives rise to the motion of the lifted object which is connected to the hoisting wire. The dynamic tension induced by the lifted object also affects the motion responses of the floating crane vessel in return. In this study, coupled motion responses of a floating crane vessel and a lifted subsea manifold during deep-water installation operations were investigated by both experiments and numerical calculations. A series of model tests for the deep-water lifting operation were performed at Ocean Engineering Basin of KRISO. For the model test, the vessel with a crane control system and a typical subsea manifold were examined. To validate the experimental results, a frequency-domain motion analysis method is applied. The coupled motion equations of the crane vessel and the lifted object are solved in the frequency domain with an additional linear stiffness matrix due to the hoisting wire. The hydrodynamic coefficients of the lifted object, which is a significant factor to affect the coupled dynamics, are estimated based on the perforation value of the structure and the CFD results. The discussions were made on three main points. First, the motion characteristics of the lifted object as well as the crane vessel were studied by comparing the calculation results. Second, the dynamic tension of the hoisting wire were evaluated under the various wave conditions. Final discussion was made on the effect of passive heave compensator on the motion and tension responses.

공동주택 건물의 상수도 절감량에 따른 CO2 배출량 저감효과에 관한 연구 (A Study on the CO2 Emission Reduction Effect relating to the Water Usage Reduction in Multi-family Residential Building)

  • 조수현;강혜진;이언구
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.126-133
    • /
    • 2011
  • The current world wide interest in environmental issues has moved from energy conservation to $CO_2$emission reduction. Recently, according to the increase in demand for water resources, insufficient potable water circumstance is supposed, unless there are corresponding in crease in water conservation and water recycling. This study has attempted to analyze $CO_2$emission reduction by water saving strategies like installation water saving devices, rain water harvesting and grey water system. To do this, this research investigates applicable water conservative strategies by literature review and calculated total water saving. The results show that (1) firstly, the water usage and $CO_2$ emission could be reduced up to 44%, (2) $CO_2$ emission reduction by water saving devices and rainwater harvesting system is about 47.7%, and (3) water usage and $CO_2$ emission reduction by grey water system is about 66%. In the future, this paper will be utilized for water management from the early design stage to maintenance stage of water glutton building.

스펜드럴부 적용 BIPV 모듈의 열 특성 분석 (Analysis on Thermal Performance of BIPV in Spandrel)

  • 김하련;김진희;강기환;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2011
  • Recently, the cases of BIPV(Building-integrated Photovoltaic) have been increased with interest in renewable energy application for buildings. PV System in building can perform a variety of roles as an energy supplier, exterior materials, aesthetic element and etc. To apply PV modules in buildings, various factors should be considered, such as the installation angle and orientation of PV module, shading, and temperature. The temperature of PV modules that are attached to building surfaces especially is one of the most important factors, as it affects both the electrical efficiency of a PV module and the energy load in a building. BIPV modules designed as finished material for spandrels are presented in this paper. The purpose of this study is to analysis on the thermal performance characteristics of BIPV modules. This study dealt with different types of BIPV modules depending on the backside material, such as clear glass and backsheet. The analysis of monitoring data shows that the PV module temperature was closely related to the solar radiation on the BIPV module surface, and the BIPV used at the backside also had an effect on the PV module temperature that in turn determines its thermal performance.

  • PDF

태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구 (A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region)

  • 김태곤;최태호;김경필;구자용
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

룸코너 시험을 이용한 배관용 보온재의 난연성능 분석 (Evaluation of the Reaction-to-fire Performance of Pipe Insulation Material using Small Room Test)

  • 임옥근;남동군;장효연
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.1-8
    • /
    • 2019
  • 천장이나 배관에 설치된 보온재의 연소로 인해 화재가 확산되는 사례가 발생함에 따라 수계소화설비의 배관보온재는 난연재료 성능 이상의 것을 사용하고 있다. 배관보온재의 일부분을 시편으로 가공하여 난연성능을 평가하고 있지만 설치환경을 고려한 실규모시험을 통한 평가는 이루어지지 않고 있다. 본 연구에서는 국내에서 널리 사용되고 있는 발포폴리에틸렌폼 및 고무발포보온재를 실규모 시험기준인 ISO 20632에 따라 시험하고 유럽의 난연성능 분류 기준과 비교하였다. 배관보온재 재료별로 상이한 난연성능을 보였으며, 특히 발포폴리에틸렌폼보온재의 경우 시공방법에 따라 화재성장율 및 열방출율이 달라졌다. 화재발생 시 배관보온재로 인한 연소확산을 지연시키기 위해서는 설치하는 대상공간의 특성을 고려한 난연성능 적용이 필요하며, 시공 시 사용하는 접착제와 테이프 등 부자재의 난연성 또한 고려해야 함을 확인할 수 있었다.

도시유역의 침투시설 설치위치와 종류에 따른 유출저감효과 분석 (Analysis of Runoff Reduction Effect of Infiltration Facility Installation Position and Kinds of Infiltration in Urban Basin)

  • 이재준;곽창재;설지수
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.54.2-54.2
    • /
    • 2010
  • 본 연구는 침투시설의 설치위치와 종류에 따른 유출저감효과를 WinSLAMM 모형을 이용하여 분석한 것이다. 본 연구의 대상유역은 Driveway 38%, Residential Area 8%, Parking Storage 8%, Sidewalk 8%, Playground 8%, 투수유역(Landscaped Area) 30%와 같이 토지이용별로 구획된 총면적 $0.25km^2$의 전형적으로 도시화된 가상유역으로 설정하였다. 침투시설 설치에서 중요한 요소 중 하나인 시설의 포화를 고려하기 위하여 10mm/hr~30mm/hr범위의 강우를 적용하였으며, 설치위치와 종류별 침투시설의 정량적인 유출저감효과를 비교하기 위하여 Residential Area, Parking Storage, Playground와 같은 유역내 불투수유역과 유출구에 해당하는 Outfall에 일정한 규모의 침투트렌치와 침투통을 설치하였다. 침투시설은 강우의 크기에 따라 시설의 포화가 진행되며 일정 규모 이상의 강우 발생시 침투기능을 상실하므로 강우의 크기에 맞는 포화시점을 찾아 적절한 규모로 설치해야하고, 경호우에서 유역내의 침투시설의 가용면적을 증가시키면 유출저감효과도 증가하였으나, 강우가 커질수록 상대적으로 가용면적이 큰 유출구와 차이가 없거나 오히려 더 낮은 유출저감효과가 나타나기도 하였다. 또한 설치위치에 침투시설을 비교한 결과, 경호우의 경우 동일한 유출저감효과가 나타났으나, 침투트렌치가 포화에 이루어지기 전까지는 유출저감효과가 더 높았으며, 유출구에서는 침투트렌치가 침투통보다 더 높은 유출저감효과가 나타났다. 침투시설의 병행설치시 경호우에서는 병행설치의 효과가 없었으나 강우강도가 증가할수록 효과가 뚜렷하게 나타났고, 유역내 침투시설의 병행설치시 가용면적을 증가시킬수록 유출저감효과도 증가하여 경호우 이상의 강우에서 병행설치를 고려되어야한다는 결론을 얻었다.

  • PDF

농기계의 등화장치가 운전자의 야간시인성에 미치는 영향 (Effect of Agricultural Machine Lighting systems on Drivers Night Visibility)

  • 최승현;이성렬;장택영;도명식
    • 한국ITS학회 논문지
    • /
    • 제16권4호
    • /
    • pp.25-35
    • /
    • 2017
  • 본 연구는 야간 시간대의 농기계 주행시 등화장치 장착여부에 따른 운전자의 야간시인성분석을 목표로 하였다. 야간시인성 분석을 위해 등화장치에 대한 휘도측정실험과 안구운동측정기기를 활용한 주시시간측정실험을 수행하였다. 휘도측정실험결과, 농기계와의 상대거리가 가까워지며 등화장치의 상태가 양호해질수록 휘도 값이 증가하는 것으로 나타났다. 또한, 주시시간측정실험에서는 주행속도에 상관없이 등화장치의 상태가 양호해질수록 농기계에 대한 총 주시시간이 증가하는 것으로 나타났다. 연구결과, 농기계에 등화장치를 장착할 경우 농기계에 대한 운전자의 야간 시인성이 향상되어 농기계사고의 예방에 큰 도움을 줄 수 있을 것으로 기대된다.

고전력 활선 XLPE 케이블의 열화를 측정하기 위한 판정기준의 적용 및 절연상태 판정 (Application of Judgement Criteria to Measure Deterioration and to Judge Insulation Resistance in High-Power Live XLPE Cables)

  • 엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제17권2호
    • /
    • pp.239-244
    • /
    • 2017
  • 전력 수요는 매년 증가추세에 있으며, 이에 따라 발전소에서 동작하는 모든 장비들과 대용량의 장거리 전력수송을 위한 장비들은 신뢰할 수 있는 수준에서 완전한 상태로 동작하여야 한다. 발전소에서 생산한 고전압 전력을 전달하기 위해 사용하는 케이블은 주로 6.6 kV XLPE 케이블(또는 CV케이블)이다. 제작 기술, 설치환경 및 사용조건에 다르겠지만, 케이블은 동작함과 동시에 열화과정이 진행된다. 접속재의 경우, 제조 결함이나 공사 결함이 있는 경우 대체로 동작 후 약 3 년 내에 고장을 일으키며, 그렇지 않는 경우 수명이 20-30 년을 지속하는 경우가 많다. 우리는 케이블의 열화 상태를 감시하기 위한 장비를 개발하여 충남 태안의 한국서부발전주식회사(Korea Western Power Co. Ltd.)에 설치하였다. 우리는 이 논문에서 케이블의 열화 판정의 기준을 설정하고, 기준에 따른 열화정도를 판정하고, 케이블의 대체여부를 결정함으로써 발전소에서 설치된 활선 케이블의 동작 상태를 감시한 결과와 케이블을 구성하고 있는 절연체와 방식층이 절연저항 특성에 미치는 영향 및 케이블의 동작에 미치는 영향을 연구한 결과를 제시한다.

도시가스 고압배관의 합리적인 위험감소조치 선정을 위한 비용-편익분석 (Cost-Benefit Analysis in order to Select the Reasonably Practical Risk Reduction Measures(RRMs) on High Pressure Urban Gas Pipelines)

  • 류영돈;김영섭;이수경
    • 한국가스학회지
    • /
    • 제15권2호
    • /
    • pp.40-46
    • /
    • 2011
  • 위험성 평가에서 비용-편익분석의 목적은 위험성 평가를 통해 도출된 부가적인 위험감소조치의 편익이 그 조치를 수행하는 데 든 비용보다 많음을 확인하고, 그 조치를 이행하는 것이 적절함을 보여주는 데 있다. 본 논문에서는 도시가스 고압배관의 위험성 평가에 따라 도출한 위험감소조치를 이행함에 있어 가장 효과적이고 합리적인 조치를 선정하기 위하여 비용-편익 분석을 실시하였다. 도출한 위험감소조치를 적용하여 위험성 평가를 다시 실시한 결과, 배관부식방지조치, MOV 설치 및 타공사 방지조치를 하도록 한 10번 조치가 위험감소효과가 75 %로 가장 컸으며, 비용-편익 분석 결과 합리적으로 실행가능한 것으로 판단되어 본 논문의 연구대상 배관의 위험감소조치로 선정하였다.

컴퓨터 시뮬레이션을 이용한 음의 사각지역 및 음상의 경제적 개선방안 연구 (A Study for economic improvement of sound image localization and dead zone using computer simulations)

  • 고은지;이현수;이경량;김성권
    • 한국전자통신학회논문지
    • /
    • 제6권5호
    • /
    • pp.703-708
    • /
    • 2011
  • 본 논문에서는 대형 교회를 제외한 대부분의 교회가 협소한 공간에 많은 청중을 수용하고자 발코니 층을 설치하여 음의 사각지역 및 음상 정위가 어긋난 지역이 발생하는 문제를 경제적 관점에서 컴퓨터 시뮬레이션을 이용하여 음의 사각지역 및 음상의 개선하는 해결방안을 제시한다. 본 연구에서는 특정교회에 대하여 컴퓨터 시뮬레이션 툴로 경제적으로 쉽게 구할 수 있는 Mapp online으로 사용하였으며, 서브 스피커의 추가 설치 및 메인 스피커 대비 서브 스피커의 -10 dB 이득조절로 명료도를 실측값과 비교한 결과 약 52% 상승하여 명료도가 "보통"에서 "아주 좋음" 단계로 개선됨을 확인할 수 있었다.