• Title/Summary/Keyword: Installation Effect

Search Result 1,466, Processing Time 0.029 seconds

Numerical Study of Impact for Particulate Matter Reduction Device According to Installation of Perforated Plate and Mixer on Marine Diesel Engine (선박용 디젤엔진의 미세먼지저감 장치에 다공판과 믹서의 장착이 미치는 영향에 대한 수치해석적 연구)

  • Yun, Byoungkyu;Cho, Sanghyun;Ryu, Younghyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.968-973
    • /
    • 2019
  • This study presents the characteristics of a pressure drop and uniformity index for a particulate matter reduction device with a perforated plate and mixer for marine diesel engines. The perforated plate and mixer equipped on the particulate matter reduction device induce an increase of exhaust gas reduction performance by increasing the uniformity index. Whereas, the perforated plate induces pressure drop increases in the particulate matter reduction device. Therefore to calculate the effect of the uniformity index and pressure drop of the perforated plates and mixer, this study combines several cases using five types of perforated plates and one type of mixer. Consequently, these results were analyzed to determine the optimized type and position of the perforated plate and mixer.

An Estimation of the Consequence Analysis for an Underground Installation of the LPG Storage Tanks (소형 LPG 저장탱크 매몰 설치에 대한 피해영향평가)

  • Song, Dong-Woo;Jun, Woon-Young;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.62-67
    • /
    • 2015
  • In this paper, the consequence analysis has been evaluated for the damage effects of the LPG storage tanks when they are installed on the ground or underground. They should be performed to identify measures to reduce risks for the LPG storage tanks which are more widely used. In order to conduct a damage effect evaluation of the LPG storage tanks installed underground, FDS was used to simulate the LPG storage tanks installed and housed within a facility. The maximum pressure of the storage facilities for the LPG storage tanks has been calculated from the FDS, and it's results are used as an input variable for Phast which is a commercial software for evaluating the damage effects. Getting results from the consequence analysis and computational simulations(diffusion range of LFL and UFL, jet fire or explosions) were quantitatively presented for the damage effects.

A Study on The Safety Management of City Gas Pipelines Attached on the Bridges (교량에 설치된 도시가스배관의 안전관리에 관한 연구)

  • Yun, Young-Man;Son, Sang-Geun;Choi, Do-Kyun;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • In this study, 398 city gas pipe systems installed on the bridges were surveyed and analyzed classified characteristics about the ages, length, and remote isolation devices installed or not. As a result of analysis, 43.0% pipes have been used more than 20 years and 89.4% do not have remote cut-off devices, so this study suggest safety management ways for the issues. Chosen 76 pipes were researched stress strain characteristics by CAESAR-II which is a specialized program for stress analysis. And, when a loop is installed on the bridge pipe, effect on code stress by the location and size of the loop was performed. This study can help to improve safety level by revising criteria of new installation, inspection and diagnostic.

Study on Fault Detection System used the Classified Rule-based of HVAC (분류형 규칙기반을 이용한 HVAC 시스템의 고장검출에 관한 연구)

  • Yoo, Seung-Sun;Youk, Sang-Jo;Cho, Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11B
    • /
    • pp.655-662
    • /
    • 2007
  • Monitoring systems used at present to operate HVAC(Heating, Ventilation and Air Conditioning) optimally do not have a function that enables to detect faults properly when there are faults of such as operating plants or performance falling, so they are unable to manage faults rapidly and operate optimally. In this paper, we have developed a classified rule-based fault detection system which can be inclusively used in HVAC system of a building by installation of sensor which is composed of HVAC system and required low costs compare to the model based fault detection system which can be used only in a special building or system. In order to experiment this algorithm, it was applied to HVAC system which is installed inside EC(Environment Chamber), verified its own practical effect, and confirmed its own applicability to the related field in the future.

A Difference Study on the Lighting Simulation of the Illuminance Values from Daylight for the Glass Greenhouse (자연광 투과에 따른 유리온실 조도분석에 관한 조명시뮬레이션 비교)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.350-354
    • /
    • 2017
  • In this study, the DIAlux program was simulated for the optimal conditions of daylight and artificial light sources(LED) in a glass greenhouse. From the results of the daylight simulation, the optimal design conditions for the glass greenhouse were established, which had a $90^{\circ}$ installation angle and a higher transmittance of glass. In the case of growing lettuce in a glass greenhouse, it was compared with artificial light sources, the artificial light source (LED) was used to produce a power consumption effect of 41%. These results suggest that lettuce be grown in an energy saving glass greenhouse.

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

Effect of Stability of Reinforced Wall within Drain Layers in the Rainfall (강우시 보강토 내부 배수가 보강토 옹벽의 안정성에 미치는 영향)

  • Sin, Chun-won;Yoo, Chung-Sik
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.165-174
    • /
    • 2017
  • There are natural disasters caused by abnormal climate in the world. In particular, there are frequent disasters such as floods and landslides caused by rainfall in summer. Rainfall will have a major impact on the stability of a retaining wall. If drainage during rainfall activities within the retaining wall is not made properly, permeated water brings a significant increase in pore pressure inside of the backfill soil and reduces the shear strength of the soil. Therefore, research how to install the drainage layers to reduce the infiltrated water inside of the backfill soil is very necessary. In this study, we performed a numerical modeling to find the optimum installation conditions of the location and number of drainage layer related to stability of the reinforced retaining wall during rainfall installed geosynthetics.

A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process (파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구)

  • Kim, Seung Hwan;Kim, Se Woon;Lee, Dong Woo;Cho, Jin Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.3
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.

Improved design for mooring line with lumped weight at seabed (중량체 적용을 통한 계류선의 설계개선 방안 연구)

  • Song, JaeHa;Shin, SeungHo;Jung, DongHo;Kim, HyeonJu
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.22-26
    • /
    • 2013
  • The purpose of this study was to improve the design of a mooring line by attaching a lumped mass to it on the seabed. A numerical analysis of the redesigned mooring system is performed to analyze the effect of the weight of the attached lumped mass using the commercial software Orcaflex. The ultimate tension of the mooring system with the lumped mass is compared with that of a bare mooring line in the original design. An appropriately designed weight for the lumped mass is found to induce a critical lifted point in the mooring line by floater motion in the ultimate condition to move toward the floater position from the anchor point, while maintaining a similar safety factor for the mooring line. On the other hand, it is shown that excess weight for the lumped mass induces snapping in a mooring line, resulting in low safety factor for the mooring system. The distance between lumped weights is shown to be a minor parameter affecting the safety of a mooring line, although a shorter line has an advantage from an economic point of view. Using the optimal weight for the lumped mass attached to the mooring line on a seabed reduces the mooring line length and installation area occupied by a mooring system under real sea conditions.

An Experimental Study for the Improvement of Ventilation Conditions and Effectiveness in the Manufacturing Industry by Increasing the Mixing Factor (K-Factor) (혼합계수(K-Factor) 증가에 따른 사업장의 환기 조건 및 효율 개선에 관한 연구)

  • Lee, Yun-ho;Lee, Seokwon;Lee, Kyoungho;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.343-350
    • /
    • 2019
  • Objectives: This study aims to identify whether ventilation conditions and their effectiveness can be significantly improved in an experimental chamber by increasing the mixing factor (K-Factor). Methods: In a chamber with a volume of $1m^3$, air velocity was measured at six different points with four roof fans in the upper part of the chamber being operated in order. The impact of the ventilation conditions was analyzed when the flow rates were increasing and the first inlet of the chamber was either open or closed. Smoke patterns were also observed at four corner points where ventilation was limited. Kruskal Wallis and Mann-Whitney tests were performed to compare air velocities measured in the chamber. Results: The air velocities measured at only the third point increased significantly from $0.03{\pm}0.03m/s$ (door open) and $0.05{\pm}0.06m/s$ (door closed) with two fans, $0.08{\pm}0.08m/s$ with three fans, and $0.09{\pm}0.09m/s$ with four fans operating (p<0.05). However, air velocities at the four corner points did not significantly increase. Smoke patters also showed that the open inlet of the chamber had no effect on improvement of ventilation conditions and effectiveness. Conclusions: In this study, the air velocities at six points in the chamber did not significantly increase despite the increase in the mixing factor and flow rates of ventilation in the controlled environment. Therefore, the inflow of outdoor air throughout an open inlet and installation of a forced ventilation system can potentially increase the indoor air velocity and improve ventilation condition without an increase in the mixing factor.