• Title/Summary/Keyword: Installation Cost

Search Result 1,176, Processing Time 0.026 seconds

Modeling of Hybrid Superconducting Fault Current Limiter(HSFCL) using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 하이브리드 초전도 전류제한기 모델링)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.46-48
    • /
    • 2008
  • The increase of fault current due to large demand has caused the capacity of power machines in power grid to increase. To protect the power system effectively from the large fault current, several superconducting fault current limiters have been proposed. however, in order to apply superconducting fault current limiters into power system, there are many problems such as cost, recovery, AC loss, and cryogenic. In order to solve these problems, hybrid superconducting fault current limiter(HSFCL) was proposed. In this paper, we modeled hybrid superconducting fault current limiter using PSCAD/EMTDC and analyed fault current limiting characteristic and total resistance of hybrid superconducting fault current limiter.

  • PDF

Application of the Robot for Curtain Wall Installation in a High Building (고층 빌딩 커튼월 시공 작업에서의 로봇 활용에 관한 연구)

  • Lee, Soung-Yel;Ko, Bong-Soo;Lee, Kye-Young;Lee, Sang-Heon;Ohk, Young-Mu;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1488-1493
    • /
    • 2003
  • Recently, higher and bigger building is trend of the construction. Accordingly the building material is getting bigger and construction equipments are developed. But operation is still depends on human resource. Therefore there have several problems that are safety, laborious operation, and shortage of worker. In the various construction sites, the automation in construction is introduced to solve these problems. This paper proposed the automation system in construction that installs curtain wall in a high building. The system is expected effects that are reduction of a construction period, retrenchment of the cost and assurance of safety.

  • PDF

First Installation of High Stress EHV XLPE Cable in korea (초고압 고내력 케이블 국내 최초 현장 적용)

  • Oh, J.O.;Cho, S.H.;Lee, S.K.;Kim, H.J.;Oh, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

Hydraulic Constant Frequency Generation System Driven by Main Engine for Small Fishing Boat - Hydraulic Pump Control Type - (소형 어선용 주기구동 유압식 고주파수 발전장치에 관한 연구 ( 1 ) - 유압펌프 제어방식 -)

  • Lee, Il-Yeong;Park, Sang-Gil;Jeong, Yong-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.30-35
    • /
    • 1988
  • An electrical power generation system driven by main engine shaft, briefly SG system for middle or small size fishing boat is studied experimently. In the SG system, power transmission is performed by a variable displacement hydraulic pump driven by the main engine and a constant displacement hydraulic motor. It was verified that the SG system enabled the generation of electrical power with constant frequency regardless main engine speed. In the SG system, setting reference frequency, sensing generator output frequency and setting controller parameters are performed by performed by programming in a microcomputer, so a countermeasure for physical situations of control object is very easy. Futhermore, the SG system has following features; low initial installation cost, wide freedom of installation in engine room, advantage of application in existing ships, especially fishing boat with hydraulic fishing equipments.

  • PDF

Development Status and Structure Design of IoT Device for Farm Management using Sound Wave (음파를 이용한 IoT 농작물 관리시스템 개발현황 및 구조설계)

  • Ghil, Min-Sik;Kwak, Dong-Kurl;Choi, Shin-Hyeong
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.278-279
    • /
    • 2018
  • Due to the frequent occurrence of dangerous wild animals in rural or mountainous areas. it has been increasing damage of crops in every year. Fight bell or electric fence is typically installed to chase those wild animals. But there are problems that it is impossible to drive out birds and spends high installation and maintenance cost. In addition, it is inefficient to the risk of electric shock effect. In this study, the proposed system can drive out hazardous wildlife and birds regardless of installation location through realtime detection with the multi-sensing based IoT platform technology. This study showed a very large significance effect that can reduce crop damage by wildlife and birds.

  • PDF

The Photovoltaic generation control system using partial resonant method (부분공진기법을 이용한 태양광발전 제어시스템)

  • 고강훈;이현우;김영철;최광주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.16-22
    • /
    • 2000
  • This paper describes Transformer-less type utility interactive system that is combined with buck/boost chopper applying partial resonant method, which remove Transformer, and high efficient PWM inverter. Therefore, it is possible to make it lightweight, to cut down the cost, and to improve its reliability. What the merits of this system are that we can transmit arbitrary power arbitrary power to load and utility regardless of generating voltage magnitude of solar cell and we can always obtain high factor controlling by equal phase signal with utility.

  • PDF

A Study on Estimation Method of Outage Cost caused by Vulnerabilities of SCADA System (SCADA 시스템의 보안취약성을 고려한 정전비용 산정기법에 관한 연구)

  • Kim, Balho-H.;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.90-99
    • /
    • 2011
  • As power industry evolves into Smart Grid scheme, previously closed power systems are being integrated into public communication networks. It increases the controllability and efficiency of the system, but also accompanies many cyber threats having existed in the Internet to the SCADA system. Therefore it is required to apply security countermeasures to the Smart Grid, which brings about investment costs. There have been few approaches to assess risks from cyber attack especially in electric power industry. So this paper proposes a methodology to assess quantitative impacts of various types of cyber attacks to a power system, and also shows the feasibility of the method through a case study.

A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS (DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Cho, Hwi-Chang;Choi, Myeong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

A Study on the Electrical Fan Heater using High Efficiency Induction Heating (고효율 유도가열형 전기온풍기에 관한 연구)

  • Shin, Dae-Chul;Woo, Hyoung-Gyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.24-30
    • /
    • 2012
  • A proposed the electrical fan heater using induction heating is innovative system which applied IH(Induction Heating) magnetic induction heating generated from induction-heated metallic package and high-frequency power circuit technique for thermal converse technique. In this occurs not burning, so that the working environment and deterioration of products can be improved. The existing heater that low efficiency by heated resistance or using fossil fuel of coal, diesel, kerosene has problems about burden for high cost price. In this paper are compared efficiency the existing heaters and designed electrical fan heaters using 3[kW]-Class full-bridge resonant inverter. In addition, action analysis and application of system are discussed.

A Study on the Limit Analysis of the LED Lighting Subsidy Program Considering the Perspective of Individual Building Clients (건축주 입장을 고려한 LED조명 프로그램의 한계 분석 연구)

  • Hwang, Sung-Wook;Park, Jung-Sung;Chae, Woo-Kyu;Lee, Hak-Ju;Song, Il-Keun;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.18-25
    • /
    • 2013
  • Various DSM (Demand Side Management) programs have been developed and carried out to use the limited energy resources of human-beings reasonably. LED lighting is one of essential DSM programs and the development of technologies is ongoing vigorously. Recently, one-person households have been increased and the electricity consumption pattern is different with conventional households because residents live as a single. On the other hand, owners of the one-person households tend to not prefer to install high efficient appliances due to the cost increasement. Therefore, the existing DSM subsidy programs should be revaluated so that the owners decide to install high efficient appliances.