• Title/Summary/Keyword: Installation

Search Result 12,417, Processing Time 0.04 seconds

Electrical Safety Inspection for Empty Houses Using Leakage Current Measurement (누설전류 측정을 이용한 부재수용가의 전기안전 점검)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, Jin-Soo;Cho, Seong-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.260-263
    • /
    • 2006
  • The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installations for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

Crying Sea, The Sound Installation: Artistic Considerations for Coexistence between Human and Technology

  • Park, Jungsun;Wi, Hyeongseok;Park, Sungwoo
    • Journal of Multimedia Information System
    • /
    • v.9 no.1
    • /
    • pp.43-50
    • /
    • 2022
  • As the discourse on Anthropocene grows, this exploratory research investigates the interrelationship and interconnectivity between humanity and technology by analyzing a sound art installation created by the author. Crying Sea is a sound installation that uses plastic wastes collected from the shore to create symbolic narratives and artistic experience connecting humans, objects, and nature through interactive digital technology. In this installation, the audiences are guided to walk over the wastes, and the sounds created by the footsteps are recorded in real-time, which then are distorted and amplified into disturbing sounds through speakers filling up the room. In analyzing this artwork, three theories from technological, philosophical, and ecological backgrounds were used; specifically, Bernard Stiegler's pharmakon theory, Dona Haraway's cyborg manifesto, and Timothy Morton's dark ecology theory. A common factor revealed from all three theories by analyzing the Crying Sea is that humans, technologies, and all other entities within nature are interconnected and resonated. The awareness of this recursive relationship allows us to consider sustainable balancing.

THE DEVELOPMENT OF A CURTAIN WALL INSTALLATION ROBOT THROUGH THE ANALYSIS OF EXISTING CONSTRUCTION PROCESSES

  • Seung-Nam Yu ;Chong-Ho Choi ;Seung-Yel Lee;Chang-Soo Han
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.520-526
    • /
    • 2005
  • Automation in construction has been restricted to special classes of tasks. Curtain walls can be handled like standard construction materials; they are heavy but breakable, and are large but require precise installation. These characteristics make the installation of curtain walls ideal for robotic automation. There are two methods for developing construction robots: The first is approving the robot performance and applying it to the current construction methods. The second is admitting the limitation of the current robot technology and trying to optimize the current method of construction to apply the robot system. In this study, we derived the performance requirements of a curtain wall-installation robot. We also tested this robot at a real construction site and evaluated its performance. Finally, the results were analyzed, and we proposed additional research.

  • PDF

A Study on Siting of HVAC Offshore Substation for Wind Power Plant using Submarine Cable Cost Model (해저케이블 비용 모델을 이용한 HVAC 해상변전소 적정 위치 선정에 관한 연구)

  • Won, Jong-Nam;Moon, Won-Sik;Huh, Jae-Sun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.451-456
    • /
    • 2013
  • Development of the technologies for offshore wind power is proceeding actively and the installation capacity is continuously increasing because of its many advantages in comparison with the land wind power. Accordingly, project for Southwestern 2.5GW offshore wind power plant is in progress in Korea. Design of electric power systems for offshore wind power plant is very important due to its high investment and operational costs. Hence, it needs to be designed in order to minimize costs. This way can be employed in determining the installation location of offshore substation for HVAC wind power plant. According to the offshore substation site, MV inter-array cable and HV export cable lengths vary and they change a total cost regarding submarine cable. This paper represents cost models with variables which are MV inter-array cable and HV export cable lengths to locate the offshore substation for HVAC wind power plant. It is classified into submarine cable installation cost, reactive power compensator installation cost, ohmic losses, and unsupplied energy cost. By minimizing a total cost, an appropriate installation site of the offshore substation is determined.

Design and Implementation of Automatic Installation System for PDA (휴대 정보터미널을 위한 애플리케이션 자동설치 시스템의 설계 및 구현)

  • 나승원;오세만
    • The Journal of Society for e-Business Studies
    • /
    • v.8 no.3
    • /
    • pp.165-176
    • /
    • 2003
  • Instead of existing cell phones, PDAs are observed as leading wireless Internet devices recently Numerous applications are developed by extended usage of PDAs and it should be installed appropriately according to devices. Furthermore, when battery is discharged, all data stored in RAM(Random Access Memory) becomes obsolete. So it should be recovered or reinstalled from flash memory, backup media or something. In this paper, we present an automatic application installation system(PAIS : PDA Automatic Installation System) to solve problems that users have to install applications by themselves whenever it is necessary. With this system, users feel comfortable by saving time and effort to install each applications and application development companies save cost needed to make materials illustrating installation process. Consequently PAIS may flourish wireless Internet business.

  • PDF

The Expressive Characteristics of Fashion Installation in Henrik Vibskov Collection (헨릭 빕스코브 컬렉션에 나타난 패션 인스톨레이션의 표현 특성)

  • Ko, Hyunzin
    • Journal of the Korean Society of Costume
    • /
    • v.65 no.6
    • /
    • pp.133-147
    • /
    • 2015
  • The aim of this study is to review the creative fashion installation of Henrik Vibskov, Danish designer. Its intention is to contribute useful information for more innovative fashion presentation. As a research method, document and case study were performed and his collections from 2004 F/W to 2016 S/S were analyzed. In fashion installation, the designer puts objects in meaningful spaces in order to convey a certain message, to make an integrated artwork, and to interact with spectator. It has been used in fashion exhibitions, as well as in the set design of fashion performance and fashion show. The results were as follows. Henrik Vibskov's fashion installation has three features, which are 1)conceptual theme approach that communicates a twisted and metaphoric message, with a poetic and interesting show title, 2) surrealistic scenography that plays with fragmentation of the human body, clustering of plastic and symbolic objects, innovative color transformations, and visual trickery between figures and the background, and 3) setting for multisensory performance that makes spectators interact by making artistic objects and surroundings, which stimulates the five senses. Henrik Vibskov's fashion installation can exist as an independent artwork, and not just as a supporting piece for a fashion show. It has both artistic and fashionable values, and can be an effective fashion presentation communicating his conceptual fashion themes.

Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364 (IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰)

  • Kim, Doo-Ung;Ryu, Kyu-Sang;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

Trend analysis of open source distribution related to installation (오픈 소스 배포판의 설치 관련 동향 분석)

  • Jung, Sung-Jae;Bae, Yu-Mi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.9
    • /
    • pp.1932-1938
    • /
    • 2011
  • Public source code distribution form is done by mainly by limited class user and it was too hard to install. But companies are increasing who distribute software as open source, mass of people's interest also became high and it is coming about installation related methods have been changing. Not only traditional compile based installation, it is entrance on the stage of user friendly technique that is package installation, network based install, file execution after uncompression and cmake method to give easily to developer various platform support. This paper will analyze open source operating system Linux based public open source distributed application installation trend.

Simultaneous Implant Installation Using the Block Bone Graft (치조열에서 블록 골이식을 이용한 임플란트 동시 매식법)

  • Choung Pill-Hoon;Kang Nara;Hong Jong-Rak
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.5 no.2
    • /
    • pp.85-93
    • /
    • 2002
  • Simultaneous implant installation with bone graft was performed in 15 cases. Four cases were cleft alveolus patients. 56 implants were placed immediately with block bone grafts. 2 cases were cranial bone grafts and the others were iliac bone grafts. Three of 56 implants were lost(94.6% Survival rate). One of three was cleft alveolus case. The cleft alveolus patients with simultaneous implants installation showed functional and esthetic results without infraocclusion and positional changes. Bergland index was considered to be type I after 12 months later. Immediate implant installation with bone graft is one of choice of treatment in closing cleft alveolus hoping simultaneous implant installation could be related with function which might result in less resorption of graft. Functional and esthetic results are satisfaction ; there was no infraocclusion and positional changes.

  • PDF

A Study on Improvement of the Assessment Criteria for New and Renewable Energy Facilities in the G-SEED (G-SEED의 신·재생에너지시설 평가기준 개선 연구)

  • Kim, Wan-Young;Tae, Choon-Seob;Shin, U-Cheol;Yu, Chang-Kyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.43-50
    • /
    • 2015
  • The G-SEED encourages the installation of new and renewable energy facilities through assessments of the new and renewable energy installation rates. The government also regulates the installation rate of new and renewable energy facilities in the 'Project on new and renewable energy obligation in public installations'. The current criteria concerning the new and renewable energy facilities in the G-SEED are the result of an amendment made in July 2010. As over five years have passed since this amendment, the assessment criteria needs to be reenforced. To improve the current criteria, the calculation results of the installation rate of new and renewable energy facilities in the G-SEED were analyzed and compared to the corresponding calculation results of the 'Project on new and renewable energy obligation in public installations'. And an improved draft for the assessment criteria of the new and renewable energy facilities in the G-SEED was proposed.