• Title/Summary/Keyword: Instability Condition

Search Result 503, Processing Time 0.034 seconds

A Numerical Study on Nonlinear Dynamic Behavior of Diffusive-Thermal Instability in Diluted CH4/O2 Conterflow Diffusion Flames (희석된 메탄/산소 대향류 확산화염에서 확산-열 불안정으로 인한 화염의 비선형 동적 거동에 관한 수치해석)

  • Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.6
    • /
    • pp.688-696
    • /
    • 2004
  • Nonlinear dynamic behavior of diffusive-thermal instability in diluted CH$_4$/O$_2$ diffusion flames is numerically investigated by adopting detailed chemistry and transport. Counterflow diffusion flame is adopted as a model flamelet. Particular attention is focused on the pulsating-instability regime, which arises for Lewis numbers greater than unity, and the instability occurs at high strain rate near extinction condition in this flame configuration. Once a steady flame structure is obtained for a prescribed value of initial strain rate, transient solution of the flame is calculated after a finite amount of strain-rate perturbation is imposed on the steady flame. Transient evolution of the flame depends on the initial strain rate and the amount of perturbed strain rate. Basically, the dynamic behaviors can be classified into two types, namely non-oscillatory decaying solution and diverging solution leading to extinction. The peculiar oscillatory solution, which has been found in the previous study adopting one-step chemistry and constant Lewis numbers, is net observed in this study, which is attributed to both convective flow and preferential diffusion effects.

Numerical Study on Dynamic Behavior of Diffusive-Thermal Instability in $CH_4/O_2$ Conterflow Diffusion Flames (메탄/산소 대향류 확산화염에서 확산-열 불안정으로 인한 화염의 거동에 관한 수치적 연구)

  • Sohn, Chae-Hoon
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.95-101
    • /
    • 2004
  • Dynamic behavior of diffusive-thermal instability in diluted $CH_4/O_2$ diffusion flames is numerically investigated by adopting detailed chemistry and transport. Counterflow diffusion flame is adopted as a model flamelet. Particular attention is focused on the pulsating-instability regime, which arises for Lewis numbers greater than unity, and the instability occurs at high strain rate near extinction condition in this flame configuration. Once a steady flame structure is obtained for a prescribed value of initial strain rate. transient solution of the flame is calculated after a finite amount of strain-rate perturbation is imposed Oil the steady flame. Transient evolution of the flame depends on the initial strain rate and the amount of perturbed strain rate. Basically, the dynamic behaviors can be classified into two types, namely non-oscillatory decaying solution and diverging solution leading to extinction. The peculiar oscillatory solution. which has been found in the previous study adopting one-step chemistry and constant Lewis numbers, is not observed in this study, which is attributed to both convective flow and preferential diffusion effects.

  • PDF

Diffusive-Thermal Instability and Buoyancy-Driven Instability in Laminar Attached Free-jet Flames with DC Electric Fields (직류 전기장을 인가한 층류부착화염에서 물질-열 확산 및 부력에 의한 화염진동 비교에 관한 연구)

  • Han, Jong-Kyu;Yoon, Sung-Hwan;Park, Jeong;Yun, Jin-Han;Gil, Sang-In;Seo, Sang-Il;Kim, Young-Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.16 no.3
    • /
    • pp.41-51
    • /
    • 2011
  • In this paper, we describe the behavior of two self-excitations in laminar attached free-jet flames under the influence of DC electric fields, one of buoyancy-driven and the other of diffusion-thermal instability, established from the horizontal and vertical injection. In the horizontal injection with removed buoyancy effect, oscillating flames with the frequency of 1.3 - 7.4 Hz were observed in a certain condition with Lewis number more than unity. On the other hand, it was appeared Lewis number induced self-excitation as well as buoyancy-driven self-excitation in the vertical upward injection with DC electric fields. This behavior had frequency range of 1.6 - 9.4 Hz and was exhibited to attribute the buoyancy effect. Finally, a well-defined division about two self-excitations having similar frequency range is briefly discussed.

Surgical Experience with Posterior Atlantoaxial Transarticular Screw Fixation in Atlantoaxial Instability (환추-축추 불안정성에 있어서 후방 경관절 나사못 고정술에 대한 수술적 경험)

  • Cha, Seung Kyu;You, Chan Jong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.95-100
    • /
    • 2000
  • Objective : Posterior transarticular screw fixation is known to be one of the best surgical method for the atlantoaxial instability. We assessed the complication and operative risk in 15 patients. Patients and Methods : Between January 1997 and April 1998, 15 patients suffering from this condition were admitted to our institution. Atlantoaxial instability was caused by C1 or C2 fractures in 11, rheumatoid arthritis in 2, and os odontoideum in 2. This technique was used in the treatment of 13 patients and 2 patients was used in sublaminar wire fixation only. Bilateral C1-C2 screws were placed in 11 patients ; 2 patients had only one screw placed becauce of an anomalous vertebral artery and axial destruction. Follow-up period ranged from 5 to 20 months. Results : Most screws were positioned satisfactorily. One screw was malpositioned. No patients had neurological complications. Conclusion : Rigidly fixating C1-C2 instability with transarticular screws showed a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the transverse foramen on preoperative computed tomographic scans and by correctly using intraoperative fluoroscopy and surgeon's precaution.

  • PDF

A Study on Damping Characteristic under the Thermo-acoustic Condition using the Rijke Tube (Rijke Tube를 이용한 열환경에서의 음향공 감쇠 특성연구)

  • Kim, Geun-Cheol;Jeon, Jun-Soo;Kim, Joong-Il;Ko, Young-Sung;Kim, Hong-Jip
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.47-50
    • /
    • 2011
  • A Rijke tube which has an electric heater and a flow controller was designed and thermo-acoustic instability was induced by the Rijke tube. The thermo-acoustic instability was damped by a resonator and the damping characteristics were investigated and compared to room temperature acoustic test. Results show that decay time of the thermo-acoustic condition was increased by about 40% compared to that of room temperature acoustic test.

  • PDF

A Study on the Stability of Geared Systems Subjected to Torsional and Lateral Instability (비틀림진동 및 행진동을 받는 기어시스템의 안정화에 관한 연구)

  • Ro, S.H.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.3
    • /
    • pp.103-114
    • /
    • 1990
  • Many high speed mechanical systems incorporate gearing for speed reduction. This study investigates the stability of mulit-rotor geared systems supported on oil film bearings taking into consideration the coupling between torsional and lateral dynamics. The emphasis of the study is on the analysis of the interaction between the combined torsional and whirl insta- bilities. The feasility of inducing a lateral and the torsional instability to neutralize an anticipated unstable condition is investigated. The possibility of suppressing the instabilities by controlling the parameters of the oil film bearings is also considered.

  • PDF

ON THE IMPROVED INSTABILITY REGION FOR THE CIRCULAR RAYLEIGH PROBLEM OF HYDRODYNAMIC STABILITY

  • G. CHANDRASHEKHAR;A. VENKATALAXMI
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.1
    • /
    • pp.155-165
    • /
    • 2023
  • We consider circular Rayleigh problem of hydrodynamic stability which deals with linear stability of axial flows of an incompressible iniviscid homogeneous fluid to axisymmetric disturbances. For this problem, we obtained two parabolic instability regions which intersect with Batchelor and Gill semi-circle under some condition. This has been illustrated with examples. Also, we derived upper bound for the amplification factor.

A case study on the vibration by fluid induced instability at large steam turbine-generator (대형 터빈-발전기에서의 유체 불안정진동 해소사례)

  • Han, Seung-Woo;Noh, Chel-Woo;Kim, In-Chul;Joo, In-Gouk;Kim, Myong-Shik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1066-1071
    • /
    • 2007
  • This case study refers to turbine-generator with retrofitted turbine rotor. Vibration problem occurring after the retrofit was mainly due to high vibration from exciter side. However, repeated test run and operation during scheduled maintenance caused high vibration from generator bearing, and post-overhaul test run before turbine vibration correction caused oil whip on the bearing. This case study shows how to analyze vibration condition of high turbine generator vibration detected during the post-overhaul test run and vibration condition of offline and online data to reflect it on establishing maintenance schedule and overhaul correction procedure. Vibration data could be acquired during steady load operation or even with varying speed and load. Each data is important for machinery condition evaluation. This case study shows that the vibration data during extreme condition is the key factor in analysis, which helps to find the machinery problem.

  • PDF

A Case Study on the Vibration by Fluid Induced Instability at Large Steam Turbine-generator (대형 터빈-발전기에서의 유체 불안정진동 해소사례)

  • Han, Seung-Woo;Roh, Cheol-Woo;Yoo, Mu-Sang;Kim, In-Chul;Joo, In-Gouk;Kim, Myong-Shik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.2
    • /
    • pp.238-246
    • /
    • 2008
  • This case study refers to turbine-generator with retrofitted turbine rotor. Vibration problem occurring after the retrofit was mainly due to high vibration from exciter side. However, repeated test run and operation during scheduled maintenance caused high vibration from generator bearing, and post-overhaul test run before turbine vibration correction caused oil whip on the bearing. This case study shows how to analyze vibration condition of high turbine generator vibration detected during the post-overhaul test run and vibration condition of offline and online data to reflect it on establishing maintenance schedule and overhaul correction procedure. Vibration data could be acquired during steady load operation or even with varying speed and load. Each data is important for machinery condition evaluation. This case study shows that the vibration data during extreme condition is the key factor in analysis, which helps to find the machinery problem.

Walking Algorithm for Real-Time Stability of a Humanoid Robot Using Fuzzy Algorithm Under Uneven Terrain (퍼지 알고리즘을 이용한 불규칙한 지면에서 보행하는 휴머노이드 로봇의 실시간 보행 안정성 구현)

  • Cho, Hyoung-Rae;Kim, Jin-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.205-207
    • /
    • 2006
  • Since a humanoid robot inherently suffers from instability and always risks tipping itself over, or topping to the ground, it is necessary to ensure high stability and reliability of walk. An unexpected ground condition is one of the principal factors of instability. This paper proposes a walk stabilization method consisting of a Fuzzy algorithm and geometry under uneven terrain. The ground reaction forces that are measured by the FSR sensors on the sole are used to check the ground condition and the robot posture. The effectiveness of proposed method is verified by computer simulations.

  • PDF