• Title/Summary/Keyword: Inspector group

Search Result 15, Processing Time 0.025 seconds

Analyzing Cognitive Performance of Safety Risk Factors by Construction Industry Experience Using Eye Tracker (아이트래커를 활용한 건설업 경험에 따른 안전위험요인 인지 성과분석)

  • Nam, Jihyun;Mun, Junbu;Yun, Sungmin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.357-358
    • /
    • 2023
  • Due to recent enhance of safety law and regulations in construction sites, safety inspectors have been more required in construction sites. However, most of them are novice for safety inspection which have not enough experience and skill. Therefore, the novice safety inspector's performance on hazard recognition needs to be improved for effective safety management. The performance of safety inspection is influenced by the inspector's experience and background because the inspection is usually conducted by the inspector's eyes. Therefore, there is a difference in safety inspection performance between novice and experienced safety managers. This study aims to analyze the gap of risk perception between novice and experienced safety managers using quantitative visual data. For this objective, this study conducted eye tracking experiments for novice and experienced group to evaluate cognitive performance of safety risk factors. The results provides the level of safety awareness based on their experience in construction safety. The limitation of this study is a lack of the number of samples used in this study and did not consider the various characteristics of the participants. If these limitations are supplemented in future research, it can be used to develop safety education contents for novice safety managers.

  • PDF

The Effect of Increased Dilution Volume and Prolonged Infusion Time of Vancomycin on Incidence of Adverse Reactions through Peripheral Venous Cannulae (말초정맥을 통한 반코마이신희석과 주입시간연장이 부작용발생에 미치는 영향)

  • Oh, Myeong Ju;Kim, Mae Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.2
    • /
    • pp.196-208
    • /
    • 2000
  • The purpose of the study was to explore the effect of 2 hour infusion of vancomycin(1g) in 200ml of isotonic saline every 12 hour on the frequency of "red man syndrome", phlebitis and length of peripheral catheter placement of infected patients, in order to provide safe infusion method for reducing vancomycinin-duced RMS and phlebitis. The subjects of the study consisted of 16 hospitalized patients; 3 oncology and gastro-intestinal patients, 1 neurological patient, 6 thoracic surgical patients and 6 orthopedic patients, who had received vancomycin from July to October in 1999 at S-hospital. The dependent variables were the incidence of RMS, phlebitis and the length of peripheral catheter placement. The incidence of RMS was checked by an inspector at the first night whenever the infusion method of vancomycin was changed. RMS was observed every 15 minutes during an hour for symptoms of RMS such as itching, erythema, chest pain and systolic blood pressure. Incidence of phlebitis was assessed by inspector twice a day from the insertion of peripheral catheter to the removal of the catheter. The data were analyzed by percentage, mean, $X^2$-test, t-test, repeated ANOVA, and logistic regression analysis using the SPSSWIN program. The results are summarized as follows; 1. No significant difference was identified in frequency of RMS between the experimental group and control group. 2. There was no significant difference in the change of systolic blood pressure as the time goes on between the experimental group and control group. 3. The incidence of phlebitis was significantly lower in the experimental group than in the control group. 4. The length of peripheral catheter placement was significantly longer in the experimental group than in the control group. 5. Other drugs administrated with vancomycin didn't influence the occurrence of phlebitis. However, the infusion method of vancomycin influenced the occurrence of phlebitis. The results suggest that 2 hour infusion of vancomycin(1g) in 200ml of isotonic saline every 12 hours may decrease the incidence of phlebitis and increase the length of peripheral catheter placement compared to 1 hour infusion of vancomycin(1g) in 100ml of isotonic saline every 12 hours. However, it does not reduce the incidence of RMS.

  • PDF

Empirical Analysis for Improvement of Safety Management of Coastal Passenger Ship - Focusing on Safety Practitioners - (연안여객선 안전관리 개선을 위한 실증 분석 - 안전관리 실무 종사자 중심으로 -)

  • Kang, Min-gu;Kim, Hwayoung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.5
    • /
    • pp.511-518
    • /
    • 2019
  • This study aimed to extract the priority safety improvement factors for coastal passenger ships and analyze the perception gap between groups. To extract the improvement factors, we formed an expert group with maritime safety supervisors, passenger-ship safety inspectors (PSIs), and captains of passenger ships, and then conducted a Delphi survey. We found, using a hierarchy process, that the improvement factors were divided into three factors in Level 1 and ten factors in Level 2. For the relative importance analysis using the AHP (Analytic Hierarchy Process) model, we also formed two groups: an inspector group with maritime safety supervisors and PSIs, and an examinee group with safety managers, captains, and crews. Consequently, the factors of designation of public transportation for passenger ships and supporting the welfare of the crew were evaluated as the most important among the extracted factors. We conducted a t-test for the analysis of the perception gap between the two groups. Three perception gaps were found: increasing the inspection personnel, strengthening the qualification of the inspection personnel, and expanding the safety operation center. The result of this study will be useful for improving the safety policy of coastal passenger ships.

Merits and Demerits of the Inspection System introduced in Construction of City Planning Road: In Case of Crossing Road of the Aioiyama Green Area in Nagoya

  • Yutaka Okamura
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.178-184
    • /
    • 2004
  • The Yatomi - Aioiyama line is a city-planning road that was notified in 1957 and subsequently prepared by land readjustments. Currently, approximately 900m of road pass in the inside of the Aioiyama green area has not been constructed. The surveying briefing session for inhabitants was held in July 1992, the project was authorized by the Ministry of Land, Infrastructure and Transport in September 1993, and the project briefing session for inhabitants was held in September 1993. The site purchase has been completed. At the May 2000 briefing session, inhabitants of the area began voicing dissenting demanding the conservation of the natural environment of this green area. The inspector system serves as the third party, independent of both the administration and the inhabitants. Before finalizing the geometric line form of the road to be constructed, some surveys of animals and plants found along the walking trails carried out intensively in the northern area, which is approximately 50 ha, of the Aioiyama green area. The natural environment inspector submitted a plan for changing the geometric line form of the road decided upon by city planning, and it was approved by the city planning council. If the shelter structure or the retaining wall structure is adopted at the location where large slope faces are produced by excavation or landfill, and if the bridge structure is adopted at the place where stream-lines and walking trails intersect, it leads to a reduction of approximately $40\%$ in the areas for which change is planned. Furthermore, approximately $20\%$ of the area to be changed is restored by returning soil to the roof of the shelter.

  • PDF

GUI Environmental Controller Design with USB IF (USB IF를 이용한 GUI환경의 제어기 개발)

  • Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.449-454
    • /
    • 2003
  • In this paper, GU environmental controller is implemented with USB(Universal serial bus) IF(interface). Especially, the performance examination of ultrasound diagnostic device which connects external USB port with front panel is automatically inspected by VC++ examination program. The test program minimizes the operation of inspector with making the examined result audible or visible, and maximizes the productivity of custom device. The GUI environmental controller controls a standard keyboard, a track ball with dedicated buttons to emulate a standard two-button mouse, switches, rotary encoders, an analog potentiometer group, two alpha-numeric displays. and a touch screen; all of which generate events for the host.

  • PDF

Physiological and Histological Changes of Overfeeding-induced Obese Rainbow Trout Oncorhynchus mykiss (사료 과다공급으로 유도된 비만 무지개송어(Oncorhynchus mykiss)의 생리·조직학적 변화)

  • Park, Jiyeon;Roh, Heyong Jin;Park, Junewoo;Jeong, Dahye;Lee, Mu Kun;Kim, Do-Hyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.688-696
    • /
    • 2022
  • Obesity could cause immune-physiological disorders in fish. Yet, little is known about the impact of obesity on stress and histological responses. This study aimed to determine histological and physiological changes in and vulnerability of overfeeding-induced obese rainbow trout Oncorhynchus mykiss exposed to stress condition. Control, intermediate and overfed groups were fed at 1.5, 2.5 and 3.09% of their body weight per day, respectively, for eight weeks. Weight gain, body mass index, hepatosomatic index and serological parameters, and histology of liver were measured in five fish from each group at week 0, 2, 4, and 8. At week 8, 20 fish from each group were exposed to heat stress by increasing water temperature at a rate of 3℃ per day from 15 to 25℃ and maintaining the final temperature for 10 days. Overall, overfed fish showed significantly higher weight gain, body mass index, and serological parameters than those of fish in the other groups. Fish in the overfed and intermediate groups displayed multifocal infiltration of inflammatory cells in hepatic parenchyma. Mortality rate and serological parameters of fish in the overfed group exposed to heat stress were significantly higher than those of fish in the other groups, indicating increased vulnerability to environmental stress.

A Plastic BGA Singulation using High Thermal Energy of $2^{nd}$ Harmonic Nd:YAG Laser

  • Lee, Kyoung-Cheol;Baek, Kwang-Yeol;Lee, Cheon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.309-313
    • /
    • 2002
  • In this paper, we have studied minimization of the kerf-width and surface burning, which occurred after the conventional singulation process of the multi-layer BGA board with copper, polyethylene and epoxy glass fiber. The high thermal energy of a pulsed Nd:YAG laser is used to cut the multi-layer board. The most considerable matter in the laser cutting of the multi-layer BGA boards is their different absorption coefficient to the laser beam and their different heat conductivity. The cut mechanism of a multi-layer BGA board using a 2$^{nd}$ harmonic Nd:YAG laser is the thermal vaporization by high temperature rise based on the Gaussian profile and copper melting point. In this experiment, we found that the sacrifice layer and Na blowing are effective in minimizing the surface burning by the reaction between oxygen in the air and the laser beam. In addition, N2 blowing reduces laser energy loss by debris and suppresses surface oxidation. Also, the beam incidence on the epoxy layer compared to polyimide was much more suitable to reduce damage to polyimide with copper wire for the multi layer BGA singulation. When the polyester double-sided tape is used as a sacrifice layer, surface carbonization becomes less. The SEM, non-contact 3D inspector and high-resolution microscope are used to measure cut line-width and surface morphology.

Detection and Characterization of PCR-SSCP Markers of the Bovine Lactoferrin Gene for Clinical Mastitis

  • Zhou, Lei;Yang, Yuan-Yuan;Li, Zhong-Hao;Kong, Li-Juan;Xing, Guan-Dong;Di, He-Shuang;Wang, Gen-Lin
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.10
    • /
    • pp.1399-1403
    • /
    • 2006
  • A total of 80 cows, including 40 top mastitis resistant and 40 top mastitis susceptible animals as Group I and Group II, were selected from a population of 520 cows based on clinical mastitis occurrence. PCR-SSCP analysis on four fragments within the 5'region and two fragments of Exons 4,15 of bovine lactoferrin (bLF) revealed that four fragments-P1,P4,E4,E15-had polymorphisms which totally included six base mutations, and only two of them had significant differences in allele frequencies between resistant and susceptible groups, P1 (53.7% vs. 70.0%, p<0.05) and P4 (55.0% vs. 68.8%, p<0.05). Further study on these two promising markers combined with the milk performance traits of cows demonstrated that their selection would result in higher fat percentage (p<0.05), lower Somatic Cell Score (SCS) (p<0.05) and Clinical Mastitis Residuals (CMR) (p<0.01) indicating higher mastitis resistance and lower milk yield (p<0.05). The putative transcription factor binding sites in the 5'region were also studied by using MatInspector 7.2.2 software, and two signal pathways regulating the expression of bLF including the NF-${\kappa}B$ pathway and nuclear hormone receptor pathway were predicted.

A Folktale education that promotes communication between generations considering difference in cultural background (문화적 맥락의 차이에 따른 설화 향유의 한 양상과 세대 간 소통을 위한 설화 교육 시론)

Comparative study on the radiopacity of different resin-based implant cements (레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구)

  • Han, Kyeong-Hwan;Cheon, Ho-Young;Kim, Min-Su;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography. Materials and Methods: Four resin-based implant cements((Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA)) and control group (Elite Cement $100^{TM}$ (GC, Tokyo, Japan) ) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), ImageJ 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. Result: Among the 5 cements, Elite cement $100^{TM}$ (control group) showed the highest radio-opacity in all thickness. In the experimental group, $InterCem^{TM}$ had the highest radio-opacity followed by $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$ and Estemp $Implant^{TM}$. In addition, $InterCem^{TM}$ showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard. Conclusion: Among the implant resin-based cements tested in the study, $Premier^{(R)}$ Implant Cement and Estemp $Implant^{TM}$ did not show appropriate radio-opacity. Only $InterCem^{TM}$ and $Cem-Implant^{TM}$ 0.5 mm specimen had the proper radiopacity and met the experiment standard.