• Title/Summary/Keyword: Inspection frequency

Search Result 489, Processing Time 0.03 seconds

Dynamic Analysis of Structures under Moving Loads in Time and Frequency Domain (이동하중을 받는 구조물에 대한 시간영역과 주파수영역에서의 동적해석)

  • Kong, Min Sik;Yhim, Sung Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.87-94
    • /
    • 2007
  • A structural dynamic analysis can be divided into a time domain analysis and a frequency domain analysis. The time domain analysis makes use of a direct integration method or a mode superposition method and the frequency domain analysis applies a DFT method. Generally the DFT method is more effective method in case of calculating response of periodic excitation. But in case of transient excitation exact solution can not be acquired. So, by modifying the response or increasing the period accuracy of solution can be enhanced. Accordingly this study analyzed dynamic responses of structures under aperiodic moving load in time domain and frequence domain. Consequently it is concluded that exact solution would be get enough using DFT method by increasing the duration of free vibration or modifying the dynamic response.

Determination of Optimal Accelerometer Locations for Bridges using Frequency-Domain Hankel Matrix (주파수영역 Hankel matrix를 사용한 교량의 가속도센서 최적위치 결정)

  • Kang, Sungheon;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.27-34
    • /
    • 2016
  • A new algorithm for determining optimal accelerometer locations is proposed by using a frequency-domain Hankel matrix which is much simpler to construct than a time-domain Hankel matrix. The algorithm was examined through simulation studies by comparing the outcomes with those from other available methods. To compare and analyze the results from different methods, a dynamic analysis was carried out under seismic excitation and acceleration data were obtained at the selected optimal sensor locations. Vibrational amplitudes at the selected sensor locations were determined and those of all the other degrees of freedom were determined by using a spline function. MAC index of each method was calculated and compared to look at which method could determine more effective locations of accelerometers. The proposed frequency-domain Hankel matrix could determine reasonable selection of accelerometer locations compared with the others.

Risk Assessment Using RBI for Internal Corroded Pipelines in CDU Desulfurization Process (CDU 내 탈황공정의 내부부식 된 파이프라인을 대상으로 한 RBI기법을 이용한 위험성 평가)

  • Lim, Donghui;Jeong, Taehun;Lee, In-Dong;Jung, In Hee;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.33-39
    • /
    • 2019
  • in 2010s, many factories are operating without any safety guarantees due to the aging process. Although it is difficult to fundamentally solve the problem of aging process and equipment, Prevent risk by risk assessment in advance. This study targets the corrosion caused by sulfur in the piping in the CDU(Crude Distillation Unit) process desulfurization equipment and conducts the risk assessment by RBI(Risk Based Inspection) referring to API RP 581. RBI expresses the risk by combining frequency and consequence, and creates a risk matrix based on these expression. In this study, the hole size of the pipe was selected as Small and Medium, and the sensitivity of the frequency was selected as 'Low'. You can refer to the Risk Matrix created from the standard to evaluate the risk of corrosion of sulfur from pipes in the piping and to plan future accident prevention. Similarly, prevention of aging in a similar way can prevent large and small incidents that are not visible.

Spectral Estimation of EEG signal by AR Model (AR 모델을 이용한 뇌파신호의 스펙트럼 추정)

  • Ryo, D.K.;Kim, T.S.;Huh, J.M.;Yoo, S.K.;Park, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.114-117
    • /
    • 1990
  • EEG signal is analyzed by two methods, analysis by visual inspection of EEG recording sheets and analysis by quantative method. Generally visual inspection method is used in the clinical field. But this method has its limitation because EEG signal is random signal. Therefore it is necessary to analyze EEG signals quantatively to obtain more precise and objective information of neural and brain. In this paper, power spectrum of EEG signal was estimated by AR(AutoRegressive) model in the frequency domain. This process is useful as a preprocessing stage for tomographic brain mapping (TBM) at each frequency, band. As a method for estimating power spectral density of EEG signals, periodogram method, autocorrelation method. covariance method, modified covariance method, and Burg method are tested in this paper.

  • PDF

Hand Washing Awareness among Students in Seoul and Antibiotic Resistance of Staphylococcus aureus Isolated on Their Hands (서울지역 학생들의 손 씻기 의식과 학생들의 손에서 분리된 황색포도상구균의 항생제 내성에 관한 연구)

  • Lee, Hyang;Choi, Sung-Min
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.278-286
    • /
    • 2009
  • The total of 181 students in Seoul were made up questions to analysis hand washing awareness from 2007 to 2008. And their hands were sampled to isolate Staphylococcus aureus for testing antibiotic resistance. The average of hand washing frequency was $2.8{\pm}2.6$ per day in their schools. The rates of the students washing hands before eating food, after outdoor activity and after using bathroom were 22.2%, 24.4% and 49.4%, respectively. The rate of students washing hand less than 20 seconds was 64.4%. The students of 43.3% answered that they thought they were washing hands well. The middle school students were worse than elementary and high school students were aware of the frequency, duration and activity of hand washing. The isolation rate of S. aureus on the hands was 29.4%. The isolates were resitant to ampicillin (28.6%), chloramphenicol (6.1%), erythromycin (31.0%), gentamycin (2.0%), penicillin (79.6%) and tetracycline (6.1%) of 17 antibiotics tested. They were all sensitive to oxacillin and vancomycin.

A Method to Enhance Dynamic Range for Seismic Sensor Using ARMA Modelling of Low Frequency Noise and Kalman Filtering (지진계 저주파수 잡음의 ARMA 모델링 및 칼만필터를 이용한 지진계 동적범위 향상 방법)

  • Seong, Sang-Man;Lee, Byeung-Leul;Won, Jang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.43-48
    • /
    • 2015
  • In this study, a method to enhance the dynamic range of seismic sensor is proposed. The low frequency noise included in the measurement of seismic sensor is modelled as an ARMA(Auto Regressive Moving Average) model and the order and parameters of the model are identified through system identification method. The identified noise model is augmented into Kalmman filter which estimate seismic signal from sensor measurement. The proposed method is applied to a newly developed seismic sensor which is MEMS based 3-axis accelerometer type. The experiment show that the proposed method can enhance the dynamic range compared to the simple low pass filtering.

Dispersive Wave Analysis of a Beam under Impact Load by Piezo-Electric Film Sensor and Wavelet Transform (충격하중을 받는 보에서 압전 필름센서와 웨이브렛 변환을 이용한 문산파동의 해석)

  • Kwon., Il-Bum;Choi, Man-Yong;Jeong., Hyun-Jo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.215-225
    • /
    • 2001
  • Stress waves monitored on the surface of structures under various loading conditions can provide useful information on the structural health status. In this paper, stress waves are measured by several sensors when a steel beam is impacted by a ball drop. The sensors used include the piezo-electric film Sensor, the electrical strain gage, and the ultrasonic transducer, and special attention is given to the pieza film sensor. The wavelet transform is used for the time-frequency analysis of dispersive waves propagating in the beam. The velocities of the wave produced in the team due to the lateral impact is found to be frequency-dependent and identified as the flexural wave velocity based on the comparisons with the Timoshenko beam theory. A linear impact site identification method is developed using the flexural wave, and the impact sites of the beam can be accurately estimated by the piezo film sensors. It is found that the piezo film sensor is appropriate for sensing stress waves due to impact and for locating impact sites in the beam.

  • PDF

Health monitoring of pressurized pipelines by finite element method using meta-heuristic algorithms along with error sensitivity assessment

  • Amirmohammad Jahan;Mahdi Mollazadeh;Abolfazl Akbarpour;Mohsen Khatibinia
    • Structural Engineering and Mechanics
    • /
    • v.87 no.3
    • /
    • pp.211-219
    • /
    • 2023
  • The structural health of a pipeline is usually assessed by visual inspection. In addition to the fact that this method is expensive and time consuming, inspection of the whole structure is not possible due to limited access to some points. Therefore, adopting a damage detection method without the mentioned limitations is important in order to increase the safety of the structure. In recent years, vibration-based methods have been used to detect damage. These methods detect structural defects based on the fact that the dynamic responses of the structure will change due to damage existence. Therefore, the location and extent of damage, before and after the damage, are determined. In this study, fuzzy genetic algorithm has been used to monitor the structural health of the pipeline to create a fuzzy automated system and all kinds of possible failure scenarios that can occur for the structure. For this purpose, the results of an experimental model have been used. Its numerical model is generated in ABAQUS software and the results of the analysis are used in the fuzzy genetic algorithm. Results show that the system is more accurate in detecting high-intensity damages, and the use of higher frequency modes helps to increase accuracy. Moreover, the system considers the damage in symmetric regions with the same degree of membership. To deal with the uncertainties, some error values are added, which are observed to be negligible up to 10% of the error.

Variation of Eddy Current Signal According to the Defect Shape, Defect Depth and Radial Load in CFRP Tube (CFRP 튜브의 결함형상.결함깊이.레이디얼 하중에 따른 와전류 신호의 변화)

  • 송삼홍;안형근;이정순;오동준;송일;김철웅
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.2004-2011
    • /
    • 2004
  • The applicability of the ultrasonic C-scan inspection is restricted due to the deterioration of mechanical properties of specimen during the test. Therefore, the aim of this research is applied to Eddy Current (EC) test substitute for the C-scan inspection in CFRP tube containing defects. This research is to evaluate the EC signals for the inspection of CFRP tube containing various circular hole defects (20% to 100% depth to the specimen thickness) using the unloading specimen and radial loading specimen. This study was considered the following points; 1) Analysis of EC signals for the inspection of saw-cut defect and circular hole defect, 2) The evaluation of defect depths and EC signals relationship. 3) Variation of EC signal owing to the radial load. In conclusions, the high frequency such as 300∼500 kHz made it possible to the inspection of 40% to 100% defects. Particularly, in case of 20% defect, the EC signal was not detected due to the noise of micro-crack and delamination. While the depth of the hole defects were decreasing, the difference of the phase angle between unloading specimen and radial loading specimen was gradually increasing.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.