• 제목/요약/키워드: Insolation rate

검색결과 20건 처리시간 0.024초

태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究) (A Study on Characteristics of Fluid Flow on Direct Absorption Receiver from Solar Energy)

  • 박이동
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.13-28
    • /
    • 1984
  • Direct Absorption Receiver and Thermal Storage System is a complex problem. This paper describes only characteristic of fluid flow on the receiver. The fluid thicknesses of Molten Salts (Melting Point : $397^{\circ}C$) flowing on the receiver of modified protopype ($10m{\times}10m$) were calculated theorectically, changing the receiver slope from 60 degree to 85 degree (5 steps). The receiver temperatures were $430^{\circ}C$ at the top part and $950^{\circ}C$ at the low part. The flow thickness of the Molten Salts at the top part of the receiver are around 1.9mm in the case of maximum insolution ($50{\times}10^6$juoule/sec; 58.898kg/sec of flow rate) and 2.0mm at the low part. In the case of 3/10 of maximum insolation (flow rate = 17.669kg/sec) the flow thickness at the top part are around 0.9mm and 0.4mm at the low part, and in the case of 1/10 of maximum insolation (flow rate = 5.889 kg/see) the flow thickness at the top part are around 0.6mm and 0.3mm at the low part. From experimental measurements of a normal fresh water thickness flowing on the model plate ($12.7cm{\times}111.76cm$), around 0.8mm at the top part of the plate and around 0.7mm at the low part were obtained in the case of maximum insolation (flow rate = 0.12496 kg/see). In the case of 3/10 (flow rate = 0.03748 kg/see) and 1/10 (flow rate = 0.012496 kg/see) of maximum insolation, around 0.5mm and 0.4mm at the top part, and around 0.3mm and 0.2mm at the low part were obtained respectively. The reason why the thickness of the Molten Salts increase at the low part of the receiver only in case of maximum insolation is that decreasing rate of the viscosity of the Molten Salts is larger than decreasing rate of the density of the Molten Salts during temperature increase from the top to the low receiver plate and decrease of the fluid velocity in accordance with continuity principle. In all cases without the above maximum insolation, the thickness of the Molten Salts and the fresh water decreased at the low part of the plate because of gravity force effects rather than friction effects and of continuity principle. All simillar flow patterns were obtained through all cases of the insolation making an exception of only maximum insolation.

  • PDF

우리나라의 대기투과율과 대기오염과의 관계 (Relationship between Atmospheric Transmissivity and Air Pollution in Korea)

  • 이협희;김영섭;한영호
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.52-52
    • /
    • 1995
  • The temporal and spatial distribution of atmospheric transmissivity and depletion rate of solar radiation are investigated, and are compared to the concentration of several components of air pollution. The length of the data span is 11 years from 1983 to 1993. The data of radiation and sunshine rate recorded at 20 meteorological standard stations were used, and in order to investigate a relationship between the depletion rate of solar radiation and air pollution, the concentration data of air pollution observed in Seoul, Pusan, Taegu, Taejon and Kwangju were compiled from 1991 to 1993. Regression coefficient a and b vary from 0.100 to 0.209, from 0.464 to 0.691, and their means are 0.163 and 0.533, respectively. Climatological atmospheric transmissivity is ranged from 0.68 to 0.83, and its mean is 0.75. Atmospheric transmissivity is relatively low in Pusan, Taejon, Kwangju and Inchon which have large population and are highly industrialized. However, that in Chinju, Mokpo, Cheju and Sosan appears to be large compared to the aforementioned stations. Insolation rate of clear days varies from 0.71 to 0.58, and its mean is 0.63. Insolation rate of Kangnung and Chinju are higher than those of Seoul and Pusan by 5%. From the correlation coefficients between depletion rate of solar radiation and air pollution concentration, the most significant factors related to the depletion rate of solar radiation is appeared to be TSP followed by $SO_2$. Ozone shows a negative correlation, End $NO_2$ does not show a obvious correlation with the depletion rate of solar radiation.

우리나라의 대기투과율과 대기오염과의 관계 (Relationship between Atmospheric Transmissivity and Air Pollution in Korea)

  • 이협희;김영섭;한영호
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.437-446
    • /
    • 1995
  • The temporal and spatial distribution of atmospheric transmissivity and depletion rate of solar radiation are investigated, and are compared to the concentration of several components of air pollution. The length of the data span is 11 years from 1983 to 1993. The data of radiation and sunshine rate recorded at 20 meteorological standard stations were used, and in order to investigate a relationship between the depletion rate of solar radiation and air pollution, the concentration data of air pollution observed in Seoul, Pusan, Taegu, Taejon and Kwangju were compiled from 1991 to 1993. Regression coefficient a and b vary from 0.100 to 0.209, from 0.464 to 0.691, and their means are 0.163 and 0.533, respectively. Climatological atmospheric transmissivity is ranged from 0.68 to 0.83, and its mean is 0.75. Atmospheric transmissivity is relatively low in Pusan, Taejon, Kwangju and Inchon which have large population and are highly industrialized. However, that in Chinju, Mokpo, Cheju and Sosan appears to be large compared to the aforementioned stations. Insolation rate of clear days varies from 0.71 to 0.58, and its mean is 0.63. Insolation rate of Kangnung and Chinju are higher than those of Seoul and Pusan by 5%. From the correlation coefficients between depletion rate of solar radiation and air pollution concentration, the most significant factors related to the depletion rate of solar radiation is appeared to be TSP followed by $SO_2$. Ozone shows a negative correlation, End $NO_2$ does not show a obvious correlation with the depletion rate of solar radiation.

  • PDF

천리안 기상영상기 영상을 이용한 한반도 지역의 수평면 전일사량 추정 (Estimation of Global Horizontal Insolation over the Korean Peninsula Based on COMS MI Satellite Images)

  • 이정호;최원석;김용일;윤창열;조덕기;강용혁
    • 대한원격탐사학회지
    • /
    • 제29권1호
    • /
    • pp.151-160
    • /
    • 2013
  • 근래 들어 위성영상 기반의 한반도 지역 일사량 추정 연구가 활발히 진행되고 있으나 대부분의 연구들은 외국 위성영상을 이용하고 있다. 이에 본 연구에서는 국내 정지궤도 위성영상을 활용하여 한반도 지역의 일사량을 추정하는 것을 목적으로 한다. 입력데이터로는 국내최초의 정지궤도 위성인 천리안 기상영상기의 레벨1 데이터 및 레벨2 구름 영상, 그리고 미국 NASA의 OMI 영상을 이용하고, 물리모델식은 동아시아지역 일사량 추정에 보다 적합하다고 알려진 Kawamura 모델식을 적용한다. 2011년 5월~2012년 4월에 이르는 기간의 15분 간격 데이터를 이용하여 일일 수평면 전일사량을 추정하였으며, 이를 대한민국의 18개지점의 관측소 실측치와 비교하였다. 일일 일사량 추정값과 관측값 간의 $R^2$값은 0.86로서 높은 상관성을 나타냈으며, 월평균 일사량의 오차는 대부분의 지점에서 ${\pm}15%$ 이내였고 연평균 수평면 전일사량의 오차는 서울을 제외하면 약 -5~+5%의 분포를 보였다. 본 연구결과를 통해 한반도 지역의 일사량을 추정하는데 있어 천리안 기상영상기 영상이 활용 될 수 있음을 확인하였다.

태양열 난방시스템의 최적 유량에 관한 연구 (A Study on the Optimal Water Flow Rate of the Solar Heating System)

  • 성관제;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제12권1호
    • /
    • pp.2-11
    • /
    • 1983
  • The solar energy retention rate of a flat plate collector can be increased by increasing water flow rate through the collector which also increases the pumping energy incurred in obtaining that solar energy. The problem of optimal flow rate is formulated to fit within the framework of pontryagin's maximum principle and with a few simplifying assumptions, an optimal solution that can be easily implemented is obtaincd, The optimal solution is used in the simulation of a solar heating system using actual climatological data and the results are compared with that of on-off control. The result that not only the object function but, In some cases, also the solar energy retention rate the collector is increased. In is also found that the optimal control gets more advantageous as the solar insolation level gets lower, and also as tile cost of auxiliary heating fuel gets higher.

  • PDF

주택용 3kW 태양광발전시스템의 구성요소법 특성 분석 (Characteristics analysis of Residential 3kW PV System)

  • 변문걸;박정국;임홍우;이강연;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1181-1182
    • /
    • 2006
  • The solar power system comprises a solar battery that directly converts light energy to electrical energy with a photovoltaic effect and a power converter system, that is, inverter that converts direct current power, which is generated from solar battery to common alternating current. In this paper, database was constituted through remote monitoring supervision measurement for the long-time positive operation of 3kW solar power system installed within the solar energy positive research complex of Chosun University. As a result of analyzing the reduction of the efficiency of solar battery and inverter that are compositional components of PV system through an analysis on the acquired data, the PV output was proven over 65% of the total output when insolation intensity exceeded 600W/m2 in 2005, and the array conversion efficiency dropped much more than rating; meanwhile, insolation intensity dropped below 600W/m2. Therefore, it has been demonstrated that approximately 35% of the entire amount of PV output operated under the condition that the inverter efficiency rate dropped rapidly by 60 to 70%.

  • PDF

전면형 이중외피의 절기별 운용성능 분석 (Analysis for Seasonal Operation Performance of Multistory Facade)

  • 임혜진;조수;성욱주;임상훈;한찬훈
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.111-120
    • /
    • 2012
  • In this study, to present the data in the internal thermal condition of Double skin facade were measured internal temperature and inlet and outlet openings wind speed of double skin facade. Measurements were similar to temperatures in the upper double skin facade. Especially in summer, temperature stratification is through to be unfulfilled seamlessly despite inlet and outlet openings open. Double skin facade inlet and outlet openings of the air flow rate was slower outlet openings of the air flow rate than inlet openings of the air flow rate.

Experimental and mathematical evaluation of solar powered still equipped by nano plate as the principle stage of zero discharge desalination process

  • Jadidoleslami, Milad;Farahbod, Farshad
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.147-161
    • /
    • 2016
  • To start with, finding a sustainable method to produce sweet water and electricity by using renewable energies is one of the most important issues at this time. So, experimental and theoretical analysis of the performance of a closed solar powered still, which is jointed to photovoltaic cells and vacuum pump and equipped by nano plate, as the principle stage of zero discharge desalination process is investigated in this project. Major goal of this work is to reuse the concentrated brine of the Mobin petrochemical complex in order to produce potable, sweet water from effluent saline wastewater and generating electricity in the same time by using solar energy instead of discharging them to the environment. It is observed the increase in brackish water temperature increases the average daily production of solar desalination still considerably. Therefore, the nano plate and vacuum pump are added to augment the evaporation rate. The insolation rate, evaporation rate, the average brackish temperature, ambient temperature, density are investigated during a year 2013. In addition to obtain the capacity of solar powered still, the highest and lowest amount of water and electricity generation are reported during a twelvemonth (2013). Results indicate the average daily production is increased 16%, which represents 7.78 kW.h energy saving comparing with traditional solar still.

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

부산지역 여름철 고농도 오존 발생의 사례 연구 (Case Study for High Ozone Episode day during Summertime in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제12권4호
    • /
    • pp.303-313
    • /
    • 2003
  • This study was carried out to survey the high ozone episode of summertime in Busan. The selected day was July 18, 1999 and August 24, 2001 which recorded exceed to 12ppb/hr at 3 station in Busan simultaneously. In case July 18, 1999, thick cloud and variable wind made weak ozone concentration during morning hour. And increase of ozone concentration by revolution of mixed layer for morning hour did not occur in this case study day. Photochemical reaction by strong radiation after 1100LST made sharp increase rate of ozone concentration(50ppb/hr). In case August 24, 2001, the meteorological condition of this day was not general wind with gradient force, very clear day with less cloud amount, high insolation and sunshine. Dongsamdong, Beomcheondong, Daeyeondong, and Sinpyeongdong had double peak which twice maximum concentration in the early afternoon and late afternoon. Ozone concentration of this day was in inverse proportion to Nitrogen oxide strongly. Ozone concentration exceed to 60ppb/hr occurred at 1400LST, continued to 2300LST.