• Title/Summary/Keyword: Inside outside test

Search Result 248, Processing Time 0.031 seconds

A Study on Finned Tube Used in Turbo Refrigerator( I ) -for Condensation Hear Transfer- (터보 냉동기용 핀튜브에 관한 연구 ( I ) - 응축 열전달에 관하여 -)

  • Cho, Dong-Hyun;Han, Kyu-Il;Kim, Si-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.1
    • /
    • pp.31-44
    • /
    • 1993
  • Through the early 1900's, the evolution of the surface condenser was closely tied to the development of steam engine and the turbine. As the chemical and petroleum industries evolved in the 1900's, the use of surface condensers in many different processes. Today, industry uses condensers in many shapes and sizes. The actual condensation process occurs on the outside surface of tubes. The nature of this surface geometry affects the condenser's heat transfer performance. The first condensers were built with plain tubes. As tube manufacturing techniques advanced, manufacturers started making tubes with integral fins. In the 1940's, fin densities were limited to about 600 to 700 fins per meter(fpm) because of manufacturing procedure. Today new manufacturing techniques allow production of tubes with fin densities ranging from 750 to 1600 fpm. The integral-fin tubes investigated in this paper are nominally 19 mm diameter. Eight tubes have been used with trapezodially shaped integral-fins having fin density from 748 to 1654 fpm and 10, 30 grooves. For comparison, tests are made using a plain tube having the same inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Betty and Katz's theoretical modelis is used to predict the R-11 condensation coefficient on horizontal integral-fin tubes having 748, 1024 and 1299 fpm. Experiments are carried out using R-11 as working fluid. The refrigerant condensates at a saturation state of $30^{\circ}C$ on the outside tube surface cooled by coolant. The amount of noncondensable gases present in the test loop is reduced to a negligible value by repeated purging. For a given heat input to the boiler and given cooling water flow rate, all test data are taken at steady state. The observed heat transfer enhancement for the finned and grooved tubes significantly exceeded that to be expected on grounds of increased area. For the eight fin tubes and one plain tube tested, the best performance has been obtained with a tube having a fin density of 1299 fpm, and a fin bight of 1.2mm and 30 grooves.

  • PDF

Analysis on Consolidation Behavior of Soft Ground with Reactive Drain Pile (반응성 배수파일이 타설된 지반의 압밀거동 분석)

  • Kim, Beomjun;Oh, Myounghak;Yune, Chanyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • Geotechnical evaluation on the reactive drain pile which can achieve simultaneously both the soft ground improvement and the remediation of contaminated pore water in reclamation site was performed. Applicability of steel-making slag used as a inside reactive material was confirmed. To investigate the consolidation characteristics of the soft ground improved by reactive drain pile, testing devices to form and install the reactive drain pile were developed and laboratory tests were performed according to the existence of outside sand drain and the length of impermeable barrier. Test results showed that the consolidation time was decreased as the shortening of impermeable barrier. However, the effect of outside sand drain on consolidation time was dominant compared with the length of impermeable barrier.

The research regarding an information system risk management process characteristics (정보시스템 위험관리 프로세스 특성에 관한 연구)

  • Kim, Tai-Dal;Lee, Hyung-Won
    • The KIPS Transactions:PartD
    • /
    • v.14D no.3 s.113
    • /
    • pp.303-310
    • /
    • 2007
  • Information system failure is various such as program test unpreparedness, physical facilities for damage prevention unpreparedness from simple software error. Although cross is trifling the result causes vast damage. Recently, became difficult by simple outside security system to solve this problem. Now, synthetic countermove establishment and suitable confrontation connected with danger came in necessary visual point about general Information Technology of enterprise. In connection with, in this paper, various informations and system and control about data that can happen information inside and outside considering integrity for IT resource, solubility, confidentiality within organization studied about special quality to model synthetic Risk Management System that can of course and cope in danger.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

Comparison of map display styles of vehicle navigation system on human factors (차량 항법장치의 화면표시형태에 대한 인간공학적 비교)

  • Jung, Beom-Jin;Baek, Seung-Ryul;Kim, Gi-Beom;Park, Beom
    • Proceedings of the ESK Conference
    • /
    • 1995.10a
    • /
    • pp.208-213
    • /
    • 1995
  • The vehicle navigation system is developed for helping driver to retrieve driving information more easily and lastly. Navigation System informs driver many pieces of driving information - roadway structure and system, on-line traffic condition, the position of vehicle, route guidance, destination and other infor- mation service. As the style of information is diverse and the amount of information is large, driver may have mental and visual overload. The display of information can disturb the driver's attention and this can cause accidents. This state is caused by the defect of human-machine interactions. When the navigation system is designed, human factors - cognitive, judgment, operating -must be considered. The display style must be designed simply and easily, not to be obstacle of human - machine interface. In this study, outside- in view display style and inside-out view display style are compared each other. Tow factors are measured. One is cognitive factor-time of cognition on information that is displayed by screen display, cognition error rate. The other is image of screen display - subject's feeling about several styles of display, degree of subject's preference. The prototype of roadway is four kinds -Cross, T-cross and O-cross. Roadway display for test is taken from paper maps. Traffic condition display style, vehicle position display style and route guidance display style are taken from current display style. Traffic condition display style is symbol. vehicle position display style and route guidance display style are described as color and symbol. The test on screen display is implemented doing given tasks. Then the test is analyzed statistically. The result of test analysis gives the guideline to the designer for the map display of the vehicle navigation system.

  • PDF

Comparison of Map Display Styles of Vehicle Navigation System on Human Factors (자동차 항법장치의 화면표시형태에 대한 인간공학적 비교)

  • Jeong, Peom-Jin;Paek, Sung-Lyeol;Kim, Ki-Peom;Park, Peom
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.18 no.36
    • /
    • pp.49-59
    • /
    • 1995
  • The vehicle navigation system is developed for helping driver to retrieve driving information more easily and fastly. Navigation System informs driver many pieces of driving information - roadway structure and system, on-line traffic condition, the position of vehicle, route guidance, destination and other information service. As the style of information is diverse and the amount of information is large, driver may have mental and visual overload. The display of information can disturb the driver's attention and this can cause accidents. This state is caused by the defect of human-machine interactions. When the navigation system is designed, human factors - cognitive, judgment, operating - must be considered. The display style must be designed simply and easily, not to be obstacle of human -machine interface. In this study, outside-in view display style and inside-out view display style are compared each other. Two factors are measured. One is cognitive factor-time of cognition on information that is displayed by screen display, cognition error rate. The other is image of screen display - subject's feeling about several styles of display, degree of subject's preference. The prototype of roadway is four kinds - Cross, T-cross, Y-cross and O-cross. Roadway display for test is taken from paper maps. Traffic condition display style, vehicle position display style and route guidance display style are taken from current display style. Traffic condition display style is symbol. Vehicle position display style and route guidance display style are described as color and symbol. The test on screen display is implemented doing given tasks. Then the test is analyzed statistically, The result of test analysis gives the guideline to the designer for the map display of the vehicle navigation system.

  • PDF

A Shaking Table Test for an Re-evaluation of Seismic Fragility of Electrical Cabinet in NPP (원전 전기캐비넷의 지진취약도 재평가를 위한 진동대 실험)

  • Kim, Min-Kyu;Choi, In-Kil
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.295-305
    • /
    • 2011
  • In this study, a seismic behavior of electrical cabinet system in Nuclear Power Plants(NPPs) was evaluated by the shaking table test. A 480V Motor Control Centers(MCCs) was selected for the shaking table test, and a real MCC cabinet for the Korea Nuclear Power Plant site was rented by manufactured company. For the shaking table tests, three kinds of seismic input motions were used, which were a US NRC Reg. guide 1.60 design spectrum, a UHS spectrum and PAB 165' floor response spectrum(FRS). Especially, the UHS input motion was selected for an evaluation of structural seismic amplification effects, three directional accelerations were measured at three points outside on the cabinet system and also that of the incabinet response amplification, accelerations were measure at two points which were mounted in electrical equipment such as relay. Seismic amplification effect is determined at the outside and inside of a cabinet as input seismic motion, and compared to the results which are calculated by analytical method based on NUREG/CR-5203.

Development of Adsorptive Permeation Membrane (APM) and Process for Separation of $CO_2$ from gas mixtures (이산화탄소 분리를 위한 흡착투과막 및 공정 개발)

  • Yeom, Choong Kyun;Ahn, Hyo Sung;Kang, Kyeong Rok;Kim, Joo Yul;Han, Jin-Soo;Kwon, Keun-Oh
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.409-417
    • /
    • 2013
  • Adsorptive permeation hollow fiber membrane (APM) has been developed for effectively separating $CO_2$ from gas mixture. Inside the APM, zeolite 13X particles were uniformly dispersed without covering their surfaces by a symmetric porous structure of polypropylene lattice. In this study, $CO_2/N_2$ mixture was used as a simulated gas mixture. Separation was achieved by adsorbing $CO_2$ on the zeolite particles in the APM and then permeating $N_2$ into permeate side in passing all the feed gas through the APM. Adsorptive permeation tests were carried out with a set of APM modules, and the adsorptive permeation performances of the modules were analyzed from the test results. After saturation of the adsorbent with $CO_2$, the APM was regenerated by desorption of $CO_2$ from it through vacuuming both inside of outside of the APM hollow fiber, and the regeneration process of the APM by vacuuming was discussed in terms of regeneration efficiency and energy consumption.

Investigation of interference current distribution in a long line scallop cage aquaculture (수하식 큰가리비 양식의 채롱간 조류의 흐름 간섭현상 규명)

  • Kim, Hyun-Young;OH, Bong-Se;Cha, Bong-Jin;Park, Mi-Seon
    • The Korean Journal of Malacology
    • /
    • v.30 no.3
    • /
    • pp.273-279
    • /
    • 2014
  • The mass mortalities have been occurring of Korean scallop Patinopecten yessoensis from 1997's to now in Korea east sea. Cages behavior and interference effect (common name; curtain effect) between scallop cages were investigated in culture grounds on the eastern coastal waters of Korea for understand to mechanism of rising about mass mortalities of Korean scallop quickly. The first experiment was carried out in circulating water channel to assess inclination angel from relationship between velocity and cages interval, velocity with culture cages position. An angle of inclination of scallop culture cages were 94.6 to 92.3 degree under a several velocity which were from 0.1 m/s and 131.9 to 118.1 degree under 0.5 m/s with cages interval were 1 m, 94.3 to 91.0 degree under velocity is 0.1 m/s and 133.2 to 122.4 degree under 0.5 m/s with cages interval were 1.5 m and 94.6 to 96.4 degree under velocity is 0.1 m/s and 131.7 to 131.8 under 0.5 m/s with cages interval were 2 m. The second experiment was designed to prove the tank test. Velocities were measured inside and outside of the scallop culture ground at eastern sea of Korea. The velocity of inside of the culture was the slowest as 0.1m/s. In this result, interference between former cage and after cage was occurred.

The Jet-fan Model Test for a Road Tunnel Ventilation (도로터널 제트팬 모형 실험)

  • Ryu, Jae-Hong;Yoo, Young-Ho;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.630-640
    • /
    • 2003
  • As tunnel ventilation has recently been playing a major role in the tunnel construction and maintenance, longitudinal ventilation systems with jet fans have been utilized a great deal because they are economical and effective. However, due to the length of tunnels and heavy traffic, it is hard to take the field measurements. In this study, therefore, the computer simulation and the model experiment of producing a wind tunnel were carried out simultaneously and the results were compared. The ultimate objective of this research was to interpret the air flow pattern inside the tunnel with a jet-fan was set up, and to offer the useful data for jet-fan installation and operation. The experiment was carried out with varying the jet-fan diameters, location of installation, the discharge velocity. Result showed that as the initial static pressure came up with the negative pressure, the tunnel air flowed into the inside of tunnel from outside due to the entrainment-effect and the backflow-phenomenon by separation-effect was observed in the lower half part of the tunnel. As the jet-fan was getting closer to the tunnel wall, the entrainment-effect caused by the interaction with the wall was increased; however, the mixing distance and irregular flow section became longer, and also the air pressure loss generated by wall friction was large.