• 제목/요약/키워드: Insertion depth

검색결과 144건 처리시간 0.024초

복강내침술과 관련 혈위의 자침 깊이에 대한 고찰 (Review on Intraperitoneal Acupuncture and Needling Depth)

  • 김소연
    • Korean Journal of Acupuncture
    • /
    • 제40권3호
    • /
    • pp.55-61
    • /
    • 2023
  • Objectives : To review the needling depth, therapeutic and adverse effects of intraperitoneal acupuncture and related acupoints. Methods : Studies and reports from the literature, Korean medical health insurance data and databases were searched and selected. Results : The depth of needle insertion for acupoints related to intraperitoneal acupuncture has been documented to range from 0.9 to 10.5 cm depending on the acupoints and literature. In studies of safe needling depth, the justice of safe needling depth varied from study to study, but was generally based on the peritoneum, and the depth varies by patient age, sex, body type, and weight. Clinical studies in China have shown good efficacy and no side effects of abdominal long needle acupuncture, but there have been case reports of adverse events following abdominal acupuncture. Conclusions : To ensure both therapeutic effectiveness and safety of intraperitoneal acupuncture, It is necessary to utilize the ultrasound in clinical practice and conduct related research.

이중원뿔 투영을 이용한 거리의 추정 (Depth estimation by using a double conic projection)

  • 김완수;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1411-1414
    • /
    • 1997
  • It is essential to obtain a distane informaion in order to completely execute assembly tasks such as a grasping and an insertion. In this paper, we propose a method estimating a measurement distance from a sensor to an object through using the omni-directional image sensing system for assembly(OISSA) and show its features and feasibility by a computer simulation. The method, utilizing a forwarded motion stereo technique, is simple to search the corresponding points and possible to immediatiely obtain a three-dimensional 2.pi.-shape information.

  • PDF

Estimation of optimal nasotracheal tube depth in adult patients

  • Ji, Sung-Mi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권4호
    • /
    • pp.307-312
    • /
    • 2017
  • Background: The aim of this study was to estimate the optimal depth of nasotracheal tube placement. Methods: We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch were measured. To estimate optimal tube depth, correlation and regression analyses were performed using clinical and anthropometric parameters. Results: The mean tube depth was $28.9{\pm}1.3cm$ in men (n = 62), and $26.6{\pm}1.5cm$ in women (n = 48). Tube depth significantly correlated with height (r = 0.735, P < 0.001). Distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch correlated with depth of the endotracheal tube (r = 0.363, r = 0.362, and r = 0.546, P < 0.05). The tube depth also correlated with the sum of these distances (r = 0.646, P < 0.001). We devised the following formula for estimating tube depth: $19.856+0.267{\times}sum$ of the three distances ($R^2=0.432$, P < 0.001). Conclusions: The optimal tube depth for nasotracheally intubated adult patients correlated with height and sum of the distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch. The proposed equation would be a useful guide to determine optimal nasotracheal tube placement.

Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

  • Uzunoglu-Ozyurek, Emel;Karaaslan, Hakan;Turker, Sevinc Aktemur;Ozcelik, Bahar
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.2.1-2.10
    • /
    • 2018
  • Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

Evaluation of mandibular buccal shelf characteristics in the Colombian population: A cone-beam computed tomography study

  • Escobar-Correa, Natalia;Ramirez-Bustamante, Maria Antonia;Sanchez-Uribe, Luis Alejandro;Upegui-Zea, Juan Carlos;Vergara-Villarreal, Patricia;Ramirez-Ossa, Diana Milena
    • 대한치과교정학회지
    • /
    • 제51권1호
    • /
    • pp.23-31
    • /
    • 2021
  • Objective: To evaluate the mandibular buccal shelf (MBS) in terms of the angulation and bone depth and thickness according to sex, age, and sagittal and vertical skeletal patterns in a Colombian population using cone-beam computed tomography (CBCT). Accordingly, the optimal site for miniscrew insertion in this area was determined. Methods: This descriptive, retrospective study included 64 hemi-arches of 34 patients. On CBCT images, the angulation, buccal bone depth (4 and 6 mm from the cementoenamel junction [CEJ] of MBS), and buccal bone thickness (6 and 11 mm from the CEJ of MBS) were measured at the mesial and distal roots of the mandibular first and second molars. Results: There were no statistically significant differences in the angulation, depth, and thickness of MBS between male and female patients. The values for the bone around the distal root of the mandibular second molar were significantly greater than the other values. The osseous characteristics were significantly better in participants aged 16-24 years. Class III patients exhibited the best osseous characteristics, with the bone depth at 6 mm being significantly different from that in Class I and Class II patients. Although values tended to be greater in patients with low angles, the difference was not statistically significant. Conclusions: MBS provides an optimal bone surface for miniscrew insertion, with better osseous characteristics at the distal root of the mandibular second molar, 4 mm from CEJ. Adolescent patients, Class III patients, and patients with a low angle exhibit the most favorable osseous characteristics in the MBS area.

LTCC를 이용한 RF MEMS 소자의 실장법 (LTCC-Based Packaging Technology for RF MEMS Devices)

  • 황근철;박재형;백창욱;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1972-1975
    • /
    • 2002
  • In this paper, we have proposed low temperature co-fired ceramic (LTCC) based packaging for RF MEMS devices. The packaging structure is designed and evaluated with 3D full field simulation. 50 ${\Omega}$ matched coplanar waveguide(CPW) transmission line is employed as the test vehicle to evaluate the performances of the proposed package structure. The line is encapsulated with the LTCC packaging lid and connected to the via feed line. To reduce the insertion loss due to the packaging lid, the cavity with via post is formed in the packaging lid. The performances of the package structure is simulated with the different cavity depth and via-to-via length. Simulation results show that the proposed package structure has reflection loss better than 20 dB and insertion loss lower than 0.1 dB from DC to 30 GHz with the cavity depth and via-to-via length of 300 ${\mu}m$ and 350 ${\mu}m$, respectively. To realize the designed package structure, the cavity patterning is tested using the sandblast of LTCC.

  • PDF

Wet Oxygen 분위기로 제작한 z-cut $Ti;LiNbO_3$도파로 광특성 및 두께에 따른 삽입손실 (z-cut $Ti;LiNbO_3$ Waveguide Optical Properties and lnsertion Loss As a Function of $Ti;LiNbO_3$thickness Fabricated by wet Oxygen Atmosphere)

  • 김성구;윤형도;윤대원;박계춘;정해덕;이진
    • 한국전기전자재료학회논문지
    • /
    • 제11권10호
    • /
    • pp.903-910
    • /
    • 1998
  • Ti:LiNbO$_3$ optical waveguides have been fabricated by Ti-diffusion in wet oxygen atmosphere. The fabrication conditions of furnace temperature, diffusion time and bubbler temperature were 105$0^{\circ}C$, 8 hours and 9$0^{\circ}C$, respectively and Ti thickness was varied from 700$\AA$ to 1500$\AA$. In this paper, the nearfield patterns, mode sizes (hirizontal/vertical) and insertion loss of waveguides were discussed at wavelength 1550 nm ad function of Ti thickness. With the planar waveguide, the effective index change and diffusion depth were calculated at 632.8nm using the prism coupling method. From these results, the best Ti thickness in our conditions seems like to by 1200$\AA$~1300$\AA$.

  • PDF

고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계 (Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

  • Di Stefano, Danilo Alessio;Perrotti, Vittoria;Greco, Gian Battista;Cappucci, Claudia;Arosio, Paolo;Piattelli, Adriano;Iezzi, Giovanna
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.227-235
    • /
    • 2018
  • PURPOSE. Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. RESULTS. Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

인체 치간부위 치조골 결손에 사용된 합성골의 효과에 관한 연구 (THE EFFECTS OF POROUS HYDROXYAPATITE AND NATURAL CORAL ON HUMAN PERIODONTAL DEFECTS)

  • 심정민;최광춘;손성회
    • Journal of Periodontal and Implant Science
    • /
    • 제23권2호
    • /
    • pp.345-351
    • /
    • 1993
  • Various alloplastic materials have been used on the periodontally diseased ossous defects. Hydroxyapatite, which is used the most common alloplastic material is a non-resorbable form of calcium phosphate and natural coral which is a biodegradable by carbonic anhydrase in osteoclast was introduced recently. The purpose of the present study was to evaluate the clinical effects of porous hydoxyapatite and natural coral on the human periodontal defects. Four males and three females who had adult periodontitis were selected for this study. The teeth that had similar bone loss radiographically and periodontal pocket deeper than 5mm were selected. Gingival recession, pocket depth, plaque index(Silness & Loe), sulcus bleeding index and tooth mobility (measured by Periotest$^{(r)}$) were examined before graft. Before insertion of alloplastic materials, the depth from CEJ to bone crest and from CEJ to base of the osseous defect was recorded. Porous particulate hydroxyapatite(Interpore 200$^{(r)}$, A group) was place on the defect and natural coral(Biocoral$^{(r)}$, B group) was placed on the defect of the opposing tooth. Six months post-surgically the same parameters were recorded by reentry procedures. A and B group showed 0.6mm of mean recession. Mean reduction of pocket depth were 5mm for A group and 4.9mm of B group. Reduced SBI and tooth mobility were recorded. Osseous defect fills of the original defects were 2.9mm for A and 3mm for B group. Percentage defect fills were 71% for A and 59% for B group. The difference of defect fill between pre- and post-insertion was statstically significant(p<0.05). But the difference between the two groups was not significant statistically(p<0.05). The clinical impression at 6 month re-entry and the numerical date indicate that natural coral as well as porous particulate hydoxyapatite has a definite potential as an alloplastic implant in the treatment of periodontal osseous defects.

  • PDF