• Title/Summary/Keyword: Insertion angle

Search Result 140, Processing Time 0.024 seconds

A Ku-Band Reduced Height Waveguide to Microstrip Mode Converter with a Short Transition Length (짧은 천이길이를 갖는 Ku-대역 감소단축도파관 대 마이크로스트립 모드 변환기)

  • Oh, Hyun-Seok;Yeorn, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1435-1444
    • /
    • 2008
  • In this paper, we designed a reduced height waveguide(WG) to microstrip mode converter with a short transition length. The mode converter is composed of a mode converter using E-plane probe and a modified impedance transformer. The mode converter was designed using a probe shorted to top of a 50 ohm ridge WG. The modified impedance transformer was designed to connect the mode converter to the reduced height WG. For wide bandwidth operation, the coupling of the two parts was tuned. The structure of the mode converter was optimized for low loss and wide bandwidth, and the optimized mode converter was fabricated. The performance of the mode converter was extracted using the thru and line S-parameters for back-to-back connections, and the connector loss was calibrated. The mode converter has a right angle structure and short transition length, 7.2 mm. The mode converter shows excellent performances; the insertion loss of 0.12 dB at 15 GHz, and the return loss above 10 dB for the full Ku-band.

Open Source-Based Surgical Navigation for Fracture Reduction of Lower Limb (오픈소스 기반 수술항법장치의 하지 골절수술 응용검토)

  • Joung, Sanghyun;Park, Jaeyeong;Park, Chul-Woo;Oh, Chang-Wug;Park, Il Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.497-503
    • /
    • 2014
  • Minimally invasive intramedullary nail insertion or plate osteosynthesis has shown good results for the treatment of long bone fractures. However, directly seeing the fracture site is impossible; surgeons can only confirm bone fragments through a fluoroscopic imaging system. The narrow field of view of the equipment causes malalignment of the fracture reduction, and radiation exposure to medical staff is inevitable. This paper suggests two methods to solve these problems: surgical navigation using 3D models reconstructed from computed tomography (CT) images to show the real positions of bone fragments and estimating the rotational angle of proximal bone fragments from 2D fluoroscopic images. The suggested methods were implemented using open-source code or software and evaluated using a model bone. The registration error was about 2 mm with surgical navigation, and the rotation estimation software could discern differences of $2.5^{\circ}$ within a range of $15^{\circ}$ through a comparison with the image of a normal bone.

The Realization of Intensity-modulated Radiation Therapy Using the Liquid Shielding Material (액체 차폐물을 이용한 강도변조방사선치료의 구현)

  • 오영기;김진기;신교철;김기환;윤상모;김재철;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • We developed a new method that the radiation field shape and intensity could be controlled automatically with a insertion of the liquid shielding material box having a rotatable model imitated the 3-dimensional target volume within. The molded box filled with the mercury was mounted to the tray. A acrylic model imitated the 3-dimensional target volume was fixed into the center of the interior of the box. Although the gentry rotate, the acrylic model can be returned to the original direction of the target due to the action of the gravity. The film measurements at the gantry rotation angle 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$, respectively were shown that the radiation intensities were modulated properly and the field shapes were conformed to the target. We verified the dose distribution for our method with a cylindrical acrylic phantom inserted a film within. In the case of the 8-field irradiation, the 80% isodose line was enclosed the target shape properly. This results show the realization of a new intensity-modulated radiation therapy(IMRT).

  • PDF

Improvement of PWM Driving Control Characteristics for Low Power LED Security Light (저전력형 LED 보안등의 PWM형 구동제어 특성 개선)

  • Park, Hyung-Jun;Kim, Nag-Cheol;Kim, In-Su
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.368-374
    • /
    • 2017
  • In this Paper, we developed a low power type LED security light using LED lighting that substitutes a 220[V] commercial power source for a solar cell module instead of a halogen or a sodium lamp. in addition, a PWM type drive control circuit is designed to minimize the heat generation problem and the drive current of the LED drive controller. in developed system, The light efficiency measurement value is 93.6[lm/W], and a high precision temperature sensor is used inside the controller to control the heat generation of the LED lamp. In order to eliminate the high heat generated from the LED lamp, it is designed to disperse quickly into the atmosphere through the metal insertion type heat sink. The heat control range of LED lighting was $50-55[^{\circ}C]$. The luminous flux and the lighting speed of the LED security lamp were 0.5[s], and the beam diffusion angle of the LED lamp was about $110[^{\circ}C]$ by the light distribution curve based on the height of 6[m].

Development of a Belt Pick-up Type Two-row Sesame Reaper

  • Jun, Hyeon-Jong;Choi, Il-su;Kang, Tae-Gyoung;Kim, Young-Keun;Lee, Sang-Hee;Kim, Sung-Woo;Choi, Yong;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.281-287
    • /
    • 2016
  • Purpose: The purpose of this study is to develop a walking-type two-row sesame reaper, which can simultaneously perform the cutting and collecting of sesame plants and other crops like perilla and soybean. Methods: The factors involved in reaping sesame were determined experimentally in order to design a prototype of the sesame reaper. The prototype is made up of four parts for cutting, conveying, collecting, and running. The height of two disc-plate saw blades on the cutting part is adjusted by an adjusting wheel, and peripheral speed is adjusted in accordance with the running speed. The conveying belt of the conveying part can be tilted from $0^{\circ}$ to $90^{\circ}$. The collecting part extracts a predetermined amount of transferred sesame plants. The prototype was used to evaluate the performance at different working speeds, so that the work efficiency can be calculated. Results: The center of gravity of the sesame plants was 900 mm, measured from the end of the cut stem. The diameter of the disc-plate saw blade was determined to be 355 mm, peripheral speed was 20.4-32.7 m/s, and the picking height of the conveying belt for sesame was 130 mm. The performance of transfer and collection of the sesame, when the insertion angles were $60^{\circ}$ and $90^{\circ}$, proved to be excellent. However, when the angle was over $120^{\circ}$, the performance was only 75-80%. The performance was at 100% efficiency when the ratio between running speed and conveying belt speed of the prototype was 1:2, which seems to be the ideal ratio for the sesame reaper. Conclusions: A sesame reaper was developed, which can integrate the processes of cutting, conveying, and collecting, by investigating and considering various factors involved in the reaping process. The sesame reaper can reduce the costs for yielding and producing sesame due to its highly efficient performance.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Clinical Analysis of Video Assisted Thoracic Surgery for the Treatment of Thoracic Empyema (비디오 흉강경을 이용한 농흉수술의 임상분석)

  • Oh, Sang-Gi;Song, Sang-Yun;Yun, Chi-Hyeong;Na, Kook-Ju;Kong, Kang-Eun;Park, Song-Ran;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Background: Thoracic empyema remains a serious problem despite the availability of modern diagnostic methods and appropriate antibiotics. The condition presents in many different forms and stages that require different therapeutic options. Video-assisted thoracic surgery (VATS) has become increasingly popular for use in the treatment of empyema. Material and Method: From January 2005 to May 2009, VATS was performed in 36 patients with pleural empyema and for whom chest-tube drainage and antibiotic therapy had failed or the CT scan showed multiseptate disease. The perioperative clinical factors were analyzed for all the study patients. Result: All the patients underwent VATS, but it was necessary to convert to thoracotomy in one patient. The mean operation time was $90{\pm}38.5\;min$. For the operative evaluation, 11 patients were compatible with ATS stage III. The duration of chesttube insertion was $11.9{\pm}5.8$ (3~24) days. One patient did not improve and therefore this patient underwent additional open drainage. At discharge, costophrenic angle blunting was observed in 22 patients, pleural thickening was noted in 20 patients, both were noted in 17 patients and neither was noted in 11 patients. However, at follow-up, each of these changes was observed in 9, 7, 4 and 24 patients, respectively. All except one patient showed radiographic improvement. Conclusion: VATS is suitable for the treatment of early and fibrinopurulent thoracic empyema, and even in selected patients with stage III disease.

Reproducibility of Applicator Position with High dose rate brachytherapy in uterine cervical cancer (자궁경부암 환자의 근접치료시 재현성 평가)

  • Kim Jong-Hwa;Son Jung-Hae;Jung Chil;Kim Mi-Hwa
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.

  • PDF

Characteristics of New Microsporidia S80 Isolated from Silkworm, Bombyx mori L. in Korea (가잠(家蠶)으로부터 분리(分離)된 새로운 Microsporidia S80의 특성(特性))

  • Lim, Jong Sung;Cho, Sae Yun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.1
    • /
    • pp.67-83
    • /
    • 1983
  • The new microsporidia S80 isolated from, Bombyx mori L. in Korea showed ovoid in the morphology of the spores and the size were measured $2.9{\pm}0.28{\mu}$ in length and $1.7{\pm}0.29{\mu}$ width. No other microsporidian spore like this has not been so far isolated from Silkworm. The length of the polar filament extruded in hydrogen peroxide ($H_2O_2$) at $30^{\circ}C$ was $26{\mu}$ of a round cytoplasm on the top. The spores were partly stained with Giemsa, Safranin-O and Gram as the same staining properties as Nosema bombycis, Microsporidia K 79 and other microsporidian spores. The fine structures were observed under scanning eleceron microscope through ultrathin sectioning. The spore wall was composed of three layers ; the thin exospore of an electron dense rippled layer, the thick electron lucent endospore which was thinning considerably at the polar filament insertion point, and the inner limiting membrane. Polar cap present at the sporeapex, with a long polar filament of 12-13 coils, subtending angle of $60^{\circ}$ to spore axis, which is tubular made up of a multilayered and are a benes core, light ring structure enclosing the dance core, the dark ring structure enclosing the inner light ring structure and the other than and light ring structure bounded from cytoplasm. Lamellate polaroplast occupied the anterior part of the spore, and the two neclei with dense nucleoplasm bounded by a double nuclear envelope were cited in the slight downer middle portion of spore. From the characteristics of the shape, size and fine structures, it is certain to reason the Microsporidia S80 belong to the phylum Microspora, class Microspora, order Microsporida, order Microsporida. The shape of two nuclei cited seems to be genus Nosema, but in the classification for the suborder it should be defined wheather pansporoblasts be formed or not and for the genis especial attempts have been made to define the characters which distinguish the disporous genera in the life cycle. Survey through the infection of the bad cocoons during 1980 to 1982 in South Korea the areas contaminated with new microsporidia were revealed 5 provinces of Kyung-Gi, Kang-Won, Chung-Nam and Chun-Nam. Pathological effects inoculated per os at second instar larvae of silkworm, the LD 50 was $7.1{\times}10^7/ml$ as lower pathogenecity than that of Nosema bombycis Naegeli of $1.2{\times}10_7/ml$. While on the other hand the inoculation of the microsporidia at fourth instar larvae lowerd the whole cocoon weight and cocoon shell weight and significant at 1% level. The microsporidia S80 defined it can not be transmitted transovarially from the result of predictive and collective examination of 21 egg batches from the infected female moth.

  • PDF