• Title/Summary/Keyword: Insertion angle

Search Result 140, Processing Time 0.025 seconds

Optimization of Slanted and Chirp IDT Configurations for Realizing and Propagating Surface Acoustic Wave with Wide Bandwidth (광대역 표면탄성파 구현을 위한 slanted 및 chirp IDT의 최적화)

  • Lee, Tae-Yoon;Fu, Chen;Lee, Kee-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1730-1736
    • /
    • 2013
  • Slanted and chirp interdigital transducer(IDT) configurations were studied for generating the surface acoustic wave(SAW) with wide bandwidths on a piezoelectric substrate. These devices can be applied to manipulate optical path of light along the waveguide, ultimately used for optical switches and holographic image implementation. Prior to fabrication, the coupling of modes(COM) modeling and simulation were performed to extract optimal design parameters. The optimally designed wideband device showed wide bandwidth of 30MHz, low insertion loss of -25dB, and abrupt side suppression ratio (SSR). Several design conditions were determined during device implementation, such as slanted angle, aperture length, number of fingers, and central frequencies of IDTs. These factors were experimentally analyzed and described in details in this paper.

A Study on the Chucking of Ferrule using Cone-type Centers and Ball-type Centers in Co-Axial Grinding - Chucking Error Analysis (원추형 센터와 볼형 센터를 이용한 페룰 동축 연삭시 척킹에 관한 연구-척킹 오차 해석)

  • 김동길;박성준;김영태;이상조
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.40-49
    • /
    • 2003
  • Ferrule is widely used as fiber optic connecters. In fiber-optic communications. the shape accuracy such as coaxiality and cylindricity of ferrule affects insertion loss. When coaxial grinding of ferrule supported by two pin. pin alignment and chucking accuracy are very important. In this research, the kinematic behavior of the ferrule centers are investigated in the case where the ferrule is chucked with the cone-shaped center pins and bail centers, With homogeneous coordinate transformation and numerical analysis, the obtained results are as follows: In the case of cone-type center, the alignment errors between center pins alone do not affect the rotation accuracy of ferrule. The alignment errors between center holes cause sinusoidal displacement of ferrule. And the maximum displacement of ferrule centers is proportional to the center pin angle. In the case of ball-type center, the displacements of ferrule centers has similar pattern as cone-type center, and the alignment errors art proportional to ball diameters.

Variable Optical Attenuator Incorporating Dual Fiber Collimator and Bi-metal Actuator (이중 광 콜리메터와 바이메탈 엑추에이터를 이용한 가변 광감쇠기)

  • Kim, Kwang Taek;Kim, Duck Bong;Koh, Hanjun
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.28-31
    • /
    • 2018
  • In this paper, we have proposed and demonstrated a variable optical attenuator (VOA) incorporating a dual-fiber collimator and a bimetallic actuator. The optical attenuation between input and output single-mode fibers was tuned by tilting the angle of a reflection mirror fixed on the bimetal. The bimetal was heated or cooled by a thermoelectric cooler (TEC) and then moved the reflection mirror, due to bending and unreeling. The desired optical attenuation can be obtained through adjusting the electrical input into the TEC. The fabricated device showed 0.5 dB of insertion loss, 0.2 dB of maximum polarization-dependent loss, and 40 dB of dynamic range. The response time was measured to be about 5 s.

Patellofemoral Instability in Children: Imaging Findings and Therapeutic Approaches

  • Hee Kyung Kim;Shital Parikh
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.674-687
    • /
    • 2022
  • Patellofemoral instability (PFI) is common in pediatric knee injuries. PFI results from loss of balance in the dynamic relationship of the patella in the femoral trochlear groove. Patellar lateral dislocation, which is at the extreme of the PFI, results from medial stabilizer injury and leads to the patella hitting the lateral femoral condyle. Multiple contributing factors to PFI have been described, including anatomical variants and altered biomechanics. Femoral condyle dysplasia is a major risk factor for PFI. Medial stabilizer injury contributes to PFI by creating an imbalance in dynamic vectors of the patella. Increased Q angle, femoral anteversion, and lateral insertion of the patellar tendon are additional contributing factors that affect dynamic vectors on the patella. An imbalance in the dynamics results in patellofemoral malalignment, which can be recognized by the presence of patella alta, patellar lateral tilt, and lateral subluxation. Dynamic cross-sectional images are useful for in vivo tracking of the patella in patients with PFI. Therapeutic approaches aim to restore normal patellofemoral dynamics and prevent persistent PFI. In this article, the imaging findings of PFI, including risk factors and characteristic findings of acute lateral patellar dislocation, are reviewed. Non-surgical and surgical approaches to PFI in pediatric patients are discussed.

The facial tissue expansion to achieve the natural cervicomental angle (자연스러운 목턱각 성형을 위한 안면부 조직확장술)

  • Lee, Ki Eung;Koh, Jang Hyu;Seo, Dong Kook;Lee, Jong Wook;Choi, Jae ku;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.629-636
    • /
    • 2009
  • Purposes: Wide scars occurring on the lower face and neck are a source of both functional and esthetic problems. Consequently, we can use skin grafts, pedicled flaps, free flaps, and tissue expansion for the reconstruction of this area. Compared with other reconstruction techniques, tissue expansion is advantageous in that it enables the maintenance of a color and texture similar to that of the adjacent tissue. However, the conventional method of tissue expansion has been reported to lead to an unnatural cervicomental angle and to the deformity of adjacent structures. We have therefore made efforts to prevent these problems through the use of several operative procedures. Methods: Forty-one patients with lower facial and cervical scars underwent tissue expansion. The tissue expansion was performed using a rectangular-shaped Nagosil$^{(R)}$ tissue expansion device. On insertion of the tissue expander, the intermediate area of superficial fat layer was dissected and then the tissue expander was inserted to make a flap that was as thin as possible. In advancement of the flap, a capsule-formed by the tissue expander-was used for the interrupted fixed suture of the flap to the fascia of the platysma muscle of the neck. This procedure was performed multiple times and also performed between the flap and the periosteum of the mandible, such that the tension was removed during the suture of the flap margin. Finally, the patients were fitted with a Jobst$^{(R)}$ facial garment in order to stabilize the operation site at least twelve months. Results: The most prevalent location of the scar was the cheek (15 cases), followed by the chin in 14 cases and the neck in 12 cases. The mean size of scar was $55.7{\pm}39.4cm^2$. Conclusions: Using our procedures, we have experienced no significant deformities and have also achieved a more natural cervicomental angle in the patients.

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF

Denali Inferior Vena Cava Filter Retrieval: Complications and Success Rates (Denali 하대정맥 필터 제거: 합병증과 성공률)

  • Seoyun Choi;Kun Yung Kim;Hong Pil Hwang;Young Min Han
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.879-888
    • /
    • 2023
  • Purpose The present study was to evaluate the outcomes of Denali filter retrieval. Materials and Methods We retrospectively reviewed 143 patients who received Denali filter insertion from September 2015 to April 2020. Ninety-seven patients who required removal of the filters were include in this study. Filters were retrieved with either standard or advanced techniques. Venography before and after retrieval was obtained to evaluate technical success, complications and duration of filter insertion. Results All 97 filters were retrieved successfully without complications. Ninety-two (94.8%) were retrieved with standard technique and 5 filters (5.2%) required the advanced technique. There were two cases with a filter angle greater than 15 degrees. Inferior vena cava penetration was shown in 17 patients (17.5%) on venography but was not associated with contrast media extravasation after filter removal. Conclusion The Denali filter showed a high rate of successful retrieval without complications. This study adds value to previous studies and trials showing that the Denali filter is a reliable and safe filter that can potentially improve retrieval rates, with increasing use of this device.

A study on simplified procedure of enhanced designed implant drill (개선된 드릴 디자인을 적용한 간소화된 드릴링 과정에 관한 연구)

  • Yoon, Ji-Hoon;Jeon, Gye Rok;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.368-376
    • /
    • 2015
  • Purpose : The objective of this research was to develop a more simplified drilling procedure with an enhanced implant drill. Materials and Methods : The drill enhanced design factors enabled implantation of Dia. 5.0mm fixture with only 2 times drilling which is more simplified drilling procedure. The enhanced drill was designed with 2 flutes, 2-phase or 3-phase formed drill tip and 25 degrees of helix angle. The proposed drilling procedure (2 times) was compared with a general drilling process (4 times) in terms of temperature changes, cutting time and ISQ value. Results : The simplified drilling procedure indicated less heat than a conventional drilling procedure (p<0.05). The enhanced drill showed significantly shorter drilling time than a conventional drill (p<0.05). On the other hand, higher insertion torque and ISQ value were observed on the the suggested drilling procedure than the conventional drilling procedure (p<0.05). Conclusion : A simplified drilling procedure with the newly designed drill could provide higher effectiveness and safety of dental implant operations under properly controlled external conditions, such as irrigation and RPM of drilling.

1.55 μm polarization mode splitter utilizing two mode interference of Ti:LiNbO3 optical waveguides (1.55 μm Ti:LiNbO3 광도파로의 두 모드 간섭을 이용한 편광모드 분리기)

  • 김정희;정기조;정홍식;이한영
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.1
    • /
    • pp.32-37
    • /
    • 2002
  • Passive polarization mode splitters at λ= 1.55 ${\mu}{\textrm}{m}$ were designed and fabricated based on Ti:x-cut LiNbO$_3$ single-mode optical waveguide and two-mode interference theory. The splitting ratio with waveguide width 8 ${\mu}{\textrm}{m}$, branching angle 0.55$^{\circ}$ and interfering length 470 ${\mu}{\textrm}{m}$ showed 16.18 dB, 21.25 dB for TE and TM input polarization modes, respectively. Polarization cross-talk of -16.28 dB and -21.28 dB for TE and TM modes was achieved. Total insertion losses of 2.24 dB/cm (TE) and 2.41 dB/cm (TM) were also measured. The devices operated nearly wavelength independently over a range or 30 nm.

Ultrastructure of Spermatozoa in Pungtungia herzi (돌고기, Pungtungia herzi 정자의 미세구조)

  • 이영환;김구환
    • Development and Reproduction
    • /
    • v.2 no.2
    • /
    • pp.141-148
    • /
    • 1998
  • The fine structure of spermatozoa of Pungtungia herzi was examined with scanning and transmission electron microscopies. The spermatozoa of p. herzi are approximately 37.4 ${\mu}{\textrm}{m}$ in length and a relatively simple cell with a spherical nucleus, a short midpiece and a tail. The acrosome is not present as in most teleost fishes. The ultrastructure of spermatozoa represents typical characteristics of cyprinid spermatozoa including the lateral insertion of flagellum, the organization of centriolar complex in shallow nuclear fossa, and the occurrence and asymmetrical arrangement of mitochondria. In the nuclear envelope and mitochondrion, however there were some morphological differences for their ultrastructure. The nuclear envelope is severely undulated and the shallow nuclear fossa contains two centrioles which are at the angle of some 130$^{\circ}$ each other. The most significant feature can be observed with the mitochondrion; five or more mitochondria, which are shown in primary spermatocyte, fuse to form a single one in the mature spermatozoon. The mitochondrial aspect is different from that of other cyprinid spermatozoa, where their mitochondria have a conventional aspect and never fuse to form a mitochondrial derivative. In terms of sperm evolution the fused mitochondria are regarded as the apomorphic character in comparison with the separate mitochondria. The single mitochondrion is not reported in cyprinid spermatozoon except the case of Rhodeus.

  • PDF