Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

The Effect of Mean Brightness and Contrast of Digital Image on Detection of Watermark Noise (워터 마크 잡음 탐지에 미치는 디지털 영상의 밝기와 대비의 효과)

  • Kham Keetaek;Moon Ho-Seok;Yoo Hun-Woo;Chung Chan-Sup
    • Korean Journal of Cognitive Science
    • /
    • v.16 no.4
    • /
    • pp.305-322
    • /
    • 2005
  • Watermarking is a widely employed method tn protecting copyright of a digital image, the owner's unique image is embedded into the original image. Strengthened level of watermark insertion would help enhance its resilience in the process of extraction even from various distortions of transformation on the image size or resolution. However, its level, at the same time, should be moderated enough not to reach human visibility. Finding a balance between these two is crucial in watermarking. For the algorithm for watermarking, the predefined strength of a watermark, computed from the physical difference between the original and embedded images, is applied to all images uniformal. The mean brightness or contrast of the surrounding images, other than the absolute brightness of an object, could affect human sensitivity for object detection. In the present study, we examined whether the detectability for watermark noise might be attired by image statistics: mean brightness and contrast of the image. As the first step to examine their effect, we made rune fundamental images with varied brightness and control of the original image. For each fundamental image, detectability for watermark noise was measured. The results showed that the strength ot watermark node for detection increased as tile brightness and contrast of the fundamental image were increased. We have fitted the data to a regression line which can be used to estimate the strength of watermark of a given image with a certain brightness and contrast. Although we need to take other required factors into consideration in directly applying this formula to actual watermarking algorithm, an adaptive watermarking algorithm could be built on this formula with image statistics, such as brightness and contrast.

  • PDF

Design and Performance Analysis of a Parallel Cell-Based Filtering Scheme using Horizontally-Partitioned Technique (수평 분할 방식을 이용한 병렬 셀-기반 필터링 기법의 설계 및 성능 평가)

  • Chang, Jae-Woo;Kim, Young-Chang
    • The KIPS Transactions:PartD
    • /
    • v.10D no.3
    • /
    • pp.459-470
    • /
    • 2003
  • It is required to research on high-dimensional index structures for efficiently retrieving high-dimensional data because an attribute vector in data warehousing and a feature vector in multimedia database have a characteristic of high-dimensional data. For this, many high-dimensional index structures have been proposed, but they have so called ‘dimensional curse’ problem that retrieval performance is extremely decreased as the dimensionality is increased. To solve the problem, the cell-based filtering (CBF) scheme has been proposed. But the CBF scheme show a linear decreasing on performance as the dimensionality. To cope with the problem, it is necessary to make use of parallel processing techniques. In this paper, we propose a parallel CBF scheme which uses a horizontally-partitioned technique as declustering. In order to maximize the retrieval performance of the proposed parallel CBF scheme, we construct our parallel CBF scheme under a SN (Shared Nothing) cluster architecture. In addition, we present a data insertion algorithm, a rage query processing one, and a k-NN query processing one which are suitable for the SN cluster architecture. Finally, we show that our parallel CBF scheme achieves better retrieval performance in proportion to the number of servers in the SN cluster architecture, compared with the conventional CBF scheme.

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

  • Lee, Y.;Bok, J.D.;Lee, H.J.;Lee, H.G.;Kim, D.;Lee, I.;Kang, S.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.

An Embedded System Design of Collusion Attack Prevention for Multimedia Content Protection on Ubiquitous Network Environment (유비쿼터스 네트워크 환경의 멀티미디어 콘텐츠 보호를 위한 공모공격 방지 임베디드 시스템 설계)

  • Rhee, Kang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.1
    • /
    • pp.15-21
    • /
    • 2010
  • This paper proposes the multimedia fingerprinting code insertion algorithm when video content is distributed in P2P environment, and designs the collusion codebook SRP(Small RISC Processor) embedded system for the collusion attack prevention. In the implemented system, it is detecting the fingerprinting code inserted in the video content of the client user in which it requests an upload to the web server and in which if it is certified content then transmitted to the streaming server then the implemented system allowed to distribute in P2P network. On the contrary, if it detects the collusion code, than the implemented system blocks to transmit the video content to the streaming server and discontinues to distribute in P2P network. And also it traces the colluders who generate the collusion code and participates in the collusion attack. The collusion code of the averaging attack is generated with 10% of BIBD code v. Based on the generated collusion code, the codebook is designed. As a result, when the insert quantity of the fingerprinting code is 0.15% upper in bitplane 0~3 of the Y(luminance) element of I-frame at the video compression of ASF for a streaming service and MP4 for an offline offer of video content, the correlation coefficient of the inserted original code and the detected code is above 0.15. At the correlation coefficient is above 0.1 then the detection ratio of the collusion code is 38%, and is above 0.2 then the trace ratio of the colluder is 20%.

Design of Multilayer Radome with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 다층 구조 레이돔 설계)

  • Lee, Kyung-Won;Hong, Ic-Pyo;Park, Beom-Jun;Chung, Yeong-Chul;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.744-751
    • /
    • 2010
  • In this paper, the design of multilayer radome within, the insertion loss, -0.3 dB in X-band with PSO was carried out based on two cases. The first is that, deciding material constant of skin and core, each layer thickness of c-sandwich radome with PSO is found and the second is that, deciding material constant and thickness of the skins of both sides, the material constant and thickness of three layers between skins of both sides using PSO is decided. The performance of the designed radome almost agreed with the required performance. It was showed that the radome design applying PSO algorithm is easy and fast and the optimum radome is also designed in combination of the various parameters of radome. From these results, the radome having various performance can be designed except the tedious calculation and also be applied to various radome structure.

Signature-based Indexing Scheme for Similar Sub-Trajectory Retrieval of Moving Objects (이동 객체의 유사 부분궤적 검색을 위한 시그니쳐-기반 색인 기법)

  • Shim, Choon-Bo;Chang, Jae-Woo
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.247-258
    • /
    • 2004
  • Recently, there have been researches on storage and retrieval technique of moving objects, which are highly concerned by user in database application area such as video databases, spatio-temporal databases, and mobile databases. In this paper, we propose a new signature-based indexing scheme which supports similar sub-trajectory retrieval at well as good retrieval performance on moving objects trajectories. Our signature-based indexing scheme is classified into concatenated signature-based indexing scheme for similar sub-trajectory retrieval, entitled CISR scheme and superimposed signature-based indexing scheme for similar sub-trajectory retrieval, entitled SISR scheme according to generation method of trajectory signature based on trajectory data of moving object. Our indexing scheme can improve retrieval performance by reducing a large number of disk access on data file because it first scans all signatures and does filtering before accessing the data file. In addition, we can encourage retrieval efficiency by appling k-warping algorithm to measure the similarity between query trajectory and data trajectory. Final]y, we evaluate the performance on sequential scan method(SeqScan), CISR scheme, and SISR scheme in terms of data insertion time, retrieval time, and storage overhead. We show from our experimental results that both CISR scheme and SISR scheme are better than sequential scan in terms of retrieval performance and SISR scheme is especially superior to the CISR scheme.

A Study on the Implementation and Development of Image Processing Algorithms for Vibes Detection Equipment (정맥 검출 장비 구현 및 영상처리 알고리즘 개발에 대한 연구)

  • Jin-Hyoung, Jeong;Jae-Hyun, Jo;Jee-Hun, Jang;Sang-Sik, Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.6
    • /
    • pp.463-470
    • /
    • 2022
  • Intravenous injection is widely used for patient treatment, including injection drugs, fluids, parenteral nutrition, and blood products, and is the most frequently performed invasive treatment for inpatients, including blood collection, peripheral catheter insertion, and other IV therapy, and more than 1 billion cases per year. Intravenous injection is one of the difficult procedures performed only by experienced nurses who have been trained in intravenous injection, and failure can lead to thrombosis and hematoma or nerve damage to the vein. Nurses who frequently perform intravenous injections may also make mistakes because it is not easy to detect veins due to factors such as obesity, skin color, and age. Accordingly, studies on auxiliary equipment capable of visualizing the venous structure of the back of the hand or arm have been published to reduce mistakes during intravenous injection. This paper is about the development of venous detection equipment that visualizes venous structure during intravenous injection, and the optimal combination was selected by comparing the brightness of acquired images according to the combination of near-infrared (NIR) LED and Filter with different wavelength bands. In addition, an image processing algorithm was derived to threshehold and making blood vessel part to green through grayscale conversion, histogram equilzation, and sharpening filters for clarity of vein images obtained through the implemented venous detection experimental module.

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.