Browse > Article
http://dx.doi.org/10.5713/ajas.15.0353

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers  

Lee, Y. (Institute of Green-Bio Science and Technology, Seoul National University)
Bok, J.D. (Institute of Green-Bio Science and Technology, Seoul National University)
Lee, H.J. (Institute of Green-Bio Science and Technology, Seoul National University)
Lee, H.G. (Department of Animal Science and Technology, Konkuk University)
Kim, D. (Institute of Green-Bio Science and Technology, Seoul National University)
Lee, I. (Institute of Green-Bio Science and Technology, Seoul National University)
Kang, S.K. (Institute of Green-Bio Science and Technology, Seoul National University)
Choi, Y.J. (Institute of Green-Bio Science and Technology, Seoul National University)
Publication Information
Asian-Australasian Journal of Animal Sciences / v.29, no.2, 2016 , pp. 299-306 More about this Journal
Abstract
Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.
Keywords
Subcutaneous Temperature; Cattle; Fever Detection; Thermo-logger; Circadian Rhythm;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Adams, A. E., F. J. Olea-Popelka, and I. N. Roman-Muniz. 2013. Using temperature-sensing reticular boluses to aid in the detection of production disease in dairy cows. J. Dairy Sci. 96:1549-1555.   DOI
2 Bewley, J. M. 2006. Automatic temperature monitoring: What are the potential benefits? http://www.uky.edu/Ag/AnimalSciences/dairy/dairysystems/Automatic%20temperature%20monitoring%20potential%20benefits.pdf Accessed July 29, 2015.
3 Bewley, J. M., M. E. Einstein, M. W. Grott, and M. M. Schutz. 2008. Comparison of reticular and rectal core body temperatures in lactating dairy cows. J. Dairy Sci. 91:4661- 4672.   DOI
4 Bewley, J. M. and M. M. Schutz. 2010. Recent studies using a reticular bolus system for monitoring dairy cattle core body temperature. The First North American Conference on Precision Dairy Management. http://www.precisiondairy.com/ proceedings/s11bewley.pdf (Accessed July 29, 2015).
5 Bitman, J., A. Lefcourt, D. L. Wood, and B. Stroud. 1984. Circadian and ultradian temperature rhythms of lactating dairy cows. J. Dairy Sci. 67:1014-1023.   DOI
6 Brown, R. W., J. L. Thomas, H. M. Cook, J. L. Riley, and G. D. Booth. 1977. Effect of environmental temperature stress on intramammary infections of dairy cows and monitoring of body and intramammary temperatures by radiotelemetry. Am. J. Vet. Res. 38:181-187.
7 Carpenter, T. E., J. M. O'Brien, A. D. Hagerman, and B. A. McCarl. 2011. Epidemic and economic impacts of delayed detection of foot-and-mouth disease: A case study of a simulated outbreak in California. J. Vet. Diagn. Invest. 23:26-33.   DOI
8 Carroll, J. A., N. C. Burdick, C. C. Jr. Chase, S. W. Coleman, and D. E. Spiers. 2012. Influence of environmental temperature on the physiological, endocrine, and immune responses in livestock exposed to a provocative immune challenge. Domest. Anim. Endocrinol. 43:146-153.   DOI
9 Cilia, J., D. C. Piper, N. Upton, and J. J. Hagan. 1998. A comparison of rectal and subcutaneous body temperature measurement in the common marmoset. J. Pharmacol. Toxicol. Methods. 40:21-26.   DOI
10 Dalal, S. and D. S. Zhukovsky. 2006. Pathophysiology and management of fever. J. Support. Oncol. 4:9-16.
11 McLaws, M., C. Ribble, W. Martin, and J. Wilesmith. 2009. Factors associated with the early detection of foot-and-mouth disease during the 2001 epidemic in the United Kingdom. Can. Vet. J. 50:53-60.
12 Goodwin, S. 1998. Comparison of body temperatures of goats, horses, and sheep measured with a tympanic infrared thermometer, an implantable microchip transponder, and a rectal thermometer. Contemp. Top. Lab. Anim. Sci. 37:51-55.
13 Hutu, I., F. Ionescu, A. Cimponeriu, and M. Chilintan. 2009. RFID technology used for identification and temperature monitoring of cattle. Lucrari Stiintifice Medicina Veterinara. 42:44-50.
14 Joo, Y. S., S. H. An, O. K. Kim, J. Lubroth, and J. H. Sur. 2002. Foot-and-mouth disease eradication efforts in the Republic of Korea. Can. J. Vet. Res. 66:122-124.
15 Olsen, S. J., Y. Laosiritaworn, S. Pattanasin, P. Prapasiri, and S. F. Dowell. 2005. Poultry-handling practices during avian influenza outbreak, Thailand. Emerg. Infect. Dis. 11:1601- 1603.   DOI
16 Park, J. H., K. N. Lee, Y. J. Ko, S. M. Kim, H. S. Lee, Y. K. Shin, H. J. Sohn, J. Y. Park, J. Y. Yeh, Y. H. Lee, M. J. Kim, Y. S. Joo, H. Yoon, S. S. Yoon, I. S. Cho, and B. Kim. 2013. Control of foot-and-mouth disease during 2010-2011 epidemic, South Korea. Emerg. Infect. Dis. 19:655-659.   DOI
17 Prendiville, D. J., J. Lowe, B. Earley, C. Spahr, and P. Kettlewell. 2002. Radiotelemetry systems for measuring body temperature. Grange Research Centre. Beef Production Series No. 57:1-14.
18 TekVet Health Monitoring System by TekVet Technologies Co. An external ear canal temperature monitoring system. http://www.tekvet.com/low/index.html Accessed July 29, 2015.
19 TempVerified by FeverTags LLC. An external ear canal temperature monitoring system. http://www.fevertags.com/ Accessed July 29, 2015.
20 TempTrack by DVM Systems LLC. Rumen bolus type temperature monitoring system. http://www.dvmsystems.com/ beta7-1/ Accessed July 29, 2015.
21 Thermo-transponder (IPPT-100 or -300) by Bio Medic Data System. http://www.bmds.com/products/transponders/iptt-300 Accessed July 29, 2015.
22 Won, Y. J., Y. H. Kim, Y. Lim, Y. K. Moon, and S. O. Lim. 2012. Development of livestock traceability system based on implantable RFID sensor tag with MFAN. J. Korea. Inform. Commun. Soc. 37C:1318-1327.