• 제목/요약/키워드: Insertion 4p

검색결과 347건 처리시간 0.026초

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

  • Lee Jong-Hyuk;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.314-324
    • /
    • 2006
  • Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study about correlation between indirect values and degree of osseointegration. Purpose. The aims of this study were to evaluate the coefficient of correlation between indirect measurement and direct measurement under different healing time, and assessment of effect of initial insertion torque to the implant stability. Material and Methods. 20 rabbits received 3 implants on each side of tibia. Three kinds of implants (machined surface implant, Sandblasted with Large grit and Acid etched implant, Resorbable Blast Media treated implant) were used. During the surgery implant insertion torque were measured with $Osseocare^{TM}$. After the 1, 4, 8, 12 weeks of healing time, animals were sacrificed and stability values (Implant Stability Quotient with $Osstell^{TM}$, removal torque with torque gauge) were measured. Results. The Bone quality of rabbit tibia was classified into 2 groups according to the insertion torque. Resonance frequency analysis (ISQ) and removal torque showed positive correlation until $4^{th}$ week (r=0.555, p=0.040). After $8^{th}$ week (r=0.011, p=0.970) the correlation became weak and it turned negative at $12^{th}$ week (r=-0.074, p=0.801). Insertion torque and ISQ showed changing correlation upon the healing time ($1^{st}$ week: r=0.301, p=0.033, $4^{th}$ week: r=-0.429, p=0.018, $8^{th}$ week: r=0.032, p=0.865, $12^{th}$ week: r=-0.398, p=0.029). Insertion torque and removal torque has positive correlation but it was not statistically significant ($1^{st}$ week: r=0.410, p=0.129, $4^{th}$ week: r=0.156, p=0.578, $8^{th}$ week: r=0.236, p=0.398, $12^{th}$ week: r=0.260, p=0.350). Conclusion. In this study, bone quality may affect the degree of osseointegration positively during healing time and correlation between ISQ and degree of osseointegration can be different according to the healing time and bone quality.

The change of rotational freedom following different insertion torques in three implant systems with implant driver

  • Kwon, Joo-Hyun;Han, Chong-Hyun;Kim, Sun-Jai;Chang, Jae-Seung
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.37-40
    • /
    • 2009
  • STATEMENT OF PROBLEM. Implant drivers are getting popular in clinical dentistry. Unlike to implant systems with external hex connection, implant drivers directly engage the implant/abutment interface. The deformation of the implant/abutment interface can be introduced while placing an implant with its implant driver in clinical situations. PURPOSE. This study evaluated the change of rotational freedom between an implant and its abutment after application of different insertion torques. MATERIAL AND METHODS. Three kinds of internal connection implants were utilized for the current study($4.5{\times}12\;mm$ Xive, $4.3{\times}11.5\;mm$ Inplant Magicgrip, $4.3{\times}12\;mm$ Implantium MF). An EstheticBase, a 2-piece top, a Dual abutment was used for its corresponding implant system. The rotational freedom between an implant and its abutment were measured before and after applying 45, 100 Ncm insertion torque. Repeated measures ANOVA was used for statistical analysis. RESULTS. Under 45 Ncm insertion torque, the rotational freedom between an implant and its abutment was significantly increased in Xive(P = .003). However, no significant change was noted in Inplant Magicgrip and Implantium MF. Under 100 Ncm torque, both in Xive(P = .0005) and Implatium MF(P = .03) resulted in significantly increased rotational freedom between the implant and its abutment. DISCUSSION. The design of the implant/implant driver interface effectively prevented the deformation of implant/abutment interface. Little change was noted in the rotational freedom between an implant and its abutment, even though the insertion torque was far beyond clinical application. CONCLUSIONS. The implant/abutment joint of internally connecting implants were quite stable under insertion torque in clinical situation.

Maxillary sinus haziness and facial swelling following suction drainage in the maxilla after orthognathic surgery

  • Lee, Jung-Soo;Kim, Moon-Key;Kang, Sang-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.33.1-33.8
    • /
    • 2020
  • Background: We investigated the efficacy of a maxillary Jackson-Pratt (J-P) suction drain for preventing maxillary sinus hematoma and facial swelling after maxillary Le Fort I osteotomy (LF1). Methods: We retrospectively evaluated 66 patients who underwent LF1 at a single institution. Of these, 41 had a J-P suction tube inserted in the mandible and maxilla (maxillary insertion), and 25 had a J-P drain inserted in the mandible only (no maxillary insertion). Facial CT was obtained before and 4 days after surgery. We compared mean midfacial swelling and maxillary sinus haziness by t test and examined correlations between bleeding amount and body mass index (BMI). Results: For the maxillary-insertion group, the ratio of total maxillary sinus volume to haziness (57.5 ± 24.2%) was significantly lower than in the group without maxillary drain insertion (65.5% ± 20.3; P = .043). This latter group, however, did not have a significantly greater midfacial soft tissue volume (7575 mm3) than the maxillary-insertion group (7250 mm3; P = .728). BMI did not correlate significantly with bleeding amount or facial swelling. Conclusions: Suction drainage in the maxilla reduced maxillary sinus haziness after orthognathic surgery but did not significantly reduce midfacial swelling.

임플랜트 지대주 나사와 드라이버의 설계가 보철물 장착 및 철거 시간에 미치는 영향에 관한 연구 (THE EFFECTS OF THE DESIGN OF ABUTMENT SCREW DRIVER ON THE AMOUNT OF TIME FOR INSERTION OF SCREW DRIVER INTO ABUTMENT SCREW HEAD)

  • 김성균
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.258-263
    • /
    • 2005
  • Statement of problem. Implant screw loosening has been remained a problem in implant prosthodontics. The time needed to insert screw driver into abutment screw head should be shortened for the purpose of decreasing the chair time. Purpose. The purpose of this study was to investigate the effects of the design of abutment screw driver on the amount of time for insertion of screw driver into abutment screw head. Material and methods. Hexagonal and rectangular types of abutment screw drivers were used. The original abutment screw drivers were modified by grinding acute angle of the screw driver tip (modified drivers). Group 1 : hexagonal type abutment screw and original driver Group 2 : hexagonal type abutment screw and modified driver Group 3 : rectangular type abutment screw and original driver Group 4 : rectangular type abutment screw and modified driver UCLA lab analogues were located in acrylic resin block. The angulations of them were 0 and 20 degrees. The times needed for insertion were measured. Group 1 and 3 were used as controls. Results. 1. Group 2 showed shorter insertion time than group 1, regardless of implant angulations (p<.05). 2. Group 4 showed shorter insertion time than group 3, regardless of implant angulations (p<.05). Conclusion. Modified abutment screw drivers required less amount of time to insert screw driver into abutment screw head. Modification of abutment screw driver was beneficial.

A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables

  • Lee, Su-Young;Piao, Chunmei;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Kim, Tae-Hyung;Kim, Myung-Joo;Kwon, Ho-Beom;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권4호
    • /
    • pp.148-153
    • /
    • 2010
  • PURPOSE. The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS. Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS. The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P ${\geq}$ .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION. Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.

3가지 성문위기도기(Supraglottic airway device)의 삽관 용이성과 삽관시간 비교 - 마네킨을 이용한 연구- (Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices - A manikin study -)

  • 김상태;강보라;탁양주
    • 한국응급구조학회지
    • /
    • 제16권2호
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel($1.00{\pm}0.00$) and SLIPA($1.05{\pm}0.27$) than cLMA($1.16{\pm}0.41$, p<.05). The shortest time to insertion was recorded for I-gel($10.5{\pm}3.0sec$), followed by the SLIPA($12.9{\pm}4.5sec$) and cLMA($19.6{\pm}4.1sec$, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.

Use of Lidocaine Patch for Percutaneous Endoscopic Lumbar Discectomy

  • Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • 제24권2호
    • /
    • pp.74-80
    • /
    • 2011
  • Background: Lidocaine patch (L5P) has demonstrated short-term efficacy in treating both acute surgical pain and chronic neuropathic pain with tolerable side effects. Percutaneous endoscopic lumbar discectomy (PELD) is the mainstay of minimally invasive spine surgery (MISS). Sufficient analgesia during PELD surgery makes the patient consider it real MISS. This study was performed to evaluate the efficacy and adverse effects of lidocaine patch in patients who underwent PELD under local anesthesia. Methods: L5P (L group) or placebo (P group) was randomly applied on the skin of the back covering the anticipated path of the working channel before 1 hour of surgery in 100 patients who underwent a single level PELD at L4-L5. Efficacy of the lidocaine patch was assessed by patient's numeric rating scale (NRS) of pain at each stage during the surgery and by a 5-scale grading of the satisfaction with the anesthesia of the operator and patients after surgery. Results: Mean NRS scores at the stages of needle insertion, skin incision, serial dilation and insertion of working channel, and subcutaneous suture were significantly lower in the L group than the P group. Postoperative operator's and patients' satisfaction scores were also significantly higher in L group than in the P group. There were subtle adverse effects in both groups. Conclusions: L5P provided better pain relief during PELD, especially at the stage of needle insertion, skin incision, serial dilation and insertion of working channel, and subcutaneous suture. It also provided higher patient and operator postoperative satisfaction, with only subtle adverse effects.

EFFECT OF IMPLANT DESIGNS ON INSERTION TORQUE AND IMPLANT STABILITY QUOTIENT (ISQ) VALUE

  • Piao Chun-Mei;Heo Seong-Joo;Koak Jai-Young;Kim Seong-Kyun;Han Chong-Hyun;Fang Xian-Hao
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.325-332
    • /
    • 2006
  • Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant stability and osseiointegratation are considered highly desirable. Purpose. The purpose of this study was to evaluate the ISQ value and the insertion torque of the 3 different implant system, then to evaluate whether there was a correlation between ISQ value and insertion torque; and to determine whether implant design has an influence on either insertion torque or ISQ value. Material and method. The experiment was composed of 3 groups: depending on the implant fixture design. Group1 was Branemark type parallel implant in $3.75{\times}7mm$. Group2 was Oneplant type straight implant in $4.3{\times}8.5mm$. Group3 was Oneplant type tapered implant in $4.3{\times}8.5mm$. Depending on the density of the bone, 2 types of bone were used in this experiment. Type I bone represented for cortical bone, type II bone represented for cancellous bone. With the insertion of the implant in type I and type II bone, the insertion torque was measured, then the ISQ value was evaluated, and then the correlation between insertion torque and ISQ value was analyzed Result and conclusion. Within the limitations of this study, the following conclusions were drawn. 1. Within the 3 different implants, the insertion torque value and ISQ value were higher in type I bone, when compared with type II bone.(p<0.05) 2. In type I and type II bone, Oneplant type tapered implant has the highest value in insertion torque.(p<0.05) 3. In type I and type II bone, there was no difference in ISQ values among the 3 types of implant. (p>0.05) 4. Significant linear correlation was found in $Br{\aa}nemark$ type parallel implant: $3.75{\times}7mm$ in type II bone.

Power spectrum density analysis for the influence of complete denture on the brain function of edentulous patients - pilot study

  • Perumal, Praveen;Chander, Gopi Naveen;Anitha, Kuttae Viswanathan;Reddy, Jetti Ramesh;Muthukumar, Balasubramanium
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.187-193
    • /
    • 2016
  • PURPOSE. This pilot study was to find the influence of complete denture on the brain activity and cognitive function of edentulous patients measured through Electroencephalogram (EEG) signals. MATERIALS AND METHODS. The study recruited 20 patients aged from 50 to 60 years requiring complete dentures with inclusion and exclusion criteria. The brain function and cognitive function were analyzed with a mental state questionnaire and a 15-minute analysis of power spectral density of EEG alpha waves. The analysis included edentulous phase and post denture insertion adaptive phase, each done before and after chewing. The results obtained were statistically evaluated. RESULTS. Power Spectral Density (PSD) values increased from edentulous phase to post denture insertion adaption phase. The data were grouped as edentulous phase before chewing (EEG p1-0.0064), edentulous phase after chewing (EEG p2-0.0073), post denture insertion adaptive phase before chewing (EEG p3-0.0077), and post denture insertion adaptive phase after chewing (EEG p4-0.0096). The acquired values were statistically analyzed using paired t-test, which showed statistically significant results (P<.05). CONCLUSION. This pilot study showed functional improvement in brain function of edentulous patients with complete dentures rehabilitation.

근관내(根管內) 근관충전제(根管充塡劑)의 유입성(流入性)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE FLOW OF CANAL SEALER BY MEANS OF LENTULO)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제1권1호
    • /
    • pp.34-38
    • /
    • 1975
  • Artificial canals were prepared by means of engine reamer on the slab which was made of clear acrylic resin. The shape of this canal is similar to the natural canal, the size is almost same as Kerr File No. 70, and the length is about 20mm. Sealer, Zine oxide eugenol mixture was prepared as matched to spatula test. Lentulo filler was inserted as deep as middle portion and apical one-third portion of the canal and the dental engine was driven in the speed of 1,000 and 3,000 r.p.m. in 30 seconds and 60 seconds with feeding of the sealer. The author measured the excess flow of the canal sealer from Lentulo end. Following are the results obtained from this study. 1. Lentulo insertion at the middle portion 1,000 r.p.m. in 30 seconds case: 0.21mm Same as above in 60 seconds: 0.20mm 2. Lentulo insertion at apical-thirds. 1,000 r.p.m. in 30 seconds: 0.22mm. Same as above in 60 seconds: 0.20mm. 3. Lentulo insertion at middle portion. 3,000 r.p.m. in 30 seconds: 0.14mm Same as above in 60 seconds: 0.25mm. 4. Lentulo insertion at apical-thirds, 3,000 r.p.m. in 30 seconds: 0.11mm Same as above in 60 seconds: 0.27mm.

  • PDF