• Title/Summary/Keyword: Inserting length

Search Result 93, Processing Time 0.026 seconds

Manufacturing and characterization of tufted preform with complex shape

  • Gnaba, Imen;Wang, Peng;Legrand, Xavier;Soulat, Damien
    • Advances in aircraft and spacecraft science
    • /
    • v.6 no.2
    • /
    • pp.105-116
    • /
    • 2019
  • An alternative to the multilayered preforming is to use structures reinforced through-the-thickness in order to manufacture thicker and more complex pieces. Stitching technology is developed to bind dry reinforcements together or to strengthen composites in thickness performance by inserting structural yarns. Tufting process represents the simplest one-sided sewing technology and it is specifically designed for dry preform/liquid composite molding process route. Currently, the tufting technology is getting more and more interest due to its simplest and efficient process where it involves the insertion of binder threads via a single needle through the fabric. This technique of reinforcement through-the-thickness requires only one access to the preform which makes it suitable for three-dimensional structures and complex shaped textile composites. This paper aims to improve the understanding of the mechanical performance of tufted structures. An experimental study was developed, which included tensile and bending behaviours of tufted and un-tufted preforms, in order to evaluate the effect of tufting on the mechanical performance of dry preforms. The influence of the process parameters (tufting density, loop length, tufting yarns${\ldots}$) on the mechanical performance ofthe final structure is also highlighted.

A Design of Expandable IC Card Operating System (확정성 있는 IC 카드 운영체제의 설계)

  • 박철한
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.9 no.2
    • /
    • pp.49-60
    • /
    • 1999
  • IC 카드의 하드웨어적인 제약으로 대부분의 IC 카드는 대칭키 알고리즘을 사용하고 있지만 IC 카드 하드웨어 제조 기술의 발전으로 앞으로는 보안성이 우수한 비대 칭키 알고리즘이 많이 사용될 것이다. 그리고 IC 카드의 가장 큰 제약적 중 하나는 메모리 용량의 한계이다. 따라서 보안상 안전하면서도 메모리를 적게 사용하는 IC 카드 운영체제의 구현을 중요한 문제이다. 그래서 본 논문에서는 다양한 종류의 키 알고리즘을 수용할 수 있는 키 파일 탐색 기법을 제안하였다. 또한 데이터 파일 헤더에 잠금 필드를 삽입하여 보안성을 향상시켰으며 메모리 사용량을 줄일 수 있도록 데이터 파일 헤더만을 이용한 파일 탐색 기법과 자유 공간 탐색 기법을 제안하였다. Because of the evolution of IC card hardware fabrication technologies IC card will be able to accept asymmetric key encryption algorithm in the future. One of the most restrictive points of IC card is memory capacity. Therefore it is an important problem to design a secure IC card operating system using memory in small. In this paper we proposed a key file search mechanism using a key length field inserted in a key file header structure. The key file search mechanism makes IC card execute any key-based encryption algorithm. In addition we proposed inserting a lock field in data file header structure. The lock field intensifies the security of a data file. Finally we proposed a data file search mechanism and free space search mechanism using only data file header. The file system using these mechanisms spends smaller memory than that using a file description table and record of unallocated space.

Air leakage due to the cuff hanging on the vocal cords during nasotracheal intubation: a case report

  • Seung-Hwa Ryoo;Myong-Hwan Karm;Se-Ung Park;Hyun Jeong Kim;Kwang-Suk Seo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.39-43
    • /
    • 2023
  • Nasotracheal intubation is commonly performed under general anesthesia in oral and maxillofacial surgery. For the convenience of surgery, nasal Ring-Adair-Elwyn (RAE) tubes are mainly used. Because the nasal RAE tubes were bent in an "L" shape, the insertion depth was limited. Particularly, it is necessary to accurately determine the appropriate depth of the RAE tubes in children. Several types of nasal RAE tubes are used in the medical market, which vary in material and length. We performed endotracheal intubation using a nasal RAE tube for double-jaw surgery, but air leakage persisted even when the air pressure in the cuff was increased. When checked with a laryngoscope, it was confirmed that the tube was pushed out, and the cuff was caught on the vocal cords, causing air leakage. Since inserting the tube deeply did not solve the problem, replacing it with a nasal RAE tube (PolarTM, Preformed Tracheal Tube, Smith Medical, Inc., USA) did not cause air leakage; thus, we reported this case.

The Design of the Ultra-Wideband Slot Antenna by Using a Semi-Circular Extension (반원 확장을 이용한 초광대역 슬롯 안테나 설계)

  • Lee Jung-Nam;Lee Hyo-Kyoung;Jang Hwa-Yeol;Park Jong-Kweon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.941-948
    • /
    • 2005
  • In this paper, we have proposed a Ultra-Wideband slot notch antenna by using a semi-circular extension. The proposed antenna cover the entire UWB band(3.1${\~}$10.6 GHz) and notch out the IEEE 802.1la frequency band(5.15${\~}$5.825 GHz) by inserting a $\lambda$/4 length slot into the patch. A prototype antenna was fabricated on FR-4( ${\epsilon}_r$ =4.4, substrate thickness=0.8 mm) and measured for VSWR characteristics. The measured notched frequency variations versus frequency for different slot length. The path loss and group delay were measured. The proposed antenna also show a good gain flatness(1.9 dBi) except the IEEE 802.1la frequency band.

Analysis of a T-Shaped UWB Printed Monopole Antenna Using Surface Currents (표면 전류 분포를 이용한 T자형 UWB 평면형 모노폴 안테나 해석)

  • Lee Dong-Hyun;Park Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.9 s.100
    • /
    • pp.883-892
    • /
    • 2005
  • We propose a T-shaped UWB printed monopole antenna and investigate the effect of the surface currents of the radiator and ground plane. The measured impedance bandwidth of the antenna covers the range of 3.1 to 11 GHz for a VSWR$\le$2, which satisfies the requirement of the UWB operation. From the analysis of the surface currents, the proposed antenna can be treated as two asymmetric dipoles with the included angle of 90 degrees which lie along z-direction symmetrically. It is observed that the effect of the surface currents on the radiation patterns is similar to that of the corresponding dipole. The length and width of the found plane correspond the radius and length of the dipole respectively. This approach is also valid to general printed monopole antennas. Finally, we included an antenna example having resonance at a lower frequency by tapering the edges of the ground plane and another example having a bandstop characteristic by inserting an inverted-U slot on the radiator, and explain those antennas using the surface currents.

Slit Folded Type Microstrip Antenna for Omnidirectional E-plane and H-plane (전방향성 E & H면 슬릿 Folded형 마이크로스트립 패치 안테나)

  • 김종래;우종명;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.956-963
    • /
    • 2002
  • A linearly polarized folded type and H-shape slit folded type microstrip patch antenna at GPS(center frequency:1.575 GHz) were designed and fabricated by folding a conventional single $\lambda_{g}/2(\lambda_{g}:wavelength)$ rectangular patch a half along the length direction at the center of patch and inserting ground plane in the middle. As a result, two types of omnidirectional radiation patterns for E-plane (for zx-plane) in the direction of the length of patch and H-plane (for xy-plane) have been acquired. The experimental results show that the average gains of folded type and slit folded type for omnidirectional E-plane and H-plane are -1.5 dBd (-2.4 dBd) and -3.27 dBd(-2.5 dBd). Slit folded type microstrip patch antenna was more miniaturized than folded type microstrip patch antenna by 27.5 %. In case of slit folded type antenna, average gains of omnidirectional radiation pattern for E & H-plane are almost same.

The Analysis of Pattern Components of Brassiere and Study on Its Making (브래지어의 패턴 구성요소 분석 및 제작법 연구)

  • Lee, So-Young
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.15 no.2
    • /
    • pp.15-26
    • /
    • 2013
  • The purpose of this study is to offer basic data for designing and making of brassiere with the consideration of the physiological nature of man. Each of 3/4-cup wired upward-support-type Mold Bra of 75 size with basic pad made at three representative domestic companies (A, B and C Company) was selected for analysis of pattern and components. The following is the result of this study. 1. That Company A's bra had the highest cup, relatively narrow width, the widest front-center and the highest front center at front pad. That of Company B had relatively short wing over the base and much difference at the height of cup depending on the presence of wire. That of Company C had low and wide cup, the widest bust span and the front center width, the front center height of front pad, the base length of front pad and the length of wings were observed to be of the figures between those of Company A and B. 2. The Bra of Company A had the biggest front center angle of $6^{\circ}$, while that of Company C had the biggest wing angle of $18^{\circ}$. The Bra of Company B showed the biggest difference of patterns depending on the presence of wire. Those of Company A and C showed very similar shape when wire was inserted. 3. The order of making brassiere is following: making of exterior mold cup${\rightarrow}$ sewing exterior cup and circumference of mold${\rightarrow}$ sewing base and wings${\rightarrow}$ sewing binding tape to base${\rightarrow}$ sewing cup and main pad${\rightarrow}$ sewing binding tape to upper sides and upper part of wings${\rightarrow}$ sewing wire-tape to interior base of cup${\rightarrow}$ inserting of wire inside wire-tape${\rightarrow}$ sewing hook & eye on the back of wings${\rightarrow}$ sewing shoulder string.

  • PDF

Design of Compact Stepped Open Slot Antenna for UWB Applications (UWB 응용을 위한 소형 계단형 개방 슬롯 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, a design method for a compact stepped open slot antenna for an operation in the UWB band is studied. The proposed antenna is miniaturized by inserting L-shaped slots on the ground plane of the stepped open slot antenna through the creation of a resonance in the low frequency, and a strip director is appended to the antenna in order to increase the gain in the middle and high frequency regions. The effects of varying the length of the L-shaped slots, the distance between the director and the slot antenna, and the director length on input reflection coefficient and realized gain characteristics of the proposed antenna are analyzed. The optimized antenna with the size of $30mm{\times}30mm$ is fabricated on an FR4 substrate, and the experiment results show that the antenna has a frequency band of 3.02-11.04 GHz for a VSWR < 2, which assures the operation in the UWB band.

Comparative evaluation of flexural strength and modulus of denture base resin with mesh and stick type glass fiber reinforcement (망사 및 스틱 형태의 유리섬유 보강재를 삽입한 의치상용 레진의 굴곡강도 및 굴곡계수 비교 평가)

  • Kim, Dong-Yeon;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.91-98
    • /
    • 2020
  • Purpose: This study is to compare the flexural strength and modulus by inserting a mesh and stick type fiberglass reinforcement into resin specimens. Methods: Wax specimens (length 64 mm, width 39 mm, thickness 5 mm) are prepared according to ISO 20795-1:2013. Mesh type and stick type glass fiber reinforcements were prepared. The prepared wax specimens were used plaster and flask for investment. The flask was separated and the wax was removed. The heat curing resin was injected into the flask, and then a mesh type and stick type fiberglass reinforcement were inserted. The prepared resin specimen was cut into three equal parts (length 64 mm, width 10 mm, thickness 3.3 mm). The mesh type glass fiber reinforcement (MT group) and the stick type glass fiber reinforcement (ST group) were classified into two groups. The prepared specimen was measured using a universal testing machine (UTM). The data were analyzed by Mann-Whitney U test, and the significance level was set to 0.05. Results: In the flexural strength, the ST group was higher than the MT group, and there was a significant difference between the two groups (p<0.05). In the flexural modulus, the ST group was higher than the MT group, and there was a significant difference between the two groups (p<0.05). Conclusion: The stick-type glass fiber inreased the flexural strength than the mesh-type glass fiber reinforcement.

The Study for standardized Method of the Retention-Enema; For a Method of Experimental Study (보류관장의 표준화된 방법을 위한 고찰을 통한 제언; 실험연구방법에 대하여)

  • Song, Eun-Young;Lee, Eui-Ju;Yoo, Jung-Hee;Lee, Jun-Hee;Koh, Byung-Hee;Bu, Yong-Min;Park, Jae-Woo;Kim, Hyo-Jin;Chai, Kwang-Min
    • The Journal of Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Objectives: This study was to propose a standardized method of retention enema by extracting elements associated with published experimental methods of retention enema. Methods: 1) Literature search (1) Data sources: Retrieval was made, using 'Enema' or 'Retention Enema' as search words in Medline, Cochrane library, KISS, RISS, and KDSL DB. (2) Study selection: Two authors excluded irrelevant papers and chose qualified abstracts from the rest of the papers. The chosen studies were reviewed fully by the authors so that they could screen the significant papers based on the exclusion criteria. (3) Data extraction: Data on the total number of subjects, the target disease, the animal species, the type, quality, length, and diameter of catheter, the insertion length of catheter, the sample, the sample volume, the process of retention enema and the number of retention enemas performed were extracted from the selected studies. 2) Performing preliminary experiments about the elements associated with experimental methods of retention enema. Results & Conclusions: The standardized experimental method is as follows: animal: 280-320g SD rat 1) inserting a rectal tube of 8 Fr that measures 8 cm into the animal's anus, 2) injecting herbal medicines at the volume of 6ml and 3) holding them for 10 minutes.