• 제목/요약/키워드: Inserted type

검색결과 521건 처리시간 0.03초

종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성 (Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture)

  • 이기수;강찬;황득수;노창균;이기영
    • 대한족부족관절학회지
    • /
    • 제19권1호
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

V/UHF대역 소형다이폴 원형배열 능동안테나 설계 (Design of V/UHF band Small Dipole Circular Array Active Antenna)

  • 고지환;이철수;김강욱;조영기
    • 한국정보통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.6-16
    • /
    • 2009
  • V/UHF대 방향 탐지(DF)용에 적용하기 위하여 9개의 다이폴 소자로 구성된 원형배열 안테나를 연구하였다. 배열 안테나의 전체 크기를 줄이기 위하여 소자는 top-hat 다이폴 형태를 이용하였다. 20-1,300Mhz인 매우 넓은 주파수 범위에서 동작하기 위하여 각 다이폴 소자의 팔(arm)의 중간에 pin diode를 삽입하였다. 이런 형태의 다이폴을 이용하므로 pin diode의 on/off에 따라 다이폴의 실효 길이를 증감할 수 있다. 능동 배열 안테나는 평형 푸시풀 증폭기와 직접 연결되게 설계하므로 수신 감도를 개선할 뿐만 아니라 발룬 역할을 하였다. 그리고 능동 배열 안테나를 설계 및 제작하였고, 측정 결과를 계산 결과와 비교하여 제시하였다.

Survival of 352 titanium implants placed in 181 patients: a 4-year multicenter field study

  • Shin, Seung-Il;Yun, Jeong-Ho;Kim, Sung-Geun;Park, Byoungkyou;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • 제44권1호
    • /
    • pp.8-12
    • /
    • 2014
  • Purpose: The aim of this retrospective chart review was to evaluate the four-year survival rate of a titanium implant system. Methods: A total of 352 sand-blasted, thermally acid-etched titanium implants were inserted into 181 partially or completely edentulous patients. Their cumulative survival rate was evaluated retrospectively. Associated factors, such as the implant distribution and treatment type were included in the evaluation. Results: The implants were equally distributed between the maxilla (52.3%) and the mandible (47.7%). 48 implants (13.6%) were placed in the anterior region and 304 implants (86.4%) in the posterior region. The majority of the implants were inserted into bone of type II and III quality (89.8%) and volume (quantity B and C, 87.2%). Most of the implants (70.7%) were restored as single crowns; 28.7% supported a bridge construction and 0.6% a full denture. Only one implant failed, resulting in a four-year cumulative survival rate of 99.7%. Conclusions: The implant system showed an excellent four-year survival rate. It proved to be a safe and predictable means for restoration of the dentition in partially or completely edentulous patients.

평면형 다이폴 안테나를 이용한 UHF RFID 태그 안테나 특성 (The Characteristics for UHF RFID Tag Antenna Using Planar Dipole Antenna)

  • 김영달;이영훈;권원현
    • 한국전자파학회논문지
    • /
    • 제16권2호
    • /
    • pp.204-210
    • /
    • 2005
  • 본 논문에서는 RFID 칩 실장이 용이한 접지면이 첨가된 평면형 미엔더 형태의 평면형 다이폴 안테나를 이용 하여 UHF 대역에서 동작하는 RFID 태그용 안테나를 제안하였다. 태그의 크기를 명함 크기로 구현하기 위해서 안테나는 meander 형태로 구현하였으며, 안테나의 특성 개선을 위하여 T-정합법을 사용하였고, RFID 칩 실장이 용이한 구조를 구현하기 위해서 접지면을 첨가하였다. 논문에서 제안한 방법을 통하여 구현한 안테나의 크기는 $100\times60\;mm^2$이고, 유전체는 FR4를 사용하였다. 실험 결과 방사 패턴은 다이폴 안테나와 같이 전 방향(omnidirectional) 특성이며, 중심 주파수는 427 MHz, -10 dB 반사 손실 대역폭은 8 MHz, 최대 반사 손실은 21 dB이다. 따라서 본 논문에서 제안한 방법을 이용하여 RFID 칩 실장이 용이한 RFID 태그용 안테나를 구현할 수 있다.

전통건축에 사용된 자귀의 형태 변화에 대한 고찰 (A Study on the Change of Shape of "Jagui" (Adze) Used in Korean Traditional Architecture)

  • 임채현
    • 건축역사연구
    • /
    • 제20권3호
    • /
    • pp.23-38
    • /
    • 2011
  • The Axes and Adzes are the oldest tools since the beginning of human history which is used to cut the tree and make part of architecture such as boards, square timber etc. Nowadays, these old woodworking tools especially "Jagui(자귀)" (adze) has been almost disappeared at the working site of residential and cultural properties. It is necessary to study Korean traditional woodworking tools to keep Korean traditional skill and technology. It has been reviewed the change of shape of "Jagui(자귀)" (adze) from before Samhan (삼한) period to Joseon Dynasty through excavated relics and paintings and summarize as follows: Based on excavation relics of Dahori, both plate type blade and pocket type blade are used for "Tokki(도끼)" (axe) and "Jagui(자귀)" (adze). The excavated "Jagui(자귀)" (adze) from Jeongbaikri 356 tomb, near Pyongyang is prototype of "Jagui(자귀)" (adze) used nowdays which has almost same shape as well as the insert method of blade and handle. The auxiliary handle is inserted to blade and the main handle is inserted to the auxiliary handle which is different from the method of Chinese and Japanese "Jagui(자귀)" (adze). The length of handle of "Jagui(자귀)" (adze) until late Joseon Dynasty is short by which we assume it is used for a sitting position as hand held Jagui and from that time long handle has been introduced for a standing position which is called "Sunjagui(선자귀)". "Jagui(자귀)" (adze) has been used since the beginning of human history but it is almost disappeared at the most of woodworking site which is the crisis of Korean traditional architecture and we have to do something to keep it.

Influence of size and insertion depth of irrigation needle on debris extrusion and sealer penetration

  • Uzunoglu-Ozyurek, Emel;Karaaslan, Hakan;Turker, Sevinc Aktemur;Ozcelik, Bahar
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.2.1-2.10
    • /
    • 2018
  • Objectives: To determine the effect of size and insertion depth of irrigation needle on the amount of apical extruded debris and the amount of penetration depth of sealer using a confocal laser scanning microscope (CLSM). Materials and Methods: Twenty maxillary premolars were assigned to 2 groups (n = 10), according to the size of needle tip, 28 G or 30 G. Buccal roots of samples were irrigated with respective needle type inserted 1 mm short of the working length (WL), while palatal roots were irrigated with respective needle type inserted 3 mm short of the WL. Prepared teeth were removed from the pre-weighed Eppendorf tubes. Canals were filled with F3 gutta-percha cone and rhodamine B dye-labeled AH 26 sealer. Teeth were transversally sectioned at 1 and 3 mm levels from the apex and observed under a CLSM. Eppendorf tubes were incubated to evaporate the irrigant and were weighed again. The difference between pre- and post-weights was calculated, and statistical evaluation was performed. Results: Inserting needles closer to the apex and using needles with wider diameters were associated with significantly more debris extrusion (p < 0.05). The position of needles and level of sections had statistically significant effects on sealer penetration depth (p < 0.05 for both). Conclusions: Following preparation, inserting narrower needles compatible with the final apical diameter of the prepared root canal at 3 mm short of WL during final irrigation might prevent debris extrusion and improve sealer penetration in the apical third.

하악 대구치의 II형 근심 근관에서 치근단 부위의 만곡도 조사 (An evaluation of canal curvature at the apical one third in type II mesial canals of mandibular molars)

  • 윤혜림;이동균;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.104-109
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the buccolingual curvature at the apical one third in type II mesial canals of mandibular molars using the radius and angle of curvature. Materials and Methods: Total 100 mandibular molars were selected. Following an endodontic access in the teeth, their distal roots were removed. #15 H- or K-files (Dentsply Maillefer) were inserted into the mesiobuccal and mesiolingual canals of the teeth. Radiographs of the teeth were taken for the proximal view. Among them, type II canals were selected and divided into two subgroups, IIa and IIb. In type IIa, two separate canals merged into one canal before reaching the apex and in type IIb, two separate canals merged into one canal within the apical foramen. The radius and angle of curvature of specimens were examined. Results: In type II, mean radius of curvature in mesiolingual and mesiobuccal canals were 2.82 mm and 3.58 mm, respectively. The radius of the curvature of mesiolingual canals were significantly smaller than that of mesiobuccal canals in type II, and especially in type IIa. However, there were no statistically significant differences in radius of curvature between mesiobuccal and mesiolingual canals in type IIb and there were no significant differences in angle of curvature between type IIa and IIb. Conclusion: In this study, type II mesial canals of mandibular molars showed severe curvature in the proximal view. Especially, mesiolingual canals of type IIa had more abrupt curvature than mesiobuccal canals at the apical one third.

테트라싸이클린 및 테트라싸이클린-구연산 혼합젤로 처리한 치근면의 항 미생물 활성 변화에 관한 연구;In Vivo Study (Antimicrobial Activities of Root Surfaces Treated with Tetracycline-containing gel and a Mixture of tetracycline and citric acid-containing gel;in vivo study)

  • 정희선;한수부;남석우;심창구;계승범
    • Journal of Periodontal and Implant Science
    • /
    • 제27권1호
    • /
    • pp.79-90
    • /
    • 1997
  • The purpose of this study was to evaluate the substantivity of experimentally developed gel type tetracycline HCl and a mixture of tetracycline-citric acid gel, and compare to those of solution type tetracycline HCl. 11 extracted anterior teeth were subjected to this study. After scaling and root planing teeth were randomly divided into 3 treatments groups : group 1; 3 teeth were irrigated with tetracycline HCl(50mg/ml) solution , group 2; tetracycline gel (5%) was inserted in the periodontal pockets of 3 teeth, group 3; a mixture of tetracycline and citric acid gel was inserted in the pockets of 3 teeth. And 2 teeth treated in 0.9 % sterile saline served as controls. After 5-minute exposure, each tooth immediately extracted and incubated at room temperature for 22 days in tris-buffered saline as a desorption media. The total volume of TBS was removed and replaced with fresh TBS, at 24-h intervals. Removed desorption media transferred to a sterile vial and stored at -70 oC. This procedure was repeated every 24 h throughout the 22-day desorption period. Using Porphyromonas gingivalis as an indicator organism, a microtiter assay was used to evaluate antimicrobial activity desorbed from the teeth. 1. 50mg/ml tetracycline HCl solution exhibited the longest antimicrobial activity. Compared to saline treated group, it showed significant difference on the day 1 and day 2 desorption period. 2. The ODs of 5% tetracycline gel and a mixture of tetracycline-citric acid gel were significantly different during the first 24 hour only. 3. There was no statistically significant difference after the day 3 between the groups.(p<0.05). Despite our expectation a mixture of tetracycline-citric acid gel did not show longer antimicrobial activities than those of tetracycline gel, and the solution type exhibited the longest activities. Because the gel type agents may stay in the subgingival environment longer than the solution, if the teeth were not extracted immediately after the delivery of the agent, the result could be different. hus this result suggests the possibilities of practical use of these kind of gel type agents.

  • PDF

Forced Resonant Type Cutoff Cavity-Backed Aperture Antennas Loaded with a Single External Reactance

  • Kim Ki-Chai;Hirasawa Kazuhiro
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.105-111
    • /
    • 2005
  • This paper presents the basic characteristics of a cutoff cavity-backed aperture antenna with a feed post and a parasitic post inserted parallel to the aperture. It is shown that this type of antenna forcibly resonates the cutoff cavity by adding a single external reactance to the parasitic post. The Galerkin's method of moments is used to analyze integral equations for the unknown electric current on each post and the aperture electric field on the aperture. The value of an external reactance for forced resonance is analytically obtained by deriving a determining equation. Also the current distribution on each post, aperture electric field distributions, and the radiation patterns are discussed. The theoretical analysis is verified by the measured return loss and radiation patterns.

Measurement and Comparison of Iron Loss in Bonded- and Embossed-Type Segmented Stator Cores for IPMSM

  • Jeong, Kwangyoung;Zhang, Dianhai;Kwon, Jaehoon;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2013-2018
    • /
    • 2014
  • According to the manufacturing process of the laminated stator core for an inserted permanent magnet synchronous motor (IPMSM), the iron loss may be different. It is because the mechanical stress imposed to electrical steel sheet is strongly dependent on the manufacturing process. This paper proposes a new iron loss measurement algorithm which utilizes the induced voltage of a search coil and exciting current. The method is effective even when the distribution of magnetic flux density is not uniform along the magnetic flux path as well as uniform. The developed iron loss measurement system is applied to bonded- and embossed-type segmented stator cores of an IPMSM, and the iron losses are quantitatively compared.