• Title/Summary/Keyword: Inserted site

Search Result 247, Processing Time 0.029 seconds

A Experimental Investigation on the PD Characteristics depending on the various Artificial Voids In Epoxy Insulator (에폭시 절연체의 보이드 크기에 따른 부분방전 특성연구)

  • Choi, C.K.;Lee, J.S.;Kim, J,T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1853-1855
    • /
    • 2000
  • An experimental investigation has been performed in order to understand the $\Phi$-q-n characteristics related to the PD taking place from the various size of artificial defects inserted in epoxy insulation. In this purpose, PD has been detected simultaneously by two different methods such as commercialized PD detector(TE571) and our detection system using self designed CT type sensor. Under the presence of void in epoxy insulation, PD has been initiated at the voltages between 16kV and 20kV which are much lower than the dielectric strength of epoxy insulation (130kV/mm$\sim$l50kV/mm). And also it is revealed that $\Phi$-q-n characteristics have been observed to be dependent upon the size of the artificial defects. Throughout this work, the on site applicability of the self designed Sensor has also been proved by comparing the results with those from the commercialized PD detector. And more one, considerable basic data regarding the insulation, diagnosis could be provided to understand the presence of the voids possibly inserted into the epoxy insulation system of the power apparatus.

  • PDF

Proximal Interphalangeal Joint (PIPJ) Arthrodesis for Treating PIPJ Osteoarthritis in a Horse

  • Seo, Jeeyoon;Park, Joon-Young;Lee, Minhyun;Cho, Young-Jae;Kim, Byung Hyun;Seo, Jong-Pil
    • Journal of Veterinary Clinics
    • /
    • v.36 no.5
    • /
    • pp.292-295
    • /
    • 2019
  • A 2-year-old, 440 kg, thoroughbred gelding showed a lameness grade of 3 out of 5, as well as swelling and heating on the proximal interphalangeal joint (PIPJ). Periarticular new bones due to the arthritis were observed on performing radiography and ultrasonography. PIPJ arthrodesis was performed under general anesthesia. With the PIPJ open, the articular cartilage was removed by using curette, chisel, and mallet. Arthrodesis was performed with a PIP plate and two additional transarticular cortex screws inserted in lag fashion. A cast was placed over the limb distal from the proximal metatarsal bone. At 6 months after surgery, complete union of the PIPJ was confirmed by radiography, and the incision site was well closed. Based on the outcome, a PIP plate with two additional transarticular cortex screws inserted in lag fashion is recommended as a method for treating osteoarthritis of the PIPJ in horses.

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

The Availability of Gore-Tex® Tube as Nerve Conduit at the Peripheral Nerve Defect (말초신경 결손시 신경도관으로서 Gore-Tex® 도관의 유용성)

  • Lee, Ki Ho;Oh, Sang Ha;Lee, Seung Ryul;Kang, Nak Heon
    • Archives of Plastic Surgery
    • /
    • v.32 no.5
    • /
    • pp.613-618
    • /
    • 2005
  • When a large peripheral nerve defect occurs, an autologous nerve graft is the most ideal method of recinstruction. But an autologous nerve graft has many limitations due to donor site morbidities. Many previous focused on finding the ideal nerve conduit. Among them, $Gore-Tex^{(R)}$ has several advantages over other conduits. It can be manipulated to a suitable size, does not collapse easily, and it is a semi- permeable material that contain pores. A round shaped nerve can be newly formed because of its smooth inner surface. The purpose of this study was to evaluate the availability of $Gore-Tex^{(R)}$ tube as a nerve conduit at the peripheral nerve defect in the rat sciatic nerve. The 10 mm nerve gap was made in each group. A $Gore-Tex^{(R)}$ tube filled with skeletal muscle was inserted and autologous nerve graft was harvested, respectively. In the experimental group, we placed a 0.5 mm thickness, $30{\mu}m$ pored, 1.8 mm in diameter and 14 mm length tube with skeletal muscle inserted inside. In the control group, the nerve gap was inserted with a rat sciatic nerve. We estimated the results electrophysiologically and histologically to 16 weeks postoperatively. Results in the nerve conduction velocity, total myelinated axon count, myelin sheath thickness and mean nerve fiber diameter, the experimental group was substantially lower than that of the control group, but the statistic difference was not significant (p<0.05). The morphology was very similar in both groups, microscopically. From the above results, We conclude that $Gore-Tex^{(R)}$ qualifies as an ideal nerve conduit. It is suggested that $Gore-Tex^{(R)}$ tube filled with skeletal muscle may, substitute for an autologous nerve graft.

A Peripherally Inserted Central Catheter is a Safe and Reliable Alternative to Short-Term Central Venous Catheter for the Treatment of Trauma Patients

  • Ryu, Dong Yeon;Lee, Sang Bong;Kim, Gil Whan;Kim, Jae Hun
    • Journal of Trauma and Injury
    • /
    • v.32 no.3
    • /
    • pp.150-156
    • /
    • 2019
  • Purpose: To determine whether a peripherally inserted central catheter (PICC) meets the goals of a low infection rate and long-term use in trauma patients. Methods: From January 2016 to June 2018, the medical records of patients who underwent central venous catheterization at a level I trauma center were retrospectively reviewed. Data collected included age, sex, injury severity score, site of catheterization, place of catheterization (intensive care unit [ICU], emergency department, or general ward), type of catheter, length of hospital stay during catheterization, types of cultured bacteria, time to development of central line-associated bloodstream infection (CLABSI), and complications. Results: During the study period, 333 central vein catheters (CVC) were inserted with a total of 2,626 catheter-days and 97 PICCs were placed with a total of 2,227 catheter-days. The CLABSI rate was significantly lower in the PICC group when the analysis was limited to patients for whom the catheter was changed for the first time in the ICU after CVC insertion in the ER with similar indication and catheter insertion times (18.6 vs. 10.3/1,000 catheter-days, respectively, p<0.05). The median duration of catheter use was significantly longer in the PICC group than in the CVC group (16 vs. 6 days, respectively, p<0.05). Conclusions: The study results showed that the duration of catheter use was longer and the infection rate were lower in the PICC group than in the CVC group, suggesting that PICC is a safe and reliable alternative to conventional CVC.

Stability of structural steel tubular props: An experimental, analytical, and theoretical investigation

  • Zaid A. Al-Sadoon;Samer Barakat;Farid Abed;Aroob Al Ateyat
    • Steel and Composite Structures
    • /
    • v.49 no.2
    • /
    • pp.143-159
    • /
    • 2023
  • Recently, the design of scaffolding systems has garnered considerable attention due to the increasing number of scaffold collapses. These incidents arise from the underestimation of imposed loads and the site-specific conditions that restrict the application of lateral restraints in scaffold assemblies. The present study is committed to augmenting the buckling resistance of vertical support members, obviating the need for supplementary lateral restraints. To achieve this objective, experimental and computational analyses were performed to assess the axial load buckling capacity of steel props, composed of two hollow steel pipes that slide into each other for a certain length. Three full-scale steel props with various geometric properties were tested to construct and validate the analytical models. The total unsupported length of the steel props is 6 m, while three pins were installed to tighten the outer and inner pipes in the distance they overlapped. Finite Element (FE) modeling is carried out for the three steel props, and the developed models were verified using the experimental results. Also, theoretical analysis is utilized to verify the FE analysis. Using the FE-verified models, a parametric study is conducted to evaluate the effect of different inserted pipe lengths on the steel props' axial load capacity and lateral displacement. Based on the results, the typical failure mode for the studied steel props is global elastic buckling. Also, the prop's elastic buckling strength is sensitive to the inserted length of the smaller pipe. A threshold of minimum inserted length is one-third of the total length, after which the buckling strength increases. The present study offers a prop with enhanced buckling resistance and introduces an equation for calculating an equivalent effective length factor (k), which can be seamlessly incorporated into Euler's buckling equation, thereby facilitating the determination of the buckling capacity of the enhanced props and providing a pragmatic engineering solution.

Development of a Food-Grade Integration Vector for Heterologous Gene Expression and Protein Secretion in Lactococcus lactis

  • Jeong, Do-Won;Lee, Jong-Hoon;Kim, Kyoung-Heon;Lee, Hyong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.11
    • /
    • pp.1799-1808
    • /
    • 2006
  • A food-grade integration vector based on site-specific recombination was constructed. The 5.7-kb vector, pIMA20, contained an integrase gene and a phage attachment site originating from bacteriophage A2, with the ${\alpha}$-galactosidase gene from Lactobacillus plantarum KCTC 3104 as a selection marker. pIMA20 was also equipped with a controllable promoter of nisA ($P_{nisA}$) and a signal peptide-encoding sequence of usp45 ($SP_{usp45}$) for the production and secretion of foreign proteins. pIMA20 and its derivatives mediated site-specific integration into the attB-like site on the Lactococcus lactis NZ9800 chromosome. The vector-integrated recombinant lactococci were easily detected by the appearance of blue colonies on a medium containing $X-{\alpha}-gal$ and also by their ability to grow on a medium containing melibiose as the sole carbon source. Recombinant lactococci maintained these traits in the absence of selection pressure during 100 generations. The ${\alpha}-amylase$ gene from Bacillus licheniformis, lacking a signal peptide-encoding. sequence, was inserted downstream of $P_{nisA}\;and\;SP_{usp45}$ in pIMA20, and the plasmid was integrated into the L. lactis chromosome. ${\alpha}-Amylase$ was successfully produced and secreted by the recombinant L. lactis, controlled by the addition and concentration of nisin.

New Approach to the Care of Suction Drain Insertion Site by Using Occlusive Transparent Film Dressing (투명필름 밀폐 드레싱을 이용한 새로운 배액관 관리법)

  • Kwon, Soon Hong;Oh, Deuk Young;Choi, Youn Suk;Lee, Paik Kwon;Rhie, Jong Won;Han, Ki Taik;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.131-134
    • /
    • 2006
  • The closed suction drain is commonly inserted after various surgical procedures. It has an important role to prevent possible hematoma or seroma that can cause postoperative wound problems. But there is still no consensus on managing the insertion site of suction drain after operation. Suture-tie fixation of drain to skin and classical Y shape gauze dressing is a usually accepted method, but it has many limitations. We introduce a new approach to the care for the insertion site of suction drain by using occlusive transparent film dressing, $IV3000^{(R)}$(Smith & Nephew, London, UK). By using transparent film, insertion site of drain can be easily checked without removal of dressing. Because it can reduce the tension of suture-tie fixation, it helps to prevent skin injury. Furthermore, occlusive film dressing can block air leakage from insertion site of drain, and the water-proof character of film allows patients to take a shower without dressing change. This new method is more convenient, more efficient, and less harmful to skin than classic one.

A Fundermental Study on Stabilization in Municipal Waste Landfill Site (도시폐기물 매립지의 안정화에 관한 기초연구)

  • 김은호;김순호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • The investigation was carried out to analyze the generation and the composition of landfill gas generated from inserted pipe wells into the underground by boring operation and also study the undecomposed waste characteristics by open-cut test at S. waste landfill site in Pusan city. Pilot test was conducted for stabilization. The experimental results from this study were summerized as follows. ; Since COD matter was easuer decomposed than COD matter for continuously biological stabilization in underground, it seemed that BOD and CO $D_{Mn}$ were in the range of 854~4,813mg/$\ell$ and 1,156~6,977mg/$\ell$ and their ratio were generally as high as 0.55~0.74. As C $H_4$ compositions of generated gas were measured in the range of 37.36~60.1%, we could know that C $H_4$ gas was actively generated. Organic matters by open-cut test averaged 13.4~16.6% at each landfill layer, and considering rate of combustible compositions(36.2~66.5%) for landfilling wastes, they have been actively decomposed. The measured and theoretical values of generated gas in waste landfill site were almost similar to C $H_4$ 50.0% and 53.4%, $CO_2$ 39.63% and 45.24%, and after 0.5$^{\circ}C$ with heavy depth and long landfill period. From the results of pilot test for stabilization, after 180 days organic matters were actively decomposed beyond 2.2 times in facultative aerobic lystimeter(B) to exsiting anaerobic lysimeter(A). Therefore, it seemed that landfill site was of benefical to the conversion of facultative aerobic for stabilization.

  • PDF

Cloning of the Hepatitis B Surface Antigen Containing Pre-surface Antigen Region and Poly(A) Addition Site (Pre-surface antigen 지역과 poly(A) addition site가 포함된 B형 간염 표면항원 유전자의 재조합)

  • Kim, Sang-Hae;Kim, Yong-Sok;Park, Mee-Young;Park, Hyune-Mo
    • The Korean Journal of Zoology
    • /
    • v.28 no.3
    • /
    • pp.166-178
    • /
    • 1985
  • In order to express hepatitis B surface antigen $(HB_sAg)$ containing pre-surface antigen region in mammalian calls, 2.7 kb DNA fragment containing pre-surface region-$HB_sAg$ gene poly(A) addition site of HBV genome was cloned into simian virus 40(SV 40) based chimeric vector pSVOB. 2.7 kb DNA fragment was derived from pHBVD 107 containing tandem copies of the HBV genome in a head-to-tail arrangement by Bgl II digestion. Construction of the vector pSVOE involved the incorporation of SV40 sequences spanning the viral origin of replication and 72 bp repeats (enhancer) into a pBR 322 derivative lacking sequences which inhibit replication in mammalian cells. Bam HI linker was inserted at the Pvu II site in the proximity of SV40 late promoter of pSVOE and named as pSVOB. To construct the recombinant plasmid pSVBS, pHBVD 107 was digested with Bgl II to isolate 2.7kb DNA fragment and the fragment was ligated into the Bam HI site of pSVOB by ligation. Preliminary result showed that the recombinant plasmid pSVBS produced $HB_sAg$ in the monkey cell producing large T antigen (COS cell).

  • PDF