• Title/Summary/Keyword: Input Amplitude

Search Result 483, Processing Time 0.024 seconds

Performance of Receive Diversity UWB Systems with Pulse Amplitude and Position Modulation

  • Kim, Sang-Choon
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.498-501
    • /
    • 2010
  • In this paper, we extend ultra-wideband (UWB) single input single output (SISO) systems with a hybrid pulse amplitude and position modulation (PAPM) to single input multiple output (SIMO) systems using receive antenna diversity. The performance of a rake receive diversity combining scheme for UWB SIMO systems with a PAPM is examined in a log-normal multipath fading channel and also compared with that of a time-switched transmit diversity (TSTD) multiple input single output (MISO) system. It is seen that as the number of receive antennas increases, the receive diversity combining system improves the error performance. It is shown that the TSTD UWB MISO systems offer the performance equivalent to the receive diversity combining scheme for SIMO systems.

Effect of an initial displacement on a nano-guiding system (나노 가이드 시스템에서 초기 변위의 영향에 관한 연구)

  • Lee, Dong-Yeon;Lee, Moo-Yeon;Gweon, Dae-Gab;Park, June-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1396-1403
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response oi the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54Hz).

  • PDF

Effect of an Initial Displacement on a Nano-guiding System (나노 가이드 시스템에서 초기 변위의 영향에 관한 연구)

  • Lee, Moo-Yeon;Gweon, Dae-Gab;Lee, Dong-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.346-354
    • /
    • 2006
  • This study shows that the system performance of a positioning system composed of a piezoelectric actuator-driven flexure guide depends largely on the preload applied on the flexure guide and the driving input amplitude. We used a flexure guided system that had an original resonant frequency of 54 Hz. Our experiment showed that we could increase the driving bandwidth above the original resonant frequency, for a case involving a large preload and a small input amplitude. Results show that there is a specific 'separation frequency' where the response of the moving mass of the flexure system decouples from the response of the piezoelectric actuator, and this specific separation frequency can be selected by a proper choice of the preload and the input amplitude. To find the separation frequency, sine sweep tests were performed. To confirm the increased system bandwidth frequency, open-loop sine tracking experiments were performed. Test results show that the system responds very well up to 130 Hz frequency higher than the original natural frequency (54 Hz).

A Discrete-Amplitude Pulse Width Modulation for a High-Efficiency Linear Power Amplifier

  • Jeon, Young-Sang;Nam, Sang-Wook
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.679-688
    • /
    • 2011
  • A new discrete-amplitude pulse width modulation (DAPWM) scheme for a high-efficiency linear power amplifier is proposed. A radio frequency (RF) input signal is divided into an envelope and a phase modulated carrier. The low-frequency envelope is modulated so that it can be represented by a pulse whose area is proportional to its amplitude. The modulated pulse has at least two different pulse amplitude levels in order that the duty ratios of the pulse are kept large for small input. Then, an RF pulse train is generated by mixing the modulated envelope with the phase modulated carrier. The RF pulse train is amplified by a switching-mode power amplifier, and the original RF input signal is restored by a band pass filter. Because duty ratios of the RF pulse train are kept large in spite of a small input envelope, the DAPWM technique can reduce loss from harmonic components. Furthermore, it reduces filtering efforts required to suppress harmonic components. Simulations show that the overall efficiency of the pulsed power amplifier with DAPWM is about 60.3% for a mobile WiMax signal. This is approximately a 73% increase compared to a pulsed power amplifier with PWM.

Logic gate implementation of constant amplitude coded CS/CDMA transmitter (정포락선 부호화된 CS-CDMA 송신기의 논리 게이트를 이용한 구현)

  • 김성필;류형직;김명진;오종갑
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.281-284
    • /
    • 2003
  • Multi-code CDMA is an appropriate scheme for transmitting high rate data. However, dynamic range of the signal is large, and power amplifier with good linearity is required. Code select CDMA (CS/CDMA) is a variation of multi-code CDMA scheme that ensures constant amplitude transmission. In CS/CDMA input data selects multiple orthogonal codes, and sum of these selected codes are MPSK modulated to convert multi-level symbol into different carrier phases. CS/CDMA system employs level clipping to limit the number of levels at the output symbol to avoid hish density of signal constellation. In our previous work we showed that by encoding input data of CS/CDMA amplitude of the output symbol can be made constant. With this coding scheme, level clipping is not necessary and the output signal can be BPSK modulated for transmission. In this paper we show that the constant amplitude coded(CA-) CS/CDMA transmitter can be implemented using only logic gates, and the hardware complexity is very low. In the proposed transmitter architecture there is no apparent redundant encoder block which plays a major role in the constant amplitude coded CS/CDMA.

  • PDF

Comparison Between Performance of a Sound-Triggered Measurement and an Amplitude-Triggered Measurement in Shaking Table Tests (진동대를 이용한 모바일 진동 계측 기기의 사운드 트리거 계측과 진폭 트리거 계측 성능 비교)

  • Mapungwana, S.T.;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.117-126
    • /
    • 2019
  • Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking-table tests. It was seen that sound-triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.

Experimental Investigation on the Pressure-Drop Instabilities in Boiling Channel (비등유로의 압력강하 불안정성에 대한 실험적 고찰)

  • Kim, B.J.;Shin, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.179-186
    • /
    • 1993
  • The characteristics of pressure-drop oscillations(PDO) in boiling channel are studied experimentally. The effects of initial and boundary conditions on PDO are investigated in terms of oscillation period and amplitude. The period and amplitude of PDO are increased with the increase in the compressible volume in surge tank and heat input. However the amplitude of PDO is decreased with fluid temperature under low subcooling condition. Higher initial insurge flowrate resulted in almost invariant oscillation period but lower amplitude. At higher heat input the oscillation of heater wall temperature is significant, whose period is the same as that of pressure-drop instability.

  • PDF

Implementation of the Self-tuning Control Algorithm with an Input- amplitude Constraint (제어입력 크기가 제한되는 자기동조 제어알고리즘의 구현에 관한 연구)

  • 장효환;정회범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2153-2161
    • /
    • 1993
  • Self-tuning control algorithms for an input-amplitude constrained system are developed and implemented. Magnitude of control input for small motors is generally restricted to narrow bound due to actuator saturation. The gain-adjusted control algorithm and the bounded-gain control algorithm proposed in this study yield smoother control input variations within the magnitude constraints comparing with the existing Clarke's suboptimal control algorithm. In the gain-adjusted control algorithm, the feedforward gain is adjusted using maximum gain, while in the bounded-gain control algorithm, the feedforward gain is bounded using weighting factor. For the DC servo motor control, the system performances of the proposed algorithms are compared with those of the existing algorithm by computer simulation and experiment. It is shown that the input variations of the proposed algorithms are smoother as compared with the existing algorithm.

Oversampled Sigma-Delta A/D Converters Designed by Bilinear Transform (쌍선형 변환에 의한 과표본화율의 시그마-델타 A/D 변환율)

  • Park, Chong-Yeun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.808-815
    • /
    • 1990
  • This paper treats with the design method for the single loop oversampled Sigma-Delta A/D converter with one delay and the digital integrator. Such an integrator was kgenerated by means of the bilinear transform of the analog integrator. The frequency spectrums of the quantizer and the decimator output signal are evaluated by FFT respectively. With the performance evaluation system, the values of SNR are obtained versus the input sinusoidal signal amplitude, frequency, the oversampling ratio, the DC-input level, the loop gain and the limitting value of the integrator. As compared with existing results, values of SNR versus the input signal amplitude and the oversampling ratio for the suggested system are about 6dB higher then previously reported results respectively. Furthermore, this approach achieves an about 60dB input dynamic range.

  • PDF

Quantitative Analysis of EMG Amplitude Estimator for Surface EMG Signal Recorded during Isometric Constant Voluntary Contraction (등척성 일정 자의 수축 시에 기록한 표면근전도 신호에 대한 근전도 진폭 추정기의 정량적 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.843-850
    • /
    • 2017
  • The EMG amplitude estimator, which has been investigated as an indicator of muscle force, is utilized as the control input to artificial prosthetic limbs. This paper describes an application of the optimal EMG amplitude estimator to the surface EMG signals recorded during constant isometric %MVC (maximum voluntary contraction) for 30 seconds and reports on assessing performance of the amplitude estimator from the application. Surface EMG signals, a total of 198 signals, were recorded from biceps brachii muscle over the range of 20-80%MVC isometric contraction. To examine the estimator performance, a SNR(signal-to-noise ratio) was computed from each amplitude estimate. The results of the study indicate that ARV(average rectified value) and RMS(root mean square) amplitude estimation with forth order whitening filter and 250[ms] moving average window length are optimal and showed the mean SNR improvement of about 50%, 40% and 20% for each 20%MVC, 50%MVC and 80%MVC surface EMG signals, respectively.