• Title/Summary/Keyword: Input/output Control

Search Result 2,504, Processing Time 0.035 seconds

An alternative architecture for application-driven fuzzy systems

  • Pedrycz, W.;de Oliveira, J. Valente
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.985-988
    • /
    • 1993
  • An alternative approach to the design of application-driven fuzzy systems is proposed. A broad class of fuzzy systems applications requires a certain fuzzy partition of the input space while it demands for simple numerical quantities. For this class, a dedicated fuzzy system archictecture is presented and a design strategy is proposed. Both the single-input/single-output and multi-input/multi-output cases are considered. Numerical analysis are complete illustrating several aspects of the proposed framework.

  • PDF

Model Predictive Control of Three-Phase Inverter for Uninterruptible Power Supply Applications under a Hexagonal Input Constraint Region (육각형 입력제약 공간을 이용한 무정전 전원장치의 모델예측제어)

  • Kim, Seok-Kyoon;Kim, Jung-Su;Lee, Young Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Using the classical cascade voltage control strategy, this paper proposes an analytical solution to an MPC (Model Predictive Control) problem with a hexagonal input constraint set for the inner-loop to regulate the output voltage of the UPS (Uninterruptible Power Supply). Focus is placed on how to deal with the hexagonal input constraint set without any approximation. Following the conventional cascade voltage control strategy, the PI (Proportional-Integral) controller is used in the outer-loop in order to regulate the output voltage. The simulation results illustrate that the capacitor voltage rapidly goes to its reference in a satisfactory manner while keeping other state variables bounded under an unexpected load changes.

Bilateral Controller for Time-varying Communication Delay: Time Domain Passivity Approach (시변 시간지연 하에서 안정성을 보장하는 양방향 원격제어기 : 시간영역 수동성 기법)

  • Ryu, Jee-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1099-1105
    • /
    • 2007
  • In this paper, modified two-port time-domain passivity approach is proposed for stable bilateral control of teleoperators under time-varying communication delay. We separate input and output energy at each port of a bilateral controller, and propose a sufficient condition for satisfying the passivity of the bilateral controller including time-delay. Output energy at the master port should be less than the transmitted input energy from the slave port with time-delay, and output energy at the slave port should be less than the transmitted input energy from the master port with time-delay. For satisfying above two conditions, two passivity controllers are attached at each port of the bilateral controller. A packet reflector with wireless internet connection is used to introduce serious time-varying communication delay of teleoperators. Average amount of time-delay was about 190(msec) for round trip, and varying between 175(msec) and 275(msec). Moreover some data packet was lost during the communication due to UDP data communication. Even under the serious time-varying delay and packet loss communication condition, the proposed approach can achieve stable teleoperation in free motion and hard contact as well.

Design of unknown input observer of wheelbase preview control of commercial vehicles (상용 차량의 축거 예견 제어를 위한 미지 입력 관측기 설계)

  • 노현석;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.892-895
    • /
    • 1996
  • An unknown input observer is proposed that can be used in wheelbase preview control of commercial vehicles. The preview and state information, required to calculate actuator force, are reconstructed from the measurement variables such as heave and pitch acceleration. Gain matrix of observer is optimally selected so that influence of system and measurement noises on the estimation error can be minimized. Estimated preview information requires low pass filtering to eliminate high frequency components resulting from differentiation of noisy output signals. Effectiveness of the proposed method is demonstrated by numerical simulation of half car model.

  • PDF

Observer-Based Output Feedback Stochastic Stabilization for T-S Fuzzy Systems with Input Delay (입력지연을 갖는 T-S 퍼지 시스템의 관측기기반 출력궤환 확률적 안정화)

  • Lee, Sang In;Park, Jin Bae;Joo, Young Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.3
    • /
    • pp.298-303
    • /
    • 2004
  • This paper deals with a stochastic stabilization of observer-based output-feedback control Takagi-Sugeno (T-S) fuzzy system with Markovian input delay. The finite Markovian process is adopted to model the input delay of the overall control system. It is assumed that the zero and hold devices are used for control input. The continuous-time T-S fuzzy system with the Markovian input delay is discretized for easy handling delay, accordingly, the discretized T-S fuzzy system is represented by a discrete-time T-S fuzzy system with jumping parameters. The stochastic stabilizability of the jump T-S fuzzy system is derived and formulated in terms of linear matrix inequalities (LMIs). The usefulness of the proposed algorithm is also certificated by simulation of 2 degree of freedom helicopter model.

Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter (고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수)

  • Kim, Kwang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • Matrix converters have been studied for eliminating dc link of conventional converter-inverter system, and various undulation strategy have been proposed. Therefore, matrix converter have no energy storage component except for small ac later for the elimination of switching ripple, and can be made compact and highly reliable compare with the do link inverter system. Matrix converter, however, directly connected the input and the output terminals by bidirectional static switch. As a result if the input voltage are asymmetrical, and contain harmonics, the influence of the distortions directly appear on the output terminal. This problem is a major obstacle to the matrix converter. A new control method using average comparison strategy have been proposed in this paper. This control method realizes sinusoidal input and output current unity input displacement factor regardless of load power factor. Moreover, compensation of the asymmetrical and/or harmonic containing input voltage is automatically realized, and calculation time of control function is reduced.

Design of the optimal inputs for parameter estimation in linear dynamic systems (선형계통의 파라미터 추정을 위한 최적 입력의 설계)

  • 양흥석;이석원;정찬수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.73-77
    • /
    • 1986
  • Optimal input design problem for linear regression model with constrained output variance has been considered. It is shown that the optimal input signal for the linear regression model can also be realized as an ARMA process. Monte-Carlo simulation results show that the optimal stochastic input leads to comparatively better estimation accuracy than white input signal.

  • PDF

Identification of Volterra Kernels of Nonlinear Van do Vusse Reactor

  • Kashiwagi, Hiroshi;Rong, Li
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.2
    • /
    • pp.109-113
    • /
    • 2002
  • Van de Vusse reactor is known as a highly nonlinear chemical process and has been considered by a number of researchers as a benchmark problem for nonlinear chemical process. Various identification methods for nonlinear system are also verified by applying these methods to Van de Vusse reactor. From the point of view of identification, only the Volterra kernel of second order has been obtained until now. In this paper, the authors show that Volterra kernels of nonlinear Van de Vusse reactor of up to 3rd order are obtained by use of M-sequence correlation method. A pseudo-random M-sequence is applied to Van de Vusse reactor as an input and its output is measured. Taking the crosscorrelation function between the input and the output, we obtain up to 3rd order Volterra kernels, which is the highest order Volterra kernel obtained until now for Van de Vusse reactor. Computer simulations show that when Van de Vusse chemical process is identified by use of up to 3rd order Volterra kernels, a good agreement is observed between the calculated output and the actual output.

Study on 2 dimensional Control Chart and Search interrelation Independent variable and dependent variable by using control chart considered simultaneously (2차원 관리도와 관리도를 이용한 독립변수와 종속변수의 관계연구)

  • Ree, Sang-Bok;Kim, Myung-Hoon
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.11a
    • /
    • pp.195-198
    • /
    • 2006
  • In this paper, we propose a 2dimension Control Chart. Suggested which Control chart augments Schwart Control chart which is 1-dimensional and Independent variable and dependent variable interrelationship by using control chart. Schwart control chart cannot use input variable and output variable together. In this paper, we try to analysis input variable and output variable dependent and effect. So called 2-dimensional control char.

  • PDF

A New $H_2$ Bound for $H_{\infty}$ Entropy

  • Zhang, Hui;Sun, Youxian
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.4
    • /
    • pp.620-625
    • /
    • 2008
  • The $H_{\infty}$ entropy in $H_{\infty}$ control theory is discussed based on investigating information transmission in continuous-time linear stochastic systems. It is proved that the stabilizing feedback does not change the time-average information transmission between system input and output, and the $H_{\infty}$ entropies of open- and closed-loop stable transfer functions are bounded by mutual information rate between input and output in the open-loop system. Furthermore, a new $H_2$ upper bound for $H_{\infty}$ entropy is introduced with a numerical example. Thus the $H_{\infty}$ entropy of a stable transfer function is sandwiched between $H_2$ norms of the original system and a static feedback system.