• 제목/요약/키워드: Input/output Control

검색결과 2,504건 처리시간 0.033초

Input and output filter design of current source PWM converter for high-precision magnet power supply (고정밀 자석전원을 위한 전류형 PWM 컨버터의 입출력 필터설계)

  • 김효성;최재호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제45권1호
    • /
    • pp.30-41
    • /
    • 1996
  • Current Source(CS) PWM converter is appropriate for the magnet power supply system which requests high power and high precision current control. Input and output filters should be installed to eliminate the current or voltage harmonics caused by the PWM switching for the CS PWM converter. But the input/output filters limit the output DC current range and may destroy the system with filter resonance, and make the system equation more complicated. In this paper, systematic and simple filter design method which considers not only the harmonic attenuation but also the total system good transfer function characteristics in the dc filter. The simulated and experimental results verify the proposed theory. (author). refs., figs., tabs.

  • PDF

Torque Trajectory Control of Interior PM Synchronous Motor Using Adaptive Input-Output Linearization Technique (적응 입출력 선형화 제어 기법을 이용한 매입형 영구 자석 동기 전동기의 토오크 궤적 제어)

  • Kim, Kyeong-Hwa;Baik, In-Cheol;Kim, Hyun-Soo;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.578-581
    • /
    • 1996
  • A torque trajectory control of the IPM synchronous motor using an adaptive input-output linearization technique is proposed. The input-output linearization is performed using the estimated torque output with the knowledge of machine parameters. The linearized model gives the output torque error under the variation of the flux linkage. To give a good torque tracking in the presence of the flux linkage variation, the flux linkage will be estimated where the adaptation law h derived by the Popov's hyperstability theory and the positivity concept. This estimated value is also used for the generation of the d-axis current command for the maximum torque control. Thus, a good torque tracking and the exact maximum torque-per-current operation will be obtained.

  • PDF

Performance analysis of a loss priority control scheme in an input and output queueing ATM switch (입출력 단에 버퍼를 가지는 ATM 교환기의 손실우선순위 제어의 성능 분석)

  • 이재용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제22권6호
    • /
    • pp.1148-1159
    • /
    • 1997
  • In the broadband integrated service digital networks (B-ISDN), ATM switches hould be abld to accommodate diverse types of applications ith different traffic characteristics and quality ddo services (QOS). Thus, in order to increase the utilization of switches and satisfy the QOS's of each traffic type, some types of priority control schemes are needed in ATM switches. In this paper, a nonblocking input and output queueing ATm switch with capacity C is considered in which two classes of traffics with different loss probability constraints are admitted. 'Partial push-out' algorithm is suggested as a loss priority control schemes, and the performance of this algorithm is analyzed when this is adopted in input buffers of the switch. The quque length distribution of input buffers and loss probabilities of each traffic are obtained using a matrix-geometric solution method. Numerical analysis and simulation indicate that the utilization of the switch with partial push-out algorithm satisfying the QOS's of each traffic is much higher than that of the switch without control. Also, the required buffer size is reduced while satisfying the same QOS's.

  • PDF

LVDS I/O Cells with Rail-to-Rail Input Receiver

  • Lim, Byong-Chan;Lee, Sung-Ryong;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.567-570
    • /
    • 2002
  • The LVDS (Low Voltage Differential Signaling) I/O cells, fully compatible with ANSI TIA/ EIA-644 LVDS standard, are designed using a 0.35${\mu}m$ standard CMOS technology. With a single 3V supply, the core cells operate at 1.34Gbps and power consumption of the output driver and the input receiver is 10. 5mW and 4.2mW, respectively. In the output driver, we employ the DCMFB (Dynamic Common-Mode FeedBack) circuit which can control the DC offset voltage of differential output signals. The SPICE simulation result of the proposed output driver shows that the variation of the DC offset voltage is 15.6% within a permissible range. In the input receiver, the proposed dual input stage with a positive feedback latch covers rail-to-rail input common-mode range and enables a high-speed, low-power operation. 5-channels of the proposed LVDS I/O pair can handle display data up to 8-bit gray scale and UXGA resolution.

  • PDF

The Design of a I/O Interface Circuits for the Signal Driver of the Engine Control Relays and the Output Signal Monitoring of Diesel Generator (디젤 발전기 출력 신호의 모니터링 및 엔진제어 릴레이 구동을 위한 입출력 인터페이스 회로 설계)

  • Joo, Jae-hun;Kim, Jin-ae;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2009년도 춘계학술대회
    • /
    • pp.547-550
    • /
    • 2009
  • This paper presents a digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for Emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes pick-up coil signal.

  • PDF

A new PWM method for instantaneous output current control of matrix converters with sinusoidal input current

  • Sung K. M.;Kobayashi K;Sato Y.
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.179-183
    • /
    • 2001
  • This paper presents a simple current control strategy for matrix converters based on the extension of PWM method for inverters. A novel and efficient PWM algorithm is developed. The algorithm is verified through simulation and experiments employing a 2-kVA prototype. The results of simulation and experiment prove the instantaneous control capability of the output current with the sinusoidal input current.

  • PDF

An Optimal Threshold Control in an Open Network of Queues (개방대기 네트웍에서의 최적 Threshold 제어)

  • Kim, Sung-Chul
    • Journal of Korean Institute of Industrial Engineers
    • /
    • 제17권2호
    • /
    • pp.107-113
    • /
    • 1991
  • This article develops a control model for an open queueing network in terms of both the input and the output processes with stochastic intensities. The input and the output intensities are subject to some capacity limits and optimum control is characterized by a threshold type with a finite upper barrier. A discounted profit is used as a decision criteria, which is revenue minus operating and holding cost.

  • PDF

Input-Ouput Linearization and Control of Nunlinear System Using Recurrent Neural Networks (리커런트 신경 회로망을 이용한 비선형 시스템의 입출력 선형화 및 제어)

  • 이준섭;이홍기;심귀보
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 한국퍼지및지능시스템학회 1997년도 춘계학술대회 학술발표 논문집
    • /
    • pp.185-188
    • /
    • 1997
  • In this paper, we execute identification, linearization, and control of a nonlinear system using recurrent neural networks. In general nonlinear control system become complex because of nonlinearity and uncertainty. And though we compose nonlinear control system based on the model, it is difficult to get good control ability. So we identify the nonlinear control system using the recurrent neural networks and execute feedback linearization of identified model, In this process we choose the optional linear system, and the system which will have to be feedback linearized if trained to follow the linearity between input and output of the system we choose. We the feedback linearized system by applying standard linear control strategy and simulation. And we evaluate the effectiveness by comparing the result which is linearized theoretically.

  • PDF

Fuzzy Modelling and Fuzzy Controller Design with Step Input Responses and GA for Nonlinear Systems (비선형 시스템의 계단 입력 응답과 GA를 이용한 퍼지 모델링과 퍼지 제어기 설계)

  • Lee, Wonchang;Kang, Geuntaek
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • 제27권1호
    • /
    • pp.50-58
    • /
    • 2017
  • For nonlinear control system design, there are many studies based on TSK fuzzy model. However, TSK fuzzy modelling needs nonlinear dynamic equations of the object system or a data set fully distributed in input-output space. This paper proposes an modelling technique using only step input response data. The technique uses also the genetic algorithm. The object systems in this paper are nonlinear to control input variable or output variable. In the case of nonlinear to control input, response data obtained with several step input values are used. In the case of nonlinear to output, step input response data and zero input response data are used. This paper also presents a fuzzy controller design technique from TSK fuzzy model. The effectiveness of the proposed techniques is verified with numerical examples.

A Single-Phase Embedded Z-Source DC-AC Inverter by Asymmetric Voltage Control (비대칭 전압 제어를 이용한 단상 임베디드 Z-소스 DC-AC 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.306-314
    • /
    • 2012
  • In case of the conventional DC-AC inverter using two DC-DC converters with unipolar output capacitor voltages, for generating the AC output voltage, the output capacitor voltages of its each DC-DC converter must be higher than the DC input voltage. To solve this problem, this paper proposes a single-phase DC-AC inverter using two embedded Z-source converters with bipolar output capacitor voltages. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The AC output voltage is obtained by the difference of the output capacitor voltages of each converter. Though the output capacitor voltage of converter is relatively low compared to the conventional method, it can be obtained the same AC output voltage. Moreover, by controlling asymmetrically the output capacitor voltage, the AC output voltage of the proposed system is higher than the DC input voltage. To verify the validity of the proposed system, a DSP(TMS320F28335) based single-phase embedded Z-source DC-AC inverter was made and the PSIM simulation was performed under the condition of the DC source 38V. As controlled symmetrically and asymmetrically the output capacitor voltages of each converter, the proposed inverter could produce the AC output voltage with sinusoidal waveform. Particularly, in case of asymmetric control, a higher AC output voltage was obtained. Finally, the efficiency of the proposed system was measured as 95% and 97% respectively in case of symmetric and asymmetric control.