• Title/Summary/Keyword: Inner length

Search Result 762, Processing Time 0.029 seconds

J-integral for subsurface crack in circular plate with inner hole under rolling and sliding contact (구름 및 미끄럼 접촉하의 중공원판의 표면하층균열에 대한 J-적분)

  • Lee, Kang-Yong;Kim, June-Yeop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1149-1155
    • /
    • 1997
  • J-integral for a subsurface horizontal crack in a circular plate with an inner hole under rolling line contact is evaluated according to loading positions with various load conditions, crack length and crack location. Two-dimensional crack is modeled, and the relation between Tresca stress for uncracked model and J-integral is discussed. The loading location which gives the maximum J-integral depends on load condition and crack location, and the presence of friction force increases Tresca stress and J-integral near the surface. Regardless of friction force, crack location that gives maximum J-integral is the same as that of maximum Tresca stress in an uncracked model, and the value of J-integral is propotional to crack length. It is also showed that the variation of an inner radius of a disk does not effect J-integral value.

Walking behaviors for stroke survivors: comparison between straight line and curved path

  • Hwang, Wonjeong;Choi, Bora;Hwang, Sujin
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.141-145
    • /
    • 2019
  • Objective: The purpose of this study was to compare walking conditions (straight line and curved path) on walking patterns in persons who had experienced hemiplegic stroke and to determine whether if they adapt their walking pattern and performances according to changes in environmental conditions. Design: Cross-sectional study. Methods: Forty-four hemiplegic stroke survivors participated in this study. This study measured walking performance in three different walking conditions, such as straight walking, the more-affected leg in the inner curve walking, and less-affected leg in the inner curve walking conditions, and a 2-dimentional gait analysis system was used as a primary measurement. This study also measured secondary clinical factors including the Timed Up-and-Go Test, the Trunk Impairment Scale, and the Dynamic Gait Index. Results: After analyzing, cadence and step length of the less-affected side, stride length in the more-affected side, and stride length in less-affected side were significantly different among the three different walking conditions in this study (p<0.05), but other temporospatial parameters were not significant. Cadence was the largest in the straight walking condition. Step length in the less-affected side, stride length in the more-affected side, and stride length in less-affected side were also the longest in the straight walking condition. Conclusions: The results of the study suggest that hemiplegic stroke survivors show walking adaptability according to changes in walking demands and conditions, and moreover, cadence and step and stride lengths were significantly different between straight and curved walking conditions.

Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger (액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.

A Study on Design Variables for Increasing the Breaking Strength of Synthetic Fiber Chain

  • Kyeongsoo Kim;Seonjin Kim;Hyunwoo Cho;Dokyoun Kim;Yongjun Kang;Taewan Kim
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.31-37
    • /
    • 2023
  • In this study, a fiber chain was developed to replace a steel chain using high-modulus polyethylene DM20. The pick count, wrapping count, and inner length were selected as the main design variables of the fiber chain and were analyzed to increase the breaking strength. Orthogonal array experiments were conducted, and the results were analyzed with respect to the breaking strength. The analysis revealed that the pick count and wrapping count had meaningful effects at significance levels within 5%. The main effect analysis revealed that a smaller pick count, larger wrapping count, and longer inner length caused the breaking strength to increase. With the wrapping count fixed at 1, a pick count less than -0.65, and an inner length greater than 0.38, the breaking strength was calculated to be greater than 300 kN. These results are expected be important factors in the derivation of an optimal combination of design variables to attain a fiber chain with a targeted strength.

Molecular Characterization and Tissue-specific Expression of a Novel FKBP38 Gene in the Cashmere Goat (Capra hircus)

  • Zheng, X.;Hao, X.Y.;Chen, Y.H.;Zhang, X.;Yang, J.F.;Wang, Z.G.;Liu, D.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.25 no.6
    • /
    • pp.758-763
    • /
    • 2012
  • As a member of a subclass of immunophilins, it is controversial that FKBP38 acts an upstream regulator of mTOR signaling pathway, which control the process of cell-growth, proliferation and differentiation. In order to explore the relationship between FKBP38 and mTOR in the Cashmere goat (Capra hircus) cells, a full-length cDNA was cloned (GenBank accession number JF714970) and expression pattern was analyzed. The cloned FKBP38 gene is 1,248 bp in length, containing an open reading frame (ORF) from nucleotide 13 to 1,248 which encodes 411 amino acids, and 12 nucleotides in front of the initiation codon. The full cDNA sequence shares 98% identity with cattle, 94% with horse and 90% with human. The putative amino acid sequence shows the higher homology which is 98%, 97% and 94%, correspondingly. The bioinformatics analysis showed that FKBP38 contained a FKBP_C domain, two TPR domains and a TM domain. Psite analysis suggested that the ORF encoding protein contained a leucine-zipper pattern and a Prenyl group binding site (CAAX box). Tissue-specific expression analysis was performed by semi-quantitative RT-PCR and showed that the FKBP38 expression was detected in all the tested tissues and the highest level of mRNA accumulation was detected in testis, suggesting that FKBP38 plays an important role in goat cells.

Non-Constructive analysis for the cover and inner paper in the Taebaeksan volume of Joseon Dynasty annals (조선왕조실록 태백산사고본 표지 및 내지의 비파괴적 특성 연구)

  • Cho, Jung-Hye;Kim, Kang-Jae;Eom, Tae-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.42 no.3
    • /
    • pp.28-36
    • /
    • 2010
  • Today We have three full series of the annals of Joseon Dynasty. Taebaeksan volume which is one of them shows comparatively good maintenance but Taebaeksan volume also decomposed in patches. The size of cover and inner paper were increased in late Joseon Dynasty, but the weight, thickness and basis weight bears no relation to each other. The oxidation index of paper in annals of pre-periods of King Sunjo shows very high value. After the annals of King Sunjo, the oxidation index of paper is very similar to today's Hanji. L.a.b values of inner paper in the Taebaeksan volume are similar generally. The average length of fiber using image analysis soft ware is 8.08~9.92 mm, that like immediate value of measurement. The air fraction of fiber's range is 1.20~2.12%. It lower than today's Hanji. After considering the factors of the length of fiber, air fraction and FE-SEM, we reached that no difference between raw material of inner paper in the Taebaeksan volume.

Reconsideration on the Classification of Korean Anurans, Family Hylidae (한국산 청개구리과 (Family Hylidae)분류의 재검토)

  • 양서영
    • The Korean Journal of Zoology
    • /
    • v.5 no.1
    • /
    • pp.35-38
    • /
    • 1962
  • Two subspecies are known to Family Hylidae(Order Anura) in Korea : namely , Hylaarborea japonica GUENTHER and H.a.stepheni BOULENGER, and they have been hitherto distinguished as different subspecies from four characteristics : the rate of interorbital to incternasal length, the rate of diameter of tympanum to diameter of 3 rd finger disc, the rate of the length of inner metatarsal tubercle to diameter of 3 rd finger disc, and the rate of inner metatarsal tubercle to the length of lst toe. The author has compared the above to subspecies for the characteristics with 123 individuals collected from ten different localities in Korea and has found that their fluctation curves overlap each other. The author considers, therefore, that the four characteristics could not be assumed as keys for the classification of the two subspecies and has reached the conclusion that these two subspecies should be regarded as one subspecies and Hyla arborea japonica GUENTHER should be given to both of them as the subspecies name.

  • PDF

Recombinant Goat VEGF164 Increases Hair Growth by Painting Process on the Skin of Shaved Mouse

  • Bao, Wenlei;Yin, Jianxin;Liang, Yan;Guo, Zhixin;Wang, Yanfeng;Liu, Dongjun;Wang, Xiao;Wang, Zhigang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.9
    • /
    • pp.1355-1359
    • /
    • 2014
  • To detect goat vascular endothelial growth factor (VEGF)-mediated regrowth of hair, full-length VEGF164 cDNA was cloned from Inner Mongolia cashmere goat (Capra hircus) into the pET-his prokaryotic expression vector, and the recombinant plasmid was transferred into E. coli BL21 cells. The expression of recombinant $6{\times}his-gVEGF164$ protein was induced by 0.5 mM isopropyl thio-${\beta}$-D-galactoside at $32^{\circ}C$. Recombinant goat VEGF164 (rgVEGF164) was purified and identified by western blot using monoclonal anti-his and anti-VEGF antibodies. The rgVEGF164 was smeared onto the dorsal area of a shaved mouse, and we noted that hair regrowth in this area was faster than in the control group. Thus, rgVEGF164 increases hair growth in mice.

Ultra-High Frequency Characteristics of Double-Wall Carbon Nanotube Resonator with Different Length (서로 다른 길이를 갖는 이중벽 탄소 나노튜브 공진기의 초고주파 주파수 특성)

  • Kim, Jin-Tae;Lee, Jun-Ha;Lee, Kang-Ho;Choi, Jong-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.175-180
    • /
    • 2010
  • In this paper, we have investigated ultrahigh frequency nano-mechanical resonators, made of DWCNTs with various wall lengths, via classical molecular dynamics simulations. We have aimed our analysis on the frequency variations of these resonators with the DWCNT wall lengths. The results show that the variations can be well fitted by either the Pearson VII function when the resonant frequency of normalized by its maximum frequency is plotted as a function of the inner/outer wall length ratio L5/L10 for different values of the outer wall length L10, and the Gauss distribution function when the resonant frequency of normalized by its maximum frequency is plotted as a function of the outer/inner wall length ratio for different values of the inner wall length.

Performance Comparison of Concatenated Codes with Different Inner Decoding Schemes in Frequency-Hopping Spread Spectrum Multiple-Access Channels (주파수 도약 대역확산 다중접속 채널에서 내 부호 복호화 기법에 따른 쇄상부호의 성능 비교)

  • Lee, Ye Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.114-118
    • /
    • 2014
  • In this paper, we analyze the performance of a concatenated code with two different inner decoding schemes. One is the error-detecting inner decoding, and the other is the error-detecting-and-correcting inner decoding scheme. We compare the performances of the two decoding schemes for finite and infinite block length cases when the concatenated code is applied to slow frequency-hopping spread-spectrum multiple access (FH-SSMA) communication systems.