• Title/Summary/Keyword: Inner defects

Search Result 176, Processing Time 0.024 seconds

Improvement of Flight Safety by Horizontal Stabilizer Design Improvement of Rotorcraft (회전익 항공기 수평 안정판의 설계 개선을 통한 비행 안전성 향상)

  • Lee, Yoon-Woo;Kim, Dae-Han;Jang, Min-Wook;Hyun, Young-Jin;Lee, Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.134-141
    • /
    • 2019
  • This paper is a study on design improvement of rotorcraft horizontal stabilizer. The rotorcraft horizontal stabilizer stabilizes the behavior of the pitch, yaw, etc. from the aircraft. Because of this role, horizontal stabilizers are a major component (Flight Safety Part) that affects flight safety on rotorcraft. However, when the rotorcraft was operated in domestic, cracks were found in the inner structure of the horizontal stabilizer and design improvement was needed. In this paper, we identified the two causes of the horizontal stabilizer crack defects through fracture analysis and structural analysis. The first is the tightening torque when the bolt is tightened, and the second is the lead-lag behavior of aircraft. In order to improve these two causes, bolt fastening method, flange structure and thickness were changed and composite ring was applied. In order to verify the design improvement, the structural analysis was performed and the structural strength was improved. Also Fatigue analysis of the internal structure (Rib 1) was performed and it was confirmed that the requirements were satisfied.

THE EFFECT OF NEW BONE FORMATION OF ONLAY BONE GRAFT USING VARIOUS GRAFT MATERIALS WITH A TITANIUM CAP ON THE RABBIT CALVARIUM (가토의 두개골에서 티타늄 반구를 이용한 다양한 onlay bone graft시 골형성 능력)

  • Park, Young-Jun;Choi, Guen-Ho;Jang, Jung-Rok;Jung, Seung-Gon;Han, Man-Seung;Yu, Min-Gi;Kook, Min-Suk;Park, Hong-Ju;Ryu, Sun-Youl;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.469-477
    • /
    • 2009
  • Purpose: This study was performed to evaluate the effect of various graft materials used with a titanium cap on the ability of new bone formation in the rabbit calvarium. Materials and Methods: A total of 32 sites of artificial bony defects were prepared on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter. Each rabbit had two defect sites. 0.2 mm deep grooves were formed on the calvaria of sixteen rabbits by using a trephine bur 8 mm in diameter for the fixation of a titanium cap. The treatments were performed respectively as follows: without any graft for the control group (n=8), autogenous iliac bone graft for experimental group 1 (n=8), alloplastic bone graft ($SynthoGraft^{(R)}$, USA) for experimental group 2 (n=8), and xenogenic bone graft ($NuOss^{(R)}$, USA) for experimental group 3 (n=8). After the treatments, a titanium cap (8 mm in diameter, 4 mm high, and 0.2 mm thick) was fixed into the groove. At the third and sixth postoperative weeks, rabbits in each group were sacrificed for histological analysis. Results: 1. In gross examination, the surgical sites showed no signs of inflammation or wound dehiscence, and semicircular-shaped bone remodeling was shown both in the experimental and control groups. 2. In histological analysis, the control group at the third week showed bone remodeling along the inner surface of the cap and at the contact region of the calvarium without any specific infiltration of inflammation tissue. Also, there was no soft tissue infiltration. Bone remodeling was observed around the grafted bone and along the inner surface of the titanium cap in experimental group 1, 2, and 3. 3. Histologically, all groups at the sixth week showed the increased area of bone remodeling and maturation compared to those at the third week. In experimental group 2, the grafted bone was partially absorbed by multi nucleated giant cells and new bone was formed by osteoblasts. In group 3, however, resorption of the grafted bone was not observed. 4. Autogenous bone at the third and sixth week showed the most powerful ability of new bone formation. The size of newly formed bone was in decreasing order by autogenous, alloplastic, and heterogenous bone graft. There was no statistically significant difference among autogenous, alloplastic, and heterogenous bones(p>0.05). Summary: This result suggests that autogenous bone is the best choice for new bone formation, but when autogenous bone graft is in limited availability, alloplastic and xenogenic bone graft also can be an alternative bone graft material to use with a suitably guided membrane.

Treatment of Benign Bone Lesions with Autologous Bone Marrow Stromal Cell Transplantation (자가 골수 기질 세포 이식을 이용한 장관골 양성 골 병변의 치료)

  • Rhee, Seung-Koo;Kang, Yong-Koo;Kim, Yong-Sik;Bahk, Won-Jong;Chung, Yang-Guk;Kim, Hyoung-Jun;Ok, Ji-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • Purpose: We analyzed the result of autologous bone marrow stromal cell transplantation with or without cancellous chip bone allograft for benign long bone lesions. Materials and methods: Since July 1996, eight benign bone lesions treated by curettage, cancellous chip bone allograft and bone marrow or marrow stromal cell transplantation were observed for resolution of clinical symptoms, new bone formation and consolidation. There were 6 males and 2 females. Average age was 24 (range 8 to 47) years old. Histologic diagnoses were 5 fibrous dysplasia, 2 simple bone cysts and one chondroblastoma and fibrous cortical defect each. Mean follow-up period was 16.3 (range 3 to 84) months. Results: In all four symptomatic patients, the pain was subsided in two weeks after surgery. New bone formation in the lesion was observed at 4 weeks, which incorporated into surrounding normal bone around 8 weeks. There were one pathologic fracture through the lesion at 3 weeks and one recurrence of simple bone cyst at 5 months postoperatively. Conclusion: Bone marrow or marrow stromal cell transplantation for bone defects from curettage of benign bone lesions, with or without cancellous chip bone allograft revealed rapid healing. Though it was the result of short-term follow up, it supports that bone marrow stromal cell transplantation will be very useful for the treatment of benign long bone cysts or other lesions. The complete curettage of inner cystic wall is important to prevent later recurrence, and the rigid internal fixation is also needed in selected high risk lesions of fracture.

  • PDF

COATED PARTICLE FUEL FOR HIGH TEMPERATURE GAS COOLED REACTORS

  • Verfondern, Karl;Nabielek, Heinz;Kendall, James M.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.603-616
    • /
    • 2007
  • Roy Huddle, having invented the coated particle in Harwell 1957, stated in the early 1970s that we know now everything about particles and coatings and should be going over to deal with other problems. This was on the occasion of the Dragon fuel performance information meeting London 1973: How wrong a genius be! It took until 1978 that really good particles were made in Germany, then during the Japanese HTTR production in the 1990s and finally the Chinese 2000-2001 campaign for HTR-10. Here, we present a review of history and present status. Today, good fuel is measured by different standards from the seventies: where $9*10^{-4}$ initial free heavy metal fraction was typical for early AVR carbide fuel and $3*10^{-4}$ initial free heavy metal fraction was acceptable for oxide fuel in THTR, we insist on values more than an order of magnitude below this value today. Half a percent of particle failure at the end-of-irradiation, another ancient standard, is not even acceptable today, even for the most severe accidents. While legislation and licensing has not changed, one of the reasons we insist on these improvements is the preference for passive systems rather than active controls of earlier times. After renewed HTGR interest, we are reporting about the start of new or reactivated coated particle work in several parts of the world, considering the aspects of designs/ traditional and new materials, manufacturing technologies/ quality control quality assurance, irradiation and accident performance, modeling and performance predictions, and fuel cycle aspects and spent fuel treatment. In very general terms, the coated particle should be strong, reliable, retentive, and affordable. These properties have to be quantified and will be eventually optimized for a specific application system. Results obtained so far indicate that the same particle can be used for steam cycle applications with $700-750^{\circ}C$ helium coolant gas exit, for gas turbine applications at $850-900^{\circ}C$ and for process heat/hydrogen generation applications with $950^{\circ}C$ outlet temperatures. There is a clear set of standards for modem high quality fuel in terms of low levels of heavy metal contamination, manufacture-induced particle defects during fuel body and fuel element making, irradiation/accident induced particle failures and limits on fission product release from intact particles. While gas-cooled reactor design is still open-ended with blocks for the prismatic and spherical fuel elements for the pebble-bed design, there is near worldwide agreement on high quality fuel: a $500{\mu}m$ diameter $UO_2$ kernel of 10% enrichment is surrounded by a $100{\mu}m$ thick sacrificial buffer layer to be followed by a dense inner pyrocarbon layer, a high quality silicon carbide layer of $35{\mu}m$ thickness and theoretical density and another outer pyrocarbon layer. Good performance has been demonstrated both under operational and under accident conditions, i.e. to 10% FIMA and maximum $1600^{\circ}C$ afterwards. And it is the wide-ranging demonstration experience that makes this particle superior. Recommendations are made for further work: 1. Generation of data for presently manufactured materials, e.g. SiC strength and strength distribution, PyC creep and shrinkage and many more material data sets. 2. Renewed start of irradiation and accident testing of modem coated particle fuel. 3. Analysis of existing and newly created data with a view to demonstrate satisfactory performance at burnups beyond 10% FIMA and complete fission product retention even in accidents that go beyond $1600^{\circ}C$ for a short period of time. This work should proceed at both national and international level.

Enhanced PHB Accumulation in Photosystem- and Respiration-defective Mutants of a Cyanobacterium Synechocystis sp. PCC 6803 (Synechocystis sp. PCC 6803의 에너지 대사 결함 돌연변이 균주에서의 Poly(3-hydroxybutyrate) 축적량 증진)

  • Kim Soo-Youn;Choi Gang Guk;Park Youn Il;Park Young Mok;Yang Young Ki;Rhee Young Ha
    • Korean Journal of Microbiology
    • /
    • v.41 no.1
    • /
    • pp.67-73
    • /
    • 2005
  • Photoautotrophic bacteria are promising candidates for the production of poly(3-hydroxybutyrate) (PHB) since they can address the critical problem of substrate costs. In this study, we isolated 25 Tn5-inserted mutants of the Synechocystis sp. PCC 6803 which showed enhanced PHB accumulation compared to the wild-type strain. After 5-days cultivation under nitrogen-limited mixotrophic conditions, the intracellular levels of PHB content in these mutants reached up to $10-30\%$ of dry cell weight (DCW) comparable to $4\%$ of DCW in the wild-type strain. Using the method of inverse PCR, the affected genes of the mutants were mapped on the completely known genome sequence of Synechocystis sp. PCC 6803. As a result, the increased PHB accumulation in 5 mutants were found to be resulted from defects of genes coding for NADH-ubiquinone oxidoreductase, O-succinylbenzoic-CoA ligase, photosystem II PsbT protein or histidine kinase, which are involved in photosystem in thylakoid inner membrane of the cell. The values of $NAD(P)H/NAD(P)^+$ ratio in the cells of these mutants were much higher than that of the wild-type strain as measured by using pulse-amplitude modulated fluorometer, suggesting that PHB synthesis could be enhanced by increasing the level of cellular NAD(P)H which is a limiting substrate for NADPH-dependent acetoacetyl-CoA reductase. From these results, it is likely that NAD(P)H would be a limiting factor for PHB synthesis in Synechocystis sp. PCC 6803.

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF