• 제목/요약/키워드: Inner cover

검색결과 106건 처리시간 0.022초

커버 플레이트를 이용한 이종 3겹 저항 점 용접성 평가 (Characteristics of Dissimillar Three-Sheet Resistance Spot Welding for Advanced High Strength Steel with Cover Plate)

  • 심정현;이세헌
    • 한국생산제조학회지
    • /
    • 제25권5호
    • /
    • pp.373-379
    • /
    • 2016
  • Low carbon steel is usually used as the outer panel with low base metal resistance compared to the inner reinforced panel made with high strength steel, which makes it difficult to form a robust nugget. To overcome welding problems of a dissimilar three-sheet combination made of SGACEN, DP980 and CP1180, a cover plate was inserted between the upper electrode and SGACEN. The quality of the nugget was analyzed by comparing the welding signals and cross sectional images under maximum heat input both with and without the cover plate. To analyze the mechanical of weld properties, a hardness test analysis was conducted. To enhance the reliability of experimental results, temperature distributions were obtained using a simulation program. The method of inserting a cover plate led to a change in the heat input, which induced a larger nugget size between SGACEN and DP980.

포도, 배 재배용 과수봉지의 열화 특성 (Aging Characteristics of Grape and Pear Growth Paper Bag)

  • 하진양;채수명;윤승락
    • 펄프종이기술
    • /
    • 제46권6호
    • /
    • pp.41-49
    • /
    • 2014
  • The research was performed to investigate the weathering characteristics of fruit growth paper bags. The bags were used to cover fruits such as grapes and pears. And then they were collected after 30 and 60 days exposure at the orchard. The physical and optical properties of the bags tended to decrease with the exposure times. The larger change on the properties were found on the papers exposed for 30 days. The cover paper for pear showed the largest density changes. The air permeability were decreased with the exposure time in all bags. The cover paper for pear showed the very low values of air permeability. The mechanical properties of the fruit bags showed to be gradually decreased with the length of exposure time. The tear index showed the largest differences. The cover paper for pear showed the rapid decrease on the mechanical properties after 60 days of the exposure. The inner paper, however, showed the strength enough to cover the fruits. The precipitation showed more effect on the degradation of fruit growth paper bags than the light hours.

잠수함 마스트 커버의 구조해석 및 3D 프린팅 (3D Printing and Structure Anlaysis of the Submarine Mast Cover)

  • 우재혁;차병준;진철규
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.937-943
    • /
    • 2023
  • In this study, the mast cover of submarine was reverse engineered and structural analysis was performed. In order to print with the 3D printer, the modeling was reduced to 1/5 size by applying geometric similarity. From the structural analysis results, it was found that the maximum value of equivalent stress generated in the mast cover was 180.9 MPa. This stress value occurs on the inner surface in the major axis. As a result of applying the load condition at a diving depth of 600 m, the mast cover is in a completely elastic state. The 1/5 size model printed on FDM 3D printer with PLA filament was the same as the reverse engineered modeling and it was printed in a perfect shape with no apparent defects. The 1/5 size model printed on PBF 3D printer with SUS316L powder was perfectly manufactured with no apparent defects.

일중 피복온실의 관류열전달계수 산정 (Estimation of Overall Heat Transfer Coefficient for Single Layer Covering in Greenhouse)

  • 황영윤;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제22권2호
    • /
    • pp.108-115
    • /
    • 2013
  • 본 연구의 목적은 일중피복온실의 피복재에 대하여 우리나라 환경에 적합한 관류열전달계수를 산정하는 방법을 찾아내고 검증하여 다양한 온실조건 및 환경조건에서 관류열전달계수를 산정할 수 있는 모델을 제시하는 것이다. 온실내부 및 외부온도와 피복재 표면온도와의 상관관계를 분석한 결과 주간 및 야간 온도를 모두 고려하였을 때보다 야간온도만을 고려하였을 경우가 상관성이 훨씬 더 높은 것으로 나타났다. 피복재의 표면온도가 온실의 외부온도보다는 내부온도와 상관성이 더 높은 것으로 나타났다. 관류열전달계수를 산정하는데 사용된 5가지 종류의 대류 및 복사열전달계수 산정식을 비교한 결과 Kittas가 제안한 대류 및 복사열전달계수 산정식이 가장 적합한 것으로 나타났다. 피복재 표면온도의 측정값과 계산 값의 상관성을 분석한 결과 직선의 기울기는 1.009이고 절편은 0.001이며 결정계수가 0.98로 나타나 본 연구에서 제시된 관류열전달계수 산정모델이 신뢰성이 있음을 확인할 수 있었다. 온실내부로부터 피복재 내부표면으로 전달되는 열흐름량의 경우 모든 풍속구간에 대해 대류열전달량이 복사열전달량보다 더 컸으며 풍속이 증가할수록 그 차이가 증가하였다. 외부표면에서 손실되는 열흐름량의 경우 풍속이 낮을 때에는 대류열전달량에 비해 복사열전달량이 더 컸으나 풍속이 증가함에 따라 그 차이는 점점 줄어들어 풍속이 높을 때에는 대류열전달량이 더 커지는 것으로 나타났다. 피복재 외부 표면의 대류열전달량은 내부표면의 대류열전달량에 직선적으로 비례하여 증가하는 것으로 나타났다. 풍속이 증가함에 따라 관류열전달계수는 증가하고 피복재의 표면 온도는 감소하는 것을 확인할 수 있었고, 변화추세를 보면 관류열전달계수는 거듭제곱함수와 그리고 표면온도는 로그함수와 잘 일치하였다.

차량용 플라스틱 혼 커버의 사출성형 싸이클 타임 개선을 위한 냉각 채널의 수치해석 연구 (Numerical Analysis of Cooling Channels for Injection Molding Cycle Time Improvement of Plastic Horn Cover for an Automobile)

  • 한성렬
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.84-90
    • /
    • 2018
  • When producing a plastic horn cover for an automobile, since the interval between the ribs on the inner surface is narrow, conventional cooling channels cannot be applied and cooling of the mold is difficult. For this reason, the molding operation cannot be completed within a set cycle time. In this study, a conformal cooling channel was applied on the mold to solve the cooling problem. Injection molding simulation was carried out to confirm the effectiveness of the conformal cooling channel. In the analysis results, the mold temperature at the rib section decreased by 33%, and the mold temperature also decreased by 31%. This reduction in temperature allowed for molding within a set cycle time and demonstrated the effectiveness of the conformal cooling channel.

Three-Channel Output Multiplexer Design Using Band-Pass Filter and Ultra-Wideband Antenna

  • Lee, Jung Nam;Park, Jong Kweon
    • Journal of electromagnetic engineering and science
    • /
    • 제16권2호
    • /
    • pp.100-105
    • /
    • 2016
  • We have designed a three-channel output multiplexer (OMUX) using a band-pass filter and an ultra-wideband (UWB) antenna. The proposed band-pass filter is composed of an inner rectangular loop, an outer open stub, and a defected ground structure. The outer open stub can be used to control the pass band, and the inner rectangular loop can improve the insertion loss characteristics of the band-pass filter. The proposed band-pass filter, UWB antenna, and OMUX are fabricated and measured. The designed OMUX can cover the band group 1 (3,168-4,752 MHz) of WiX system. The measured radiation patterns are close to those of a conventional dipole antenna and the measured antenna gain varies from 1.8 dBi to 3 dBi over the operating frequency range.

건설 현장 항타 하중에 의한 지중 삼중관 진동 거동 II. 매설 심도 (Dynamic Response of Underground Three-layered Pipeline Subjected to Pile Driving Loads : II. Cover Depth)

  • 유한규;원종화;최정현;김문겸
    • 한국가스학회지
    • /
    • 제15권4호
    • /
    • pp.15-20
    • /
    • 2011
  • 본 연구는 매설 조건이 불건전한 건설 현장에 매설된 삼중관이 항타 진동에 노출되었을 경우에 발생하는 배관의 거동을 매설 심도에 따라 분석하였다. 매설 배관으로부터 20m의 이격 거리를 갖는 항타 에너지는 7tonf의 램이 1.2m에서 낙하하였을 경우로 선정하였고, 매설 심도는 0.6, 1.4, 2.2, 3.0, 3.8m로 변화하여 연구를 진행하였다. 관의 길이방향 중심에서의 진동 속도와 응력을 확인 하였고, 감쇠비를 고려하여 삼중관의 거동을 분석하였다. 이격거리가 동일한 경우의 진동 속도에 대한 감쇠율은 매설 심도가 증가함에 따라 증가하는 추세를 보이고 있다. 또한, 내관에서 응력 감쇠율도 매설 심도가 증가함에 따라 증가하는 추세를 보이고 있다.

콘크리트 믹서 트럭 덮개의 유무가 콘크리트 품질 특성에 미치는 영향에 관한 기초연구 (A Fundamental Study on the Influence of Fresh Concrete Quality Properties due to the Cover of Concrete Mixer Truck)

  • 채영석;임병훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.198-204
    • /
    • 2010
  • 콘크리트 믹서트럭의 덮개는 레미콘 플랜트에서 공사 현장까지의 운반 도중 굳지 않은 콘크리트의 유동성이 저하하지 않도록 사용하는데, 설문 결과 일반시민들에게 더러운 이미지를 주고 있다. 이러한 이미지로 인해 건설 산업 전체의 이미지에도 영향을 미칠 것으로 예상하여 덮개의 효용성 여부를 밝히기 위해 레미콘을 현장에 대기시켜 둔 채 유동성을 비롯한 공기량, 콘크리트 온도변화 등의 현장 실험을 실시하였다. 또한 이와 비교를 위해 동일한 조건으로 실내 실험을 병행하여 결과를 도출하였다. 실험 결과, 믹서트럭의 덮개는 슬럼프 저하에 미치는 영향이 적은 것으로 나타났다. 공기량 변화는 덮개 유무에 관계없이 60분까지는 적정한 수준으로 품질에 큰 영향을 미치지 않는 것으로 나타났다. 또한 콘크리트 압축강도는 덮개 유무에 관계없이 90분까지의 시료의 경우에 목표설계기준강도에 모두 적합한 것으로 나타났다.

소듐냉각 고속로의 커버가스 영역에서 열유동 해석 (ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN THE COVER GAS REGION OF SODIUM-COOLED FAST REACTOR)

  • 이태호;김성오;한도희
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.21-27
    • /
    • 2008
  • The reactor head of a sodium-cooled fast reactor KALIMER-600 should be cooled during the reactor operation in order to maintain the integrity of sealing material and to prevent a creep fatigue. Analyzing turbulent natural convection flow in the cover gas region of reactor vessel with the commercial CFD code CFX10.0, the cooling requirement for the reactor head and the performance of the insulation plate were assessed. The results showed that the high temperature region around reactor vessel was caused by the convective heat transfer of Helium gas flow ascending the gap between the insulation plate and the reactor vessel inner wall. The insulation plate was shown to sufficiently block the radiative heat transfer from pool surface to reactor head to a satisfactory degree. More than $32.5m^3$/sec of cooling air flow rate was predicted to maintain the required temperature of reactor head.

Modeling cover cracking due to rebar corrosion in RC members

  • Allampallewar, Satish B.;Srividya, A.
    • Structural Engineering and Mechanics
    • /
    • 제30권6호
    • /
    • pp.713-732
    • /
    • 2008
  • Serviceability and durability of the concrete members can be seriously affected by the corrosion of steel rebar. Carbonation front and or chloride ingress can destroy the passive film on rebar and may set the corrosion (oxidation process). Depending on the level of oxidation (expansive corrosion products/rust) damage to the cover concrete takes place in the form of expansion, cracking and spalling or delamination. This makes the concrete unable to develop forces through bond and also become unprotected against further degradation from corrosion; and thus marks the end of service life for corrosion-affected structures. This paper presents an analytical model that predicts the weight loss of steel rebar and the corresponding time from onset of corrosion for the known corrosion rate and thus can be used for the determination of time to cover cracking in corrosion affected RC member. This model uses fully the thick-walled cylinder approach. The gradual crack propagation in radial directions (from inside) is considered when the circumferential tensile stresses at the inner surface of intact concrete have reached the tensile strength of concrete. The analysis is done separately with and without considering the stiffness of reinforcing steel and rust combine along with the assumption of zero residual strength of cracked concrete. The model accounts for the time required for corrosion products to fill a porous zone before they start inducing expansive pressure on the concrete surrounding the steel rebar. The capability of the model to produce the experimental trends is demonstrated by comparing the model's predictions with the results of experimental data published in the literature. The effect of considering the corroded reinforcing steel bar stiffness is demonstrated. A sensitivity analysis has also been carried out to show the influence of the various parameters. It has been found that material properties and their inter-relations significantly influence weight loss of rebar. Time to cover cracking from onset of corrosion for the same weight loss is influenced by corrosion rate and state of oxidation of corrosion product formed. Time to cover cracking from onset of corrosion is useful in making certain decisions pertaining to inspection, repair, rehabilitation, replacement and demolition of RC member/structure in corrosive environment.