• Title/Summary/Keyword: Inner Wall

Search Result 701, Processing Time 0.031 seconds

Selection of Heater Location in Linear Source for OLED Vapor Deposition (OLED 증착을 위한 선형증발원 히터 위치선정)

  • Joo, Young-Cheol;Han, Choong-Hwan;Um, Tai-Joon;Lee, Sang-Wook;Kim, Kug-Weon;Kwon, Kye-Si
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.515-518
    • /
    • 2008
  • Organic light emitting diode(OLED) is one of the most promising type of future flat panel display. A linear source is used to deposite organic vapor to a large size OLED substrate. An electric heater which is attached on the side of linear source heats the organic powder for the sublimation. The nozzle of heater, which is attached at the top of the linear source has an optimal temperature. An numerical analysis has been performed to find optimal heater position for the optimal nozzle temperature. A commercial CFD program, FLUENT, is used on the analysis. Two-dimensional and three-dimensional analysis have been performed. The analysis showed that the heater should be attached at the outer side of crucible wall rather than inner side of housing, which was original design. Eighteen milimeter from the top of the linear source was suggested as the optimal position of heater. Improving thermal performance of linear source not only helps the uniformity of organic vapor deposition on the substrate but also increase productibity of vapor deposition process.

A Case Study on Using Interactive Media of Large Space Structure (대공간구조물의 Interactive Media 적용 사례 분석)

  • Kim, Sic;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2011
  • Interactive media are applied to inner and outer space of small public space to enhance for the interaction between the spectator and works, also widely used in the exterior wall by LED and projector for advertisement. In the other hand, case studies of interactive media for large space have not less accomplished than those of buildings and public spaces. Thus, these studies analyzed 11 large structure examples by display, content, interface, and technology device by comparison of those cases of ordinary building public space. First interactive media for large space are found to be contents(39%), and next one is play(27%), advertisement(17%) and message(17%).

The Analysis of Inground LNG Storage Tank Compression Ring Behavior during Concrete Pouring (콘크리트 타설에 따른 지하식 LNG 저장탱크 컴프레션링 거동 분석)

  • Kim Y.K.;Kim J.H.;Yoon I.S.;Oh B.T.;Yang Y.M.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.16-21
    • /
    • 2005
  • Functions of the compression ring plate fixed at the concrete side wall are to connect and support the steel roof plate. It should be designed to endure stably all the loads such as weight of steel roof, inner pressure and concrete weight. Behavior of the compression ring during construction has been analyzed by the finite element method and real measured data. Additionally, on the basis of results from parametric study of design variables for the steel roof a more reasonable design method for the compression ring has been proposed.

  • PDF

A new configuration in a prosthetic knee using of hybrid concept of an MR brake with a T-shaped drum incorporating an arc form surface

  • Sayyaadi, Hassan;Zareh, Seiyed Hamid
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.275-296
    • /
    • 2016
  • This paper focuses on developing a new configuration on magnetorheological (MR) brake damper as prosthetic knee. Prosthetic knee uses magnetic fields to vary the viscosity of the MR fluid, and thereby its flexion resistance. Exerted transmissibility torque of the knee greatly depends on the magnetic field intensity in the MR fluid. In this study a rotary damper using MR fluid is addressed in which a single rotary disc will act as a brake while MR fluid is activated by magnetic field in different walking gait. The main objective of this study is to investigate a prosthetic knee with one activating rotary disc to accomplish necessary braking torque in walking gait via T-shaped drum with arc surface boundary and implementing of Newton's equation of motion to derive generated torque at the inner surface of the rotary drum. For this purpose a novel configuration of a T-shaped drum based on the effects of a material deformation process is proposed. In this new design, the T-shaped disc will increase the effective areas of influences in between drum and MR fluid together and the arc wall crushes the particles chains (fibrils) of the MR fluid together instead of breaking them via strain in a conventional MR brake. To verify the proposed MR brake, results of the proposed and conventional MR brakes are compared together and demonstrated that the resisting torque of the proposed MR brake is almost two times greater than that of the conventional brake.

A new method to estimate rheological properties of lubricating layer for prediction of concrete pumping

  • Jang, Kyong Pil;Kim, Woo Jae;Choi, Myoung Sung;Kwon, Seung Hee
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.465-483
    • /
    • 2018
  • The most crucial factor determining the pumping performance of concrete is the characteristics of the lubricating layer formed between the pipe wall and the inner concrete. Thus, it is important to accurately identify the rheological properties of the lubricating layer to predict the pumping of concrete. In this study, a new method is proposed for measuring the rheological properties of the lubricating layer with improved convenience. To verify the new method, a pumping test was conducted with 337 m-long horizontal piping. The rheological properties of the lubricating layer were assessed by a previously verified method and the new method proposed in this study for a total of four concrete mixtures with design strength ranging from 27 MPa to 60 MPa. The correlation between the existing method and the new method in relation to the viscosity of the lubricating layer was determined, and it was possible to predict the pumping performance with an accuracy of about 88.5% using the viscosity of the lubricating layer obtained from this correlation.

Void Fraction Measurement by the Improved Multi-Channel Impedance Void Meter (개량된 다채널 임피던스형 측정기에 의한 기포율의 측정)

  • Song, Cheol-Hwa;Jeong, Mun-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.384-398
    • /
    • 1996
  • An improved multi-channel Impedance Void Meter (IVM) is developed to measure an area-averaged void fraction. It consists of a main sensor, a reference sensor and a signal processor. The sensor was designed to be flush-mounted to the inner wall of the test section to avoid the flow disturbances. Guard electrodes are used to obtain evenly distributed electrical field in a measuring volume. A reference sensor is also installed to eliminate the drift in void signal caused by the changes in electrical properties of working fluid. The signal processor with three channels is specially designed so as to minimize the inherent error due to the phase difference between channels. As an example of applications, the mean and fluctuating components of void fraction are measured for bubbly and slug flow regime, and it is shown that IVM has good dynamic resolution which is required to investigate the structural developments of bubbly flow and the propagation of void waves in a flow channel.

A Study on the Solar Distillation in a Cube with Tilted Angles (경사진 육면체에서의 태양열에 의한 증발 현상에 대한 연구)

  • Park, Yeong-Hoon;Kim, Byung-Chul
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1424-1429
    • /
    • 2004
  • Distillation is one of many processes that can be used for the purification of water. It requires an energy input such as heat and solar radiation is a possible source of energy. In this process, water is evaporated, thus separating water vapor from the solute. The vapor is then condensed to pure water. The temperature of the water, the cavity of the enclosure and the surface of the glass was measured everyday. Fifteen points were chosen for the temperature measure using a thermocouple. The inner wall and the bottom of each still was painted black for good absorption of heat. The enforced glass was used for the cover for the entering of solar energy. The size of all of the water baths was the same, but the glass of the rectangular form had a tilted angle. In the case of fine or general weather, the volume of condensed water produced by $45^{\circ}$ and $60^{\circ}$ is very irregular compared to that of $15^{\circ}$ and $30^{\circ}$, In case of a rainy day, the occurrence of the volume of condensed water was similar to that of $15^{\circ}$ and $30^{\circ}$, but the volume of condensed water produced by $30^{\circ}$ was the highest.

  • PDF

Ways of Remodeling from the Traditional Hanok to the Modern Local Governmental Facility in 1910s - Focused on Architectural Drawings of the National Archives of Korea - (1910년대 근대적 지방관립시설로 사용된 한옥의 개조 방식 -국가기록원 소장 건축 도면의 분석을 통하여-)

  • Joo, Sang-Hun
    • Journal of architectural history
    • /
    • v.24 no.1
    • /
    • pp.7-16
    • /
    • 2015
  • The purpose of this study is to identify ways of remodeling from the traditional hanok to the modern local governmental facility in 1910s. Analysing architectural drawings in the National Archives of Korea, 58 hanok remodeling cases of 52 facilities were verified like the provincial office, county office, county court from 1907 to 1910s. Using hanok as the local governmental building, exterior walls were all changed to the scaled-wooden wall like one of western-wooden building in 1910s and the western-style entrance was set. Change of the plan caused by remodeling interior walls had an intention of the centralized closed plan. Remodeled semi-outer corridor using the space of the eave became changed to the inner corridor with expansion of space. Expansion of hanok for spatial demand was in three ways. First was the expansion towards the eave space, second was direct extension from hanok, and last was the use of external corridor to the new building. Using the eave space was simple but had limitation of space, it was planed with other expansion ways. The way of direct extension was usually used than the one with the corridor, because it was more economical way.

Thrust Performances of a Very Low-Power Micro-Arcjet

  • Hotaka Ashiya;Tsuyoshi Noda;Hideyuki Horisawa;Kim, Itsuro ura
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.611-616
    • /
    • 2004
  • In this study, microfabrication of a micro-arcjet nozzle with Fifth-harmonic generation Nd:YAG pulses (wavelength 213 nm) and its thrust performance tests were conducted. A micro-arcjet nozzle was machined in a 1.2 mm thick quartz plate. Sizes of the nozzle were 0.44 mm in width of the nozzle exit and constrictor diameter of 0.1 mm. For an anode, a thin film of Au (~100 nm thick) was deposited by DC discharge PVD in vacuum on divergent part of the nozzle. As for a cathode, an Au film was also coated on inner wall surface. In operational tests, a stable discharge was observed for mass flow of 1.0mg/sec, discharge current of 6 ㎃, discharge voltage of 600 V, or 3.6 W input power (specific power of 3.6 MW/kg). In this case, plenum pressure of the discharge chamber was 80 ㎪. With 3.6 W input power, thrust obtained was 1.4 mN giving specific impulse of 138 sec with thrust efficiency of 24 %.

  • PDF

An Experimental Study on the Characteristics of Evaporative Heat Transfer of Carbon Dioxide (이산화탄소의 증발열전달 특성에 관한 실험적 연구)

  • 조은석;윤석호;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.38-45
    • /
    • 2002
  • Evaporative heat transfer characteristics of carbon dioxide have been investi- gated by experiment. The experiments have been carried out for a seamless stainless steel tube of the outer diameter of 9.55 mm, the inner diameter of 7.75 mm and the length of 5.0 m. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Experiments were conducted with$CO_2$of purity 99.99% at saturation temperatures of 0.0 to 10.5$^{\circ}C$, heat fluxes of 12 to 27kW/$m^2$s and mass fluxes of 212 to 530 kg/$m^2$s. The heat transfer coefficients of $CO_2$are decreased as the vapor quality increases and these phenomena are explained by dimensionless Weber and Bond numbers. The heat transfer coefficients of$CO_2$increase when the heat and mass fluxes increase, and the saturation temperature effects are minor in the test range of this study. The present experimental data are compared with six renowned correlations with root-mean-squared deviations ranging from 23.0 to 94.9% respectively.