• Title/Summary/Keyword: Inner Tank

Search Result 166, Processing Time 0.02 seconds

Structural Analysis for Design of Anchor Straps for a Large-Scale LNG Storage Tank with Corner Protection and Inner Tank (코너프로텍션과 내조를 고려한 대용량 LNG 저장탱크 앵커스트랩의 구조설계를 위한 유한요소해석)

  • Jin, Chengzhu;Ha, Sung-Kyu;Kim, Seong-Jong;Lee, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1543-1548
    • /
    • 2011
  • Structural analysis is performed to design anchor straps for a large-scale-liquefied-natural-gas (LNG) storage tank with corner protection and an inner tank by considering structural integrity. Anchor straps made of 9% nickel steel are attached to the inner tank, corner protection, and concrete raft to prevent the failure of the inner tank during both normal and emergency operating conditions. Two finite element (FE) models were analyzed in this study. One is a stand-alone model of the anchor strap, while the other is an extended model of the substructure of the anchor strap, inner tank, and corner protection. Three-dimensional shell elements are used to effectively assess the bending and axial behavior of structures. The Tresca stress values in each part of the two models are calculated for operation under five different load-condition cases: normal operation, leakage of the LNG, hydro test, and two earthquake conditions.

Numerical Study on the Design Safety of $9\%$ Nickel Based Inner Tank Bottom Plate in Terms of Hydrostatic Pressure (유체정압을 고려한 $9\%$ 니켈강재 내부탱크 바닥판의 설계 안정성에 관한 수치적 연구)

  • Kim Chung Kyun;Kim Han Goo
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.35-41
    • /
    • 2004
  • This paper presents the stress and deformation characteristics of $9\%$ nickel based inner tank bottom plate in full containment LNG storage tank. When a . maximum hydrostatic pressure applies the bottom plate of inner tank, the maximum = f stress and displacement distributions of the bottom plate have been analyzed as ' functions of inclined angle of the bottom plate, and the thickness and length of the annular plate between the shell plate and bottom one. The calculated results indicate that the taper of the bottom plate is recommended by 100${\~}$200 : 1 for $140,000m^3$ storage capacity of the inner tank. The results recommend that the thickness of the annular plate is around 20mm and the length is greater than 3m for a maximum hydrostatic pressure of $140,000m^3$ tank capacity.

  • PDF

A Study on the Strength Safety of the Prestressed Concrete Outer Tank for a Membrane LNG Storage Tank (멤브레인식 LNG 저장탱크용 PC 외부탱크의 강도안전성에 관한 연구)

  • Kim, Chung-Kyun;Kim, Do-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2009
  • This paper presents the numerical study on the strength safety of the prestressed concrete outer tank for a LNG storage tank, which is manufactured by sets of membrane panels with special corrugations. This study for a finite element analysis assumes that the membrane panel of the inner tank was fractured and the liquefied natural gas stored in the inner membrane tank was leaked to the prestressed concrete outer tank. The stress and displacement of the outer tank have been analyzed for five different loadings, which are originated by a hydrostatic pressure and a weight of a LNG, a temperature difference, a weight of the prestressed concrete and a boil-off gas pressure. The computed FEM results indicate that the PC outer tank with a storage capacity of 200,000$m^3$ has a good strength safety for a leaked LNG from the membrane inner tank, but the increased cryogenic loadings in which are originated by a leaked LNG decreases the strength safety of the PC structure. This may lead to the collapse of the outer storage tank.

  • PDF

FE Analysis on the Design Safety of Inner Tank Bottom Plate in Terms of Cryogenic Temperature Loadings (초저온 하중을 고려한 내부탱크 바닥판의 설계 안정성에 관한 유한요소해석)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.8-15
    • /
    • 2004
  • This paper presents von Mises stress, deformation, and rotating distortion moment characteristics of inner tank bottom plate as a function of a cryogenic temperature difference along the radial distance from the center area to the corner one. The calculated results show that the filling level of LNG at the beginning of the cool-down process is very important for the design safety analysis of the inner tank. Obviously the thermal loading by a temperature difference between the LNG vapor gas of $-80^{\circ}C$ and a LNG temperature of $-162^{\circ}C$ affects to the thermal related characteristics of the bottom plates and annular one. From the computed results, the temperature difference by a vapor gas and liquid of LNG may lead to the thermal instability of the bottom plate. This phenomenon may cause the system failure of an inner tank.

  • PDF

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.

A Study on the Leak-Proof of Full Containment Type Prestressed Concrete Structure (완전 밀폐형 PC 구조물의 누설 안전성에 관한 연구)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.85-91
    • /
    • 2001
  • This paper presents safety analysis of LNG leakage in a prestressed concrete outer tank, which is strongly related on the leak checking effects of the PC structure with and without a residual compression zone based on the BS 7777 codes. The full containment type outer tank which is constructed by a prestressed concrete may be destroyed by leaked cryogenic fluids. The FE calculated results show that the total leak checking time of the PC structure with $10\%$ residual compression zone is about 9 days for $-162^{\circ}C$ liquids. But, three primary pumps in an inner tank may operate to send cryogenic fluids for 6 days, which are stored in an inner tank of $140,000m^3$ capacity This means that the prestressed concrete outer tank may be safe for $-162^{\circ}C$ cryogenic fluids leaked from the demolished inner tank.

  • PDF

Integrity comparison for various design specifications of corner protections in LNG storage tank (LNG저장탱크 코너프로텍션의 설계사양에 따른 건전성 비교)

  • Kim Hyoungsik;Hong Seongho;Seo Heungseok
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.33-39
    • /
    • 2002
  • [ $9\%$ ] nickel steel LNG storage tank have double containments that can store cryogenic LNG independently. Inner tank material is used as $9\%$ nickel steel and outer tank is constructed by concrete. Comer protection which is installed on inner surface of concrete corner is consist of $9\%$ nickel steel liner and form glass insulator that make reduce tension at corner when LNG is leaked from inner tank. It is very difficult to design corner protection because expansion and contraction of liner make stress state complex. Corner protections of operating tank in KOGAS are designed by Japanese engineering company such as TKK, KHI and England company of WHESSOE. This paper is mainly focused on the integrity comparison of them according to requirements of Appendix 4 in ASME Section VIII Div. 2 by using FEM.

  • PDF

Advanced Heat Transfer Analysis Model of LNG Storage Tank (LNG 저장탱크의 개선된 온도해석 모델)

  • 전세진;정철헌;진병무;김성운
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.115-120
    • /
    • 2003
  • Several methodologies were devised to reasonably predict the temperature boundary conditions of inner face of the concrete outer tank so as to set up heat transfer analysis model of the full containment above-ground LNG storage tank. In this model, outer tank is solely taken into account and the beneficial effect of suspended deck and insulation layers on the temperature distribution of outer tank is separately formulated according to the proposed procedures. More effective design of the insulations can be achieved when the proposed simple schemes are used in the preliminary stage.

  • PDF

Feasibility study on the wide and long 9%Ni steel plate for use in the LNG storage inner tank shell

  • Chung, Myungjin;Kim, Jongmin;Kim, Jin-Kook
    • Steel and Composite Structures
    • /
    • v.32 no.5
    • /
    • pp.571-582
    • /
    • 2019
  • This study aimed to assess the feasibility on the wide and long 9%Ni steel plate for use in the LNG storage inner tank shell. First, 5-m-wide and 15-m-long 9%Ni steel plates were test manufactured from a steel mill and specimens taken from the plates were tested for strength, toughness, and flatness to verify their performance based on international standards and design specifications. Second, plates with a thickness of 10 mm and 25 mm, a width of 4.8~5.0 m, and a length of 15 m were test fabricated by subjecting to pretreatment, beveling, and roll bending resulting in a final width of 4.5~4.8 m and a length of 14.8m with fabrication errors identical to conventional plates. Third, welded specimens obtained via shield metal arc welding used for vertical welding of inner tank shell and submerged arc welding used for horizontal welding were also tested for strength, toughness and ductility. Fourth, verification of shell plate material and fabrication was followed by test erection using two 25-mm-thick, 4.5-m-wide and 14.8-m-long 9%Ni steel plates. No undesirable welding failure or deformation was found. Finally, parametric design using wide and long 9%Ni steel plates was carried out, and a simplified design method to determine the plate thickness along the shell height was proposed. The cost analysis based on the parametric design resulted in about 2% increase of steel weight; however, the construction cost was reduced about 6% due to large reduction in welding work.

Numerical Analysis on the Stress and Deformation Characteristics of LNG Membrane Storage Tank System with Corner Protection (코너프로텍션 설치에 따른 멤브레인 LNG 저장탱크 시스템의 응력 및 변형거동 특성에 관한 수치해석)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.9-14
    • /
    • 2009
  • In this study, the stress and deformation characteristics of corner protection in which is fabricated in an insulation area have been analyzed using a finite element method. The proposed corner protection may increase the strength and leakage safeties of conventional LNG storage system. The stress and deformation of LNG storage tank system are computed for an insulation panel box, membrane inner tank, and prestressed concrete outer tank. The FEM computed results indicate that the stress and displacement of new membrane LNG tank system with a corner protection between an inner tank and an outer tank are reduced in comparison to those of a conventional membrane LNG tank. This is explained that the strength safety of LNG membrane tank system may be increased due to a strength stiffness of a corner protection.

  • PDF