• Title/Summary/Keyword: Inner Case

Search Result 1,043, Processing Time 0.03 seconds

Three-Dimensional Thermoforming Analysis of an Inner Case with Three Cavities for Refrigerator (3개의 캐비티를 가지는 냉장고 내상의 3차원 진공 열성형 해석)

  • Lee, Ho Jin;Ahn, Dong Gyu;Lee, Sang Hun;Ki, Jun Chul;Ko, Jae Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.5
    • /
    • pp.505-511
    • /
    • 2016
  • The aim of this study is to investigate the thermoforming characteristics of an inner case with three refrigerator cavities using three-dimensional(3D) thermoforming analyses. We perform fundamental formability analyses using a 3D model of the mould for the inner case. We carry out tensile tests at the elevated temperature to examine the properties and characteristics of the thermoformed material. Then, we design sub-processes of the thermoforming process for the inner case. In addition, we develop suitable finite-element models for different sub-processes. We investigate the deformed shapes and thickness distributions of the inner case for different sub-processes using the results of the thermoforming analysis. Finally, we discuss the formability and thermoforming characteristics of the inner case with three cavities.

Study on Effective Case Depth for Case Hardened Rolling Bearings (탄소 표면경화처리 구름베어링의 유효 경화 깊이에 대한 고찰)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.32 no.1
    • /
    • pp.18-23
    • /
    • 2016
  • The effective case depth for case-hardened rolling bearing has been discussed. For this purpose, rolling contact fatigue tests for ball bearings built with inner race of various hardness values were conducted until L10 calculating rating life using a bearing life test machine under radial loading. Then, the distribution of residual stress below the inner raceway, which depended on the hardness value, was measured by X-ray diffraction. As a result, the linear relationship was established between the hardness value of the inner race and the theoretical shear stress evaluated at the depth where the residual stress disappeared below the inner raceway. Based on the relationship, it could be found that the factor of safety in bearing manufacturer’s rules for the effective case depth of case hardened rolling bearings was set higher. However, it could be also found that the hardness values at the depth where the maximum shearing stress acted below the raceway surface in a tapered roller bearing hardened by the carburizing process, were not sufficient for preventing plastic deformation under the basic dynamic load rating. Consequently, further efforts were still required to reduce or to disperse the contact load on the material design of a rolling bearing in order to prolong its life.

A Study on Planning Guideline of Complex Housing in the Residence Inner Area - Case Study of Inner Area in Iksan City - (도심주거지의 주상복합주택 계획지침에 관한 연구 - 익산시 구도심을 사례로 -)

  • Kim, Young-Seok;Park, Pyung-Youl
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.173-179
    • /
    • 2003
  • This study analyzes the problems, which the residential inner area has, and proposes systematic and gradual progressing improvement plan for the residential environment in the inner area. Also, planning instruction is proposed through the case study of parcel·jointed complex housing. This study can be concluded as below: (1) Improvement plans sub-divided into promoting districts and inducing districts of the residential inner area are proposed. (2) Necessity for construction of streets is proposed in order to compensate existing problems in sites. (3) Necessity of complex housings is proposed fur roadsides of household unit or small-sized annexation of parcel. (4) Collecting design examples and existing literatures, the planning guideline for jointed parcel complex housing is proposed based on the established relation with a whole surface of streets, formation and distribution of purposes and increased role of exterior space.

  • PDF

A Study on Fatigue Behavior according to Effective Case Depth in Induction Case Hardened SM45C Steel (고주파표면경화한 SM45C 강에서 유교경화층깊이가 피로거동에 미치는 영향)

  • 오세욱;호정원;박원조
    • Journal of Ocean Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.71-80
    • /
    • 1991
  • This paper reveals the effect of the effective case depth(ECD) on the fatigue behavior of a high-frequency induction hardened SM45C in rotated bending fatigue test. In addition, the effects of fracture modes(surface origin type, inner origin type) on it are discussed. The fatigue limit of the induction hardened steel is remarkably increased compared with that of base metal. In addition, the fatigue limit is linearly increased as the effective casedepth grows deep in the region of this experiment (ECD/R;0.23-0.49). The S-N curve and fracture mode in the induction case hardened steel are classified into two kinds, as a result : N$_{f}$<10$^{5}$ ;surface origin type fracture(at high stress), N$_{f}$>10$^{5}$ ; in ner origin type fracture(at low stress). In case of inner origin type fracture; as the effective case depth(ECD) gets deep, the fatigue limit is increased by the reason that the fracture origin moves toward center; in reverse, is decreased by reason that the compressive residual stress gets low. As a result, the increasing effect of the former is much bigger than the decreasing effect of the latter, and the fatigue limit is increased as the ECD gets deep.eep.

  • PDF

The Effects of Construction of Tipping Paper and Plug Wrap Permeability on the Dual Cigarette Filter Ventilation (팁페이파 및 필터권지 기공도 조합이 이중필터 제품담배 공기희석율에 미치는 영향)

  • 김정열;김종열;신창호
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.24 no.2
    • /
    • pp.107-112
    • /
    • 2002
  • There are many combination with the porosity of tipping paper and plug wrap for a design of ventilation rate of cigarette. This study was carried out to determine the effect of a design of permeability of tipping paper and inner or outer of plug wrap on the ventilation rate of cigarette with constant pressure drop in column part and filter part. Our results indicated that the higher the plugwrap porosity, the higher the ventilation rate and the less variable of cigarette in case of mono filter. But, in case of duel filter, the ventilation rate of cigarette was depended on the manufacturing method of filter plug, even though using the same porous plug wrap on inner and outer of filter. We also found that the porosity of outer plug wrap was more effect on the ventilation rate than the porosity of inner plug wrap. As the high porosity of inner plug wrap compared with the porosity of outer plug wrap, the less variable of ventilation rate of cigarette in any combination of the porosity of plug wrap. When we used the higher porous outer plug wrap than inner plug wrap, the ventilation rate of cigarette was high. Also, the higher the inner plug wrap porosity, the less variable of ventilation rate of cigarette.

An Analysis on Volumetric Displacement of Gerotor Pump/Motor Using Vane Length (회전날개 길이를 이용한 제로터 펌프/모터의 배제용적에 관한 연구)

  • Kim, S.D.;Kim, D.M.;Ham, Y.B.;Han, C.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.8-16
    • /
    • 2011
  • It is hard and complicated to analytically derive the volumetric-displacement formula of a gerotor pump/motor. Analytical formulas for calculating the volumetric-displacement are derived in this work, which is relatively easy and based upon vane lengths. The vane lengths mean the distances from axis of inner rotor or outer rotor to contact points between inner and outer rotors. Two kinds of formula were studied for two different kinematic motions of rotors. The first one is the case that outer rotor is fixed in space and inner rotor is in mixed motion of planetary revolution and rotation with respect to the spinning axis. And the second is the case that both inner and outer rotors simultaneously rotate. The proposed formula is verified through comparison with volumetric-displacement obtained from numerical CAD calculation.

A Study on the Reduction of Entry Loss by Inner Structure in Square Hood in Industrial Ventilation System (산업환기시설에서 사각형 후드의 내부 설치에 의한 유입손실 감소에 관한 연구)

  • Bae, Hyun-Joo;Yang, Won-Ho;Kim, Jong-Oh;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.27-34
    • /
    • 2003
  • An objective of local exhaust hood design is to design the hood to operate as efficiently as possible. The greatest loss normally occurs at the entrance to the duct, due to the vena contracta in the throat of the duct. This can be accomplished by minimizing the loss that results from the vena contracta. There have been little studied to be cost-effective approach as installing simple instrument inside the throat of the hood. The aims of this paper were to minimize entry loss using inner square, and to measure the effect of inner square when installed inside hood throat. The results of this study were as follows; First, the magnitude of vena contracta could be considered as the difference between direct measured velocity and calculated velocity, which is from Bernoulli theory. In circle hood, calculated velocity and direct measured velocity were 10.7m/sec and 10.3n/sec, respectively. And the calculated velocity and direct measured velocity in square hood were 7.7m./sec and 6.5m/sec, respectively. Second, effect of inner square by width was carried out. The widths of inner square were L/1(18cm), L/2(9cm), L/3(6cm) and L/6(3cm). In case inner square was installed with 3cm width, the entry of coefficient was 0.93, comparing with 0.85 of entry of coefficient of general hood. Third, effect of inner square by distance from hood inside surface to inner square was carried out. The distances were L/3(6cm), L/6(3cm), L/9(2cm) and L/l8(1cm). In case the distance was 3cm the best efficiency was shown (Ce= 0.93). Fourth, effect of inner square by location from hood entry to duct inside was carried out. The locations of inner square were entry(0cm), L/6(3cm), L/3(6cm), L/2(9cm) and L/l(12cm). In case the location was 0cm, 3cm and 6cm the entry of coefficients were 0.93, 0.92 and 0.90, respectively.

The Study for Bead Effect in Inner Case on Thermal Deformation of Refrigerator (냉장고 내벽의 비드가 열변형에 미치는 영향에 관한 연구)

  • Zhai, JianGuang;Cho, Jong-Rae;Jeon, Woo-Jin;Kim, Joo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.96-101
    • /
    • 2011
  • Under extreme test or operation condition, refrigerator endures complicated stresses state and thermal bowing deformation arises on the sidewall. Shelf rails designed in the inner case provide increased surface area to permit expansion without bowing, and also increase structural rigidity to resist bowing. In this study, we designed six different shelf patterns of refrigerator model and studied the bead on refrigerator deformation using finite element method (FEM). Analysis result shows that increasing the numbers of beads properly in refrigerator is more helpful to reduce thermal bowing deformation. In addition, the beads would decrease stress on refrigerator sidewall. However, vertical beads have no effect to reduce thermal deformation of the bowing.