• 제목/요약/키워드: Inlet pressure built-up

검색결과 8건 처리시간 0.032초

공기베어링에서의 선단압력발생에 관한 연구 (A Study on Inlet Pressure Build-up of Air-Lubricated Bearings)

  • 김성국;김경웅
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.127-132
    • /
    • 1999
  • The inlet pressure build-up at the leading edge of bearings which have discontinuous lubrication surface is analyzed theoretically. The analyses of Inlet pressure build-up is obtained by means of full Navier-stokes equations. Beam-warming method is used to solve navier-stokes equations. The results show that inlet pressure is above atmosphere pressure in front of leading edge of hearing.

  • PDF

충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구 (A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter)

  • 서정민;최금찬;박정호
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

세라믹 캔들 필터 주위의 분진 속도분포 측정 (Measurements of Dust Velocity Field around the Ceramic Candle Filter)

  • 고용서;정진도;김승태
    • 청정기술
    • /
    • 제5권1호
    • /
    • pp.30-41
    • /
    • 1999
  • 본 연구는 독일 Schumacher사의 1m 크기의 세라믹 캔들 필터가 1개 설치된 실험장치를 구성하여 집진시 단일 필터 주위에서의 분진 속도분포를 PDPA를 이용하여 측정하고, 분진층의 유무와 분진 투입 위치에 따른 분진 속도분포의 변화를 관찰하였다. 측정 결과 집진이 계속되어 필터 표면에 분진층이 발달함에 따라 집진 속도가 감소됨을 알 수 있었다. 특히, 투입구가 위치하는 필터표면에서 집중적으로 분진층이 발달하여 이곳에서의 분진 속도 감소가 크게 나타났다. 그리고 필터 내부와 압력용기부사이의 압력 차에 의한 필터 표면에서의 분진 속도 평균값은 0.28m/sec 이었다. 또한 분진 투입을 압력용기부 하단에 위치한 투입구로 투입하였을 때 필터 주위의 분진의 고른 속도분포를 관찰할 수 있었다.

  • PDF

화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 - (Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers -)

  • 김세훈;진정근;권세진
    • 대한기계학회논문집B
    • /
    • 제29권1호
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.

가스터빈엔진 고공성능시험설비의 측정불확도 개선 (Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines)

  • 이대성;양인영;전용민;김춘택;양수석
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

열공압형 마이크로 펌프의 제작에 관한 연구 (A Study on the Fabrication of a Thremopneumatic micropump)

  • 김영수;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1960-1962
    • /
    • 1996
  • A thermopneumatic micropump with two micronozzles has been fabricated and tested. The actuator consists of a p+ diaphragm and a pyrex glass on which a microheater is deposited. Two micronozzles are fabricated on either side of a single silicon wafer and behave as a dynamic passive valves. The actuator and the micronozzle are assembled to make a micropump. The center deflection of the actuator diaphragm to step voltage input has been measured. The dynamic test hag been performed by measuring the center deflection of the diaphragm under various input voltages and duty ratios. Also dynamic pumping test is performed. The measured built-up pressure between inlet and outlet of the micropump is 80 Pa for the actuation at 20V, 10 Hz.

  • PDF

용융아연도금설비의 gas wiping시 강판표면의 기체 유동해석 (Gas now Analysis Around Strip Edge During Gas Wiping for CGL)

  • 황원걸;성원석;김형;정진환;박노범
    • 한국표면공학회지
    • /
    • 제34권2호
    • /
    • pp.115-124
    • /
    • 2001
  • Gas wiping process of continuously hot-dip galvanized coating on steel strip has noise and coating problems. To improve the qualify of product, characteristics of air flow on the steel surface must be investigated. In this paper, fluid dynamic model of the gas flow is setup and solved numerically using STAR-CD. The effects of edge baffle, distance between steel plane edge and baffle, inlet pressure, and gap between air knife and strip steel surface are investigated, and it is concluded that edge baffle can reduce over-coating and edge built-up.

  • PDF

2 리터급 터보과급 가솔린 기관에서 내장형 WGV가 기관 성능에 미치는 영향 (The Effect of the Embedded WGV on the Engine Performance for a 2-liter Turbo-charged Gasoline Engine)

  • 장종관
    • 한국자동차공학회논문집
    • /
    • 제24권2호
    • /
    • pp.232-241
    • /
    • 2016
  • The turbocharger, to decrease the harmful exhaust gas(CO, HC and etc.) and $CO_2$ emission as well as the increase of the engine output, would be an useful method for engine downsizing. Therefore the thermal endurance of turbine blade, the lubrication of turbine shaft and the engine knock according to the supercharge of the inlet air, had been studied. And there had been much progress in these research tasks to be achieved a breakthrough. But a study on the built-in WGV of a gasoline engine for a passenger car which may effect on the engine performance, is few. In this paper, the effect of the embedded WGV on the engine performance was performed through the endurance test, which was conducted more than 300 hrs using the 4 stroke, 1998 cc, water-cooled engine. To sum up the major results, there were an abrasion in the area of the WGV head edge and the thermal deformation on the WGV head face, These phenomena led to reducing the boost pressure which caused the reduction in the volumetric efficiency of the engine. It resulted in decreasing the engine power gradually during the life cycle of the embedded WGV.