• Title/Summary/Keyword: Inlet Shape

Search Result 362, Processing Time 0.024 seconds

Analysis of Age-related Distribution of the Tracheal Diameter and Cross-sectional Area Among Koreans -Compuerized Tomographic Measurement- (한국인의 연령별 기관 내경 및 단면적 분포에 대한 분석 -흉부전산화단층촬영을 이용한 측정-)

  • Lee, Gun;Kim, Dae-Sik;Moon, Seung-Chul;Koo, Won-Mo;Yang, Jin-Young;Lee, Hyeon-Jae;Lim, Chang-Young;Han, Hyeon;Kim, Kwang-Ho;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.442-447
    • /
    • 1999
  • Introduction: Understanding the normal distribution of the tracheal diameter and crross- sectional area is one of the key elements in the management of various tracheal pathologies or tracheal reconstruction for the patients in growing age. However, data for Korean standard has been lacking. This study was designed to analyze retrospectively the distribution of tracheal diameter and cross-sectional area in young Koreans, which can afford fundamental data for the management of tracheal diseases. Material and Method: Of the patients who underwent computerized tomogram of the chest between May 1996 and August 1998, one hundred six young patients(age range: 0-20 years) were included. Patients with any conditions which might affect the tracheal cross-sectional area or diameter, such as tracheal disease, previous operation, mediastinal tumor, or obstructive lung disease were excluded from the study. Gender distribution was 69 males and 37 females. Tracheal diameters, anterior-posterior and transverse, were measured at the level of the thoracic inlet(level I) and the aortic arch(level II). Types of the trachea were divided into round, oval, or horseshoe shaped on cross-sectional view, and the dimension was calculated by using the equation of A=1/4$\pi$ab(A; area, $\pi$; 3.14, a; anterior-posterior diameter, b; transverse diameter). We analyzed the distribution of the diameter at each level and compared the cross-sectional area with respect to age and gender. A p-value lower than 0.05 wa considered significant. Result: The trachea of patients less than 5 years old were round in shape at both of level I and II, and no differences in cross-sectional area was observed between the levels(p=NS). As the age increased, the trachea become oval in shape at level I while it remained round in shape at level II(p=0.020). The tracheal diameter and cross-sectional area increased as the age increased with a linear correlation(r>0.9). In patients less than 5 years of age, female patients showed larger cross-sectional area than male patients (p=0.020), and it was reversed in patients older than 15 years of age(p=0.002). Conclusion: From the above results, we suggest chest computerized tomogram as a safe and reliable tool in measuring the tracheal diameter and cross-sectional area. We also provide the data as a standard for distribution of the tracheal diameter and cross-sectional area in young Korean population.

  • PDF

Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture (NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구)

  • Kim, Ji-Young;Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • This research aims todevelopa compression/absorption hybrid heat pump system using an $NH_3/H_2O$ as working fluid.The heatpump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a desorber, a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above $90^{\circ}C$ using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangementof the plate heat exchangers with regard tothe concentration and distribution at the inlet of the absorber.

An Experimental Study of the Turbulent Swirling Flow and Heat Transfer Downstream of an Abrupt Expansion in a Circulat Pipe with Uniform Heat Flux (급확대관내에서 류유선회유동의 열전달에 관한 연구)

  • 권기린;허종철
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.138-152
    • /
    • 1996
  • Many studies of heat transfer on the swirling flow or unswirled flow in a abrupt pipe expansion are widely carried out. The mechanism is not fully found evidently due to the instabilities of flow in a sudden change of the shape and appearance of turbulent shear layers in a recirculation region and secondary vortex near the corner. The purpose of this study is to obtain data through an experimental study of the swirling flow and heat transfer downstream of an abrupt expansion in a circular pipe with uniform heat flux. Experiments were carried out for the turbulent flow nd heat transfer downstream of an abrupt circular pipe expansion. The uniform heat flux condition was imposed to the downstream of the abrupt expansion by using an electrically heated pipe. Experimental data are presented for local heat transfer rates and local axial velocities in the tube downstream of an abrupt 3:1 & 2:1 expansion. Air was used as the working fluid in the upstream tube, the Reynolds number was varied from 60, 00 to 120, 000 and the swirl number range (based on the swirl chamber geometry, i.e. L/d ratio) in which the experiments were conducted were L/d=0, 8 and 16. Axial velocity increased rapidly at r/R=0.35 in the abrupt concentric expansion turbulent flow through the test tube in unswirled flow. It showed that with increasing axial distance the highest axial velocities move toward the tube wall in the case of the swirling flow abrupt expansion. A uniform wall heat flux boundary condition was employed, which resulted in wall-to-bulk temperatures ranging from 24.deg. C to 71.deg. C. In swirling flow, the wall temperature showed a greater increase at L/d=16 than any other L/d. The bulk temperature showed a minimum value at the pipe inlet, it also exhibited a linear increase with axial distance along the pipe. As swirl intensity increased, the location of peak Nu numbers was observed to shift from 4 to 1 step heights downstream of the expansion. This upstream movement of the maximum Nusselt number was accompanied by an increase in its magnitude from 2.2 to 8.8 times larger than fully developed tube flow values.

  • PDF

Distribution of Soil and Water Temperatures and their Relation to Rice Growth in a Cold Water Irrigated Paddy Land (냉수(冷水) 관개답(灌漑畓)에서의 수온 및 지온 분포(分布)와 수도(水稻) 생육(生育) 및 수량 반응)

  • Kim, Lee-Yul;Im, Jeong-Nam;Yea, Jong-Doo;Kim, Dong-Jin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.15 no.4
    • /
    • pp.221-225
    • /
    • 1982
  • Soil and water temperature were measured at different distances from the irrigation inlet of a Paddy land supplied with $16^{\circ}C$ water. The rice growth and yields of Nongbaek variety (Japonica) and Milyang 23 variety (Indica${\times}$Japonica)were interrelated with average soil and water temperature from tillering to heading stage. Water temperature was asymtotically increased to $21^{\circ}C$ as cold water forwarded, while the distribution of soil temperature showed linear shape with distance overall, water temperature was 1 to $2^{\circ}C$ higher than soil temperature. Cold soil and water temperature shorterned culm length and panicle exertion and retarded heading date resulting in yield reduction, Response of rice growth and yield to water temperature was apparently different between two varieties. Nongbaek variety produced no grains below $17^{\circ}C$, but it's reproductive growth was possible from 17 to $20^{\circ}C$. A normal yield could be obtained at $21^{\circ}C$. Comparatively, no reproductive growth of Milyang 23 variety was Possible even at $19^{\circ}C$.

  • PDF

Cavitation Analysis on Ship Seawater Pump Using CFD (CFD를 이용한 선박용 해수펌프의 공동현상에 대한 분석)

  • Kim, Bu-Gi;Kim, Hong-Ryeol;Yang, Chang-Jo;Kim, Jun-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.4
    • /
    • pp.400-406
    • /
    • 2017
  • The model used in this study was reversed to analyze the cause of excessive damage that occurred inside the rotating system and pipe system of a centrifugal-type seawater pump on a ship. For this purpose, internal flow analysis on a cooling seawater pump was performed using CFD. As a result, the shape and boundary conditions of the target pump were set by reverse engineering, and pump efficiency at a design operating point of $125m^3/h$ was calculated as 85.3 % with a head of 32.0 m. The maximum efficiency point of the target pump was estimated to be 86.2 % at $150m^3/h$, but this differed from the actual operating point. At $112.5m^3/h$, which was the lowest flow point, flow was unstable due to the characteristics of the low flow point and analysis convergence was not good. The purpose of this study was to clarify the cause of ongoing cavitation in seawater pumps and piping systems in operation. Future research will be needed to clarify causes for pipe systems in the future by performing calculations for the total piping system of an inlet and outlet, in addition to measuring the flow rate of each branch pipe.

Numerical Analysis on Shock Waves Influence Generated by Supersonic Jet Flow According to Working Fluids (작동유체에 따른 초음속 제트유동에 의해 생성되는 충격파 영향에 관한 수치해석)

  • Jung, Jong-Kil;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.510-517
    • /
    • 2016
  • Supersonic jet technology using high pressures has been popularly utilized in diverse industrial and engineering areas related to working fluids. In this study, to consider the effects of a shock wave caused by supersonic jet flow from a high pressure pipe, the SST turbulent flow model provided in the ANSYS FLUENT v.16 was applied and the flow characteristics of the pressure ratio and Mach number were analyzed in accordance with the working fluids (air, oxygen, and hydrogen). Before carrying out CFD (Computational Fluid Dynamics) analysis, it was presumed that the inlet gas temperature was 300 K and pressure ratio was 5 : 1 as the boundary conditions. The density function was derived from the ideal gas law and the viscosity function was derived from Sutherland viscosity law. The pressure ratio along the ejection distance decreased more in the lower density working fluids. In the case of the higher density working fluids, however, the Mach number was lower. This shows that the density of the working fluids has a considerable effect on the shock wave. Therefore, the reliability of the analysis results were improved by experiments and CFD analysis showed that supersonic jet flow affects the shock wave by changing shape and diameter of the jet, pressure ratio, etc. according to working fluids.

A Study on the Removal of Dissolved Matter in Groundwater and Characteristics of Fouling using NF and RO (NF와 RO를 이용한 지하수중 용존성 물질의 제거와 막 오염의 특성에 관한 연구)

  • Gwon, Eun-Mi;Yu, Myong-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2205-2213
    • /
    • 2000
  • To investigate removal efficiency of dissolved matter by NF and RO, a pilot plant was operated for six months using groundwater treated by UF membrane. After the pilot plant operation, we performed autopsy test to identify characteristics of foulant attached on the membrane surface applying the used NF and RO in the pilot plant test. In autopsy test, we measured permeate flux and recovery rate of flux by chemical cleaning in each membrane. We also analyzed chemical cleaning disposal to examine component of foulant. Permeate flux of NF and RO1 showed rapid decline after 100 days of operation. Especially, reduction of specific flux in RO1 was more serious than in NF. Specific flux of RO2 with a low recovery rate resulted in gradual flux decline. Removal efficiencies of dissolved inorganic matters as a conductivity were 76.3%, 88.2% and 95.3% respectively for NF, RO1 and RO2, and RO2 presented the highest removal efficiency. And those of dissolved organic matters as TOC were about 80% for both NF and RO. The specific flux of membranes declined gradually from the feed water inlet to outlet of the membrane module and it showed that membrane fouling increased along the feed flow direction. Namely, concentration of pollutants became higher and volume of feed water was less as the feed flow approached to the outlet. It seemed that major foul ants were Ca consolidated into inorganic material and Si consolidated into organic material on the membrane surface. Fe was a great contribution to irreversible fouling. The SEM results indicated that the organic matter was attached to the first layer, closer to the membrane, and then inorganic matter with tetragonal shape layered over them. We could not observe biofouling because microorganism, which was cause of biofouling, was almost pretreated in UF membrane.

  • PDF

Optimization Techniques for the Inverse Analysis of Service Boundary Conditions in a Porous Catalyst Substrate with Fluid-Structure Interaction Problems (유체 구조 상호작용 문제를 가진 다공성 촉매 담체에서 실동경계조건의 역문제 해석을 위한 최적화 기법)

  • Baek, Seok-Heum;Cho, Seok-Swoo;Kim, Hyun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1161-1170
    • /
    • 2011
  • This paper presents a solution to the inverse problem for the service boundary conditions of thermal-flow and structure analysis in a catalyst substrate. The exhaust-gas purification efficiency of a catalyst substrate is influenced by the shape parameter, catalyst ingredients and so on and is estimated by the thermal flow uniformity. The formulations of the inverse problem of obtaining the thermal-flow parameters (inlet temperature, velocity, heat of reaction, convective heat-transfer coefficient) and the direct problem of estimating from a given outlet temperature distribution are described. An experiment was designed and the response-surface optimization technique was used to solve the proposed inverse problem. The temperature distribution of the catalyst substrate was obtained by thermal-flow analysis for the predicted thermal-flow parameters. The thermal stress and durability assessments for the catalyst substrate were performed on the basis of this temperature distribution. The efficiency and accuracy of the inverse approach have been demonstrated through the achievement of good agreement between the thermal-flow response surface model and the results of experimental vehicle tests.

Effect of Inlet Shape on Thermal Flow Characteristics for Waste Gas in a Thermal Decomposition Reactor of Scrubber System (반도체 폐가스 처리용 열분해반응기의 입구형상이 열유동 특성에 미치는 영향에 관한 수치해석 연구)

  • Yoon, Jonghyuk;Kim, Youngbae;Song, Hyungwoon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.510-518
    • /
    • 2018
  • Recently, lots of interests have been concentrated on the scrubber system that abates waste gases produced from semiconductor manufacturing processes. An effective design of the thermal decomposition reactor inside a scrubber system is significantly important since it is directly related to the removal performance of pollutants and overall stabilities. In the present study, a computational fluid dynamics (CFD) analysis was conducted to figure out the thermal and flow characteristics inside the reactor of wet scrubber. In order to verify the numerical method, the temperature at several monitoring points was compared to that of experimental results. Average error rates of 1.27~2.27% between both the results were achieved, and numerical results of the temperature distribution were in good agreement with the experimental data. By using the validated numerical method, the effect of the reactor geometry on the heat transfer rate was also taken into consideration. From the result, it was observed that the flow and temperature uniformity were significantly improved. Overall, our current study could provide useful information to identify the fluid behavior and thermal performance for various scrubber systems.

A Study on the Injection Molding Analysis of the Metal Powder Material (금속분말재료의 사출 성형해석에 관한 연구)

  • Ro, Chan-Seung;Park, Jong-Nam;Jung, Han-Byul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.42-47
    • /
    • 2017
  • In this study,we conducted an injection molding analysis of metal powder materials for the development of flanges, which are necessary adapters for optical communication. The metal powder injection molding process is a technique for producing an injection molded article having a complicated shape by mixing ceramic or stainless powder and binders. It is used to produce products which require complex processing technology or for which the productivity is low. The purpose of this study is to minimize the manufacturing processing of products which are manufactured through existing mechanical processing procedures. For the injection molding analysis, we mixed stainless STS316 metal powder with binders at a ratio of 6 to 4 to make molding materials consisting of granular pellets. Then, three-dimensional modeling and meshing were carried out to obtain the optimal injection molding analysis conditions(molding temperature, melting temperature, injection time, injection temperature, injection pressure, packing time and cooling time). As a result of the analysis, it was discovered that the inlet became available 13.29 seconds after the first injection. Also, as the flowing and packing in the melt through the sprue, runner and gate were stable, it is expected that good molds can be manufactured.