Study on frost Generation and Defrosting Mechanism on Evaporating Tubes for Refrigerator and Air condition industries (냉동공조용 관군에서의 서리발생 및 제상 메커니즘에 관한 연구)

  • Jee, Jae-Hoon;Kim, Chang-Bok;Mun, Sung-Bae;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.234-235
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is 15$^{circ}C$, 20$^{circ}C$, 25$^{circ}C$ , supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept -15$^{circ}C$ because, generally cooling temperature range is constantly -15$^{circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost thickness in each condition and examine these data

  • PDF

Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction (백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구)

  • Wang, Zhen-Huan;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.

A study on frost generation and difrosting mechanism on evaporating tubes for Air-conditioning system (냉동공조용 증발기에서 서리의 발생 및 제상 메커니즘에 관한 연구)

  • Jee, Jae-Hoon;Kim, Chang-Bok;Kim, Myung-Hwan;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.166-171
    • /
    • 2005
  • In this experiment study, to acquire elementary data for explaining to generate frost layer in the fin - tube evaporator. the experiment condition is to supply air on 0.3m/s, 0.6m/s, 0.9m/s and inlet air temperature is kept constantly $20^{\circ}C$, supplied air relative humidity is 70%, 80, 90%. And brine temperature in the copper tube was kept $-15^{\circ}C$ because, generally cooling temperature range is constantly $-15^{\circ}C$ in the heat exchanger for air conditioning system. in conclusion, through this experiment, we did compare with frost layer and frost quantity in each condition and examine these data

  • PDF

Comparison of Condenser Characteristics using R410A and R22 under the Same Inlet Temperature Condition (동일한 유입온도조건에서 R410A와 R22 적용 응축기의 특성비교)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1049-1059
    • /
    • 2003
  • R410A is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the heat transfer and pressure drop for R410A flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.6 m/s. Experiments show that air velocity decreased by 16% is needed for R410A than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop decrease of 15% for R410A as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires lower electric-power consumption with R410A than that with R22.

Comparison of Condenser Characteristics Using R407C and R22 on the Same Inlet Temperature Condition (동일한 유입온도조건에서 R407C와 R22 적용 응축기의 특성비교)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.595-603
    • /
    • 2003
  • R407C is considered as an alternative refrigerant to R22 for air conditioners. An experimental investigation was made to study the characteristics of the condensation heat transfer and pressure drop for R407C flowing in a fin-and-tube heat exchanger used for commercial air-conditioning units. Experiments were carried out under the conditions of inlet refrigerant temperature of 6$0^{\circ}C$ and refrigerant mass flux varying from 150 to 250 kg/$m^2$s for refrigerant side. The inlet air has dry bulb temperature of 35$^{\circ}C$ , relative humidity of 50% and air velocity varying from 0.8 to 1.6 m/s. Experiments show that air velocity increased by 25% is needed for R407C than that of R22 for subcooling temperature of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 28.8% for R407C as compared to R22. As a consequence, in order to provide the same design condition of a condenser, the fan requires higher electric-power consumption with R407C than that with R22.

An Experimental Study on the Effect of Air Temperature and Humidity on Humidification Performance of the Humidifying Element Used for Air Conditioning (공기 온습도가 공조용 가습 소자의 가습 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.732-740
    • /
    • 2019
  • Evaporative humidification using a humidifying element is widely used for humidification of a building or a data center. The performance of a humidifying element is commonly expressed as humidification efficiency, which is used independent of air temperature, humidity and water temperature. In this study, a series of tests were conducted at two air conditions (data center and commercial building) using two different humidifying elements (cellulose/PET and Glasdek) changing the frontal air velocity and water temperature. Results showed that the measured humidification efficiency was dependent on the air condition and water temperature. In fact, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. The reason was due to the inlet water temperature, which was lower than the dew point air temperature. As the difference between the inlet water and the dew point air temperature increased, the humidification efficiency decreased. This suggest that proper thermal model should account for the inlet region, where the amount of moisture transfer may be different from the other part of the humidification element. A simple analysis on the thermal performance of the cellulose/PET humidification element showed that the Sherwood number was adequately predicted, whereas the friction factor was ovepredicted, probably due to the simplification of the channel geometry and the neglection of the water film on the element surface.

Heat Transfer and Friction Characteristics of Louver Fin and Tube Heat Exchangers under Wet Conditions (루버핀-관 열교환기의 습조건에서의 열전달 및 마찰특성에 대한 실험 연구)

  • Kwon, Young Chul;Chang, Keun Sun
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.73-79
    • /
    • 2008
  • An experimental study was conducted to investigate the effect of a tube row, a fin pitch and an inlet humidity on air-side heat and mass transfer performance of louvered fin-tube heat exchangers under wet conditions. Experimental conditions were varied by three fin pitches, two rows, two inlet relative humidities. Experimental results showed that the heat transfer performance decreased and the friction increased with the decrease of fin pitch, for 2 row heat exchanger. The effect of fin pitch on heat transfer performance was negligible with 3 row heat exchanger. The changes in relative humidity was not affected heat transfer and friction. However, the mass transfer performance was slightly decreased with the increase of relative humidity and with the decrease of fin pitch. The mass transfer performance of the louvered fin-tube heat exchanger decreased with the decrease of the fin pitch and was different according to the number of tube row.

Optimization of PEM Fuel Cell System Using a RSM (반응표면기법에 의한 고분자전해질형 연료전지 시스템의 최적화)

  • Xuan, Dongji;Kim, Jin-Wan;Nan, Yanghai;Ning, Qian;Kim, Young-Bae
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3140-3141
    • /
    • 2008
  • The output power efficiency of the fuel cell system depends on the demanded current, stack temperature, air excess ratio, hydrogen excess ratio and inlet air humidity. Thus, it is necessary to determine the optimal operation condition for maximum power efficiency. In this paper, we developed a dynamic model of fuel cell system which contains mass flow model, diffusivity gas layer model, membrane hydration and electrochemistry model. In order to determine the maximum output power and minimum use of hydrogen in a certain power condition, response surface methodology (RSM) optimization based on the proposed PEMFC stack model is presented. The results provide an effective method to optimize the operation condition under varied situations.

  • PDF

Degradation of Membrane With Pinholes in PEMFC (고분자 전해질 연료전지에서 Pinhole 있는 막의 열화)

  • Kim, Tae-Hee;Lee, Ho;Lim, Tae-Won;Park, Kwon-Pil
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.2
    • /
    • pp.103-110
    • /
    • 2008
  • The most failure mode of PEM fuel cell is gas crossover caused by pinhole formation in MEAs. The degradation phenomena of MEA with pinholes were evaluated in various accelerated operation condition, such as OCV, low humidity and high partial pressure of oxygen. The performances of MEA with pinholes were almost same before and after normal 144 hours operation($70^{\circ}C$, $640mA/cm^2$, 65%RH $H_2/air$). The results of accelerated operation showed that OCV and low humidity condition more deteriorated MEA than gas crossover owing to pinholes. When oxygen was used as cathode gas, the pinholes of MEA were enlarged due to heat of combustion reaction on Pt catalyst of electrodes. This combustion reaction occurred at pinholes near gas inlet and resulted in local MEA failure.

The study on the estimation of heat transfer coefficient through the counterflow concentric tube using refrigerant and moisture air (냉매와 습공기가 교차하는 2중관에서 전열계수 예측을 위한 연구)

  • 조권희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.687-694
    • /
    • 1999
  • This study was conducted to develop new drying process for automatic control and marine engi-neering system. Air-water tests were carried out to investigate dryer performance. The dispersed flow in he dryer test apparatuses was also simulated by using a numerical code which solves the Dittus-Boelter equation for continuous liquid phase and the Reynolds equation of droplet motion for continuous liquid phase and the Reynolds equation of droplet motion for dispersed phase to predict droplet removal efficiency. Proper conditions for dehumidification were optimized by response ambient conditions. When the selected indexes were constrained in the range of 85-98% moisture content above $15^{\circ}$ and more than mass flow rates of moist air 750kg/h. The numerical results were compared with the experimental data pertaining to the removal effi-ciency at chamber stage and overall pressure drop along concentric tubes Good agreement was obtained as for the efficiency while relatively poor agreement was obtained for the relative humidity. The results also showed that the efficiency depended strongly on the relative humidity at the inlet condition which indicated the importance of estimating the heat exchanger length. Effects of some design parameters in both removal efficiency and breakthrough onset condition are discussed.