• Title/Summary/Keyword: Injection test

Search Result 2,183, Processing Time 0.04 seconds

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

Evaluation of the Potential of Nitrogen Plasma to Cosmetics (질소 플라즈마의 화장품 가능성 평가)

  • Lee, So Min;Jung, So Young;Brito, Sofia;Heo, Hyojin;Cha, Byungsun;Lei, Lei;Lee, Sang Hun;Lee, Mi-Gi;Bin, Bum-Ho;Kwak, Byeong-Mun
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.3
    • /
    • pp.189-196
    • /
    • 2022
  • Plasma refers to an ionized gas that is often referred to as "the fourth phase of matter", following solid, liquid, and gas. Plasma has traditionally been utilized for industrial applications such as welding and neon signs, but its promise in biomedical fields such as cancer treatment and dermatology has lately been recognized. Indeed, due to its beneficial effects in promoting collagen production, improving skin tone, and eliminating harmful bacteria in the skin, plasma treatment constitutes an important target for dermatological research. In this study, a plasma device for cosmetic manufacturing based on nitrogen, the main component of the atmosphere, was designed and assembled. Moreover, nitric oxide (NO) was selected since is easier to follow and evaluate than other nitrogen plasma active species, and its contents were measured to perform a quantitative and qualitative evaluation of plasma. First, an injection method, using different proximities labeled "sinking" and "non sinking" treatments, was performed to test the most efficient plasma treatment method. As a result, it was observed that the formulation obtained by a non sinking treatment was more effective. Furthermore, toner and ampoule were selected as cosmetics formulations, and the characteristics of the formulation and changes in the injected plasma state were observed. In both formulations, the successful injection of NO plasma was 2 times higher in toner formulation than ampoule formulation, and it gradually decreased with time, having dissipated after a week. It was confirmed that the nitrogen plasma used did not affect the stability of the toner and ampoule formulations at low temperature (4 ℃), room temperature (25 ℃), and high temperature (37 ℃ and 50 ℃) conditions. The results of this study demonstrate the potential of plasma cosmetics and highlight the importance of securing the stability of the injected plasma.

Studies on effect and Safety of various Aqua-acupunctures from Scutellariae Radix (다양(多樣)한 황금약침제제(黃芩藥鍼製劑)의 안전성(安定性) 및 효능(效能)에 관한 연구(硏究))

  • Kim, Ho-Kyoung;Ma, Jin-Yeul;Cheon, Won-Kyung;Yun, Su-Young;Kang, Eun-Jung;Joo, Hye-Jeong;Ko, Byoung-Seob
    • Korean Journal of Oriental Medicine
    • /
    • v.3 no.1
    • /
    • pp.183-197
    • /
    • 1997
  • In order to detect the safety and effect of various aqua-acupunctures from Scutellariae Radix, the modifications of boiling, filtration and dilution were employed for the manufacture of aqua-acupunctures. We injected 0.2cc of aqua-acupunctures into Joksamri (足三里) of rat, repeatedly. We compared subacute toxicity of them with saline group, distilled water(D.W.) group, acupuncture group and control group. The results were summarized as follows: 1. The groups were all healthy and alive, and there was no special abnormality in physical condition and autopsy. And there were not any toxic symptoms in repeating application of aqua-acupunctures to the rat, including changes of body weight, organ weight, haematological examination and serum biochemical test. 2. There was slight change of body weight in acupuncture group : We could see significance after 3 days(p<0.05) and after 7 days(p<0.001) in body weight loss. After 9 days, all tested groups were suppressed in body weight increment. 3. Result of organ weight : In Palkang aqua-acupuncture(D-2 group), saline group and acupuncture group there were some statistical significance. Especially, acupuncture group revealed significant result in liver and spleen than aqua-acupunctures. From this result, we could suggest that the efficacy of acupuncture was preceded herbal medicine. 4. In serum biochemical test, we examined glucose(GLU), triglyceride(TG) and cholesterol(CHOL). In comparison with control group, the diluted 10 times of Hwanggum aqua-aqupuncture$({\times}10\;group)$ was recognized significant decrease of glucose, but the diluted 100 times of Hwanggum aqua-acupuncture$({\times}100\;group)$, D-2 group, saline group were confirmed significant increment. There was not any meaningful change of CHOL in all of tested group, excepting the acupuncture group was exhibited statistically significant decrease(p<0.05). In TG level all tested group except complex injection of standard compound(CPA group) and HG, there were significant value iii statistically. The diluted solution was more significant decrease than Hwanggum aqua-acupuncture(HG). The mutual relationship of components of aqua-acupunture tended to decrease level of TG, regardless of its concentration. In acupunture guoup, we gained some interesting result In meaningful decrease in 7G. 5. Haematological examination showed significant increment of granulocytes(GR) in all tested groups except Hwanggum aqua-acupuncture. And the diluted solutions of HG expressed very high increment of them(p<0.001). The GR and Mean Corpuscular Volume(MCV) of acupuncture group showed statistical significance.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Performance Analysis of a Deep Vertical Closed-Loop Heat Exchanger through Thermal Response Test and Thermal Resistance Analysis (열응답 실험 및 열저항 해석을 통한 장심도 수직밀폐형 지중열교환기의 성능 분석)

  • Shim, Byoung Ohan;Park, Chan-Hee;Cho, Heuy-Nam;Lee, Byeong-Dae;Nam, Yujin
    • Economic and Environmental Geology
    • /
    • v.49 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Due to the limited areal space for installation, borehole heat exchangers (BHEs) at depths deeper than 300 m are considered for geothermal heating and cooling in the urban area. The deep vertical closed-loop BHEs are unconventional due to the depth and the range of the typical installation depth is between 100 and 200 m in Korea. The BHE in the study consists of 50A (outer diameter 50 mm, SDR 11) PE U-tube pipe in a 150 mm diameter borehole with the depth of 300 m. In order to compensate the buoyancy caused by the low density of PE pipe ($0.94{\sim}0.96g/cm^3$) in the borehole filled with ground water, 10 weight band sets (4.6 kg/set) were attached to the bottom of U-tube. A thermal response test (TRT) and fundamental basic surveys on the thermophysical characteristics of the ground were conducted. Ground temperature measures around $15^{\circ}C$ from the surface to 100 m, and the geothermal gradient represents $1.9^{\circ}C/100m$ below 100 m. The TRT was conducted for 48 hours with 17.5 kW heat injection, 28.65 l/min at a circulation fluid flow rate indicates an average temperature difference $8.9^{\circ}C$ between inlet and outlet circulation fluid. The estimated thermophysical parameters are 3.0 W/mk of ground thermal conductivity and 0.104 mk/W of borehole thermal resistance. In the stepwise evaluation of TRT, the ground thermal conductivity was calculated at the standard deviation of 0.16 after the initial 13 hours. The sensitivity analysis on the borehole thermal resistance was also conducted with respect to the PE pipe diameter and the thermal conductivity of backfill material. The borehole thermal resistivity slightly decreased with the increase of the two parameters.

Research of Corrosion Control Technology for the Product Water of SWRO(Seawater Reverse Osmosis) by using liquid lime (액상소석회를 이용한 SWRO 생산수의 부식제어 연구)

  • Kim, Min-Chul;Hwang, Kyu-Won;Woo, Dal-Sik;Yoon, Seok-Min;Kwak, Myung-Hwa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.529-536
    • /
    • 2011
  • In this study, we confirmed that the SWRO(Sea Water Reverse Osmosis) production water has more hard corrosiveness than the tap water by fundamental experiment. According to the result, the target of this study was aimed at developing maintenance and anti-corrosion method. In the early stages of the research, batch tests using mild steel coupons and electrochemical experiments were applied to compare the corrosiveness between SWRO production water and the tap water. After then, two corrosion control methods for SWRO production water were applied. Liquid lime($Ca(OH)_2$) and Carbon Dioxide($CO_2$) were inserted and compared with the combination of liquid lime with phosphate corrosion inhibitor and carbon dioxide. The water qualities were evaluated through LSI(Langelier Saturation Index) and proper injection ratio was deduced by the result. Since then, simulated loop system test were performed to evaluate anti-corrosion effect depending on corrosion inhibitors. Subsequently, carbon steel pipes equipped at the loop system were detached for SEM, EDX and XRD analysis to acquire quantitative and qualitative data of the major corrosion products inside the pipes. In conclusion, the controled groups with anti-corrosion techniques applied were effective by appearing 97.4% and 90.9% of improvements in both case of liquid lime and the liquid lime with a phosphate corrosion Inhibitor. furthermore, major components of scale were iron oxides, on the other hand, protective effect of film formation by calcium carbonate($CaCO_3$) could be confirmed.

Comparative Study of Perinatal Outcome and the Incidene of Congenital Anomalies of Babies Born after Intracytoplasmic Sperm Injection (ICSI) and Conventional In-vitro Fertilization (IVF) (고식적 체외수정시술과 난자 세포질내 정자주입술에 의해 태어난 아이의 주산기 결과 및 선천성 기형 발생빈도의 비교 연구)

  • Lim, Jeong-Eun;Yoo, Keun-Jai;Lee, Jong-Pyo;Lee, Moon-Seob;Hyun, Woo-Young;Jun, Jin-Hyun;Hong, Soo-Jeong;Song, Ji-Hong;Song, In-Ok;Paik, Eun-Chan;Choi, Bum-Chae;Son, Il-Pyo;Koong, Mi-Kyoung;Kang, In-Soo;Jun, Jong-Young;Park, In-Sou
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.25 no.3
    • /
    • pp.323-329
    • /
    • 1998
  • The safety of ICSI as a novel procedure of assisted fertilization may be assessed by the health of the baby born. In order to evaluate the safety of ICSI, perinatal outcome and congenital anomaly of the babies born after ICSI were compared with those of babies born after IVF (control group). We analysed the clinical data from the obstetric and pediatric records, including the information obtained through telephone. The results are as follows; Mean gestational age $({\pm}SEM)$ and birth weight in singleton pregnancy were $38.8{\pm}1.9$ weeks and $3209.7{\pm}501.9gm$ in IVF group, $39.0{\pm}2.2$ weeks and $3289.9{\pm}479.5gm$ in ICSI group, respectively. Mean gestational age and birth weight in twins were $36.8{\pm}2.1$ weeks and $2512.8{\pm}468.0gm$ in IVF group, $36.5{\pm}2.8$ weeks and $2492.7{\pm}537.1gm$ in ICSI group. In IVF group, perinatal mortality rates were 8.5 in singletons and 56.6 in twins; for the ICSI singletons and ICSI twins, the perinatal mortality rates were 11.6 and 49.0, respectively. The incidence of congenital malformations was 3.6% (8/224) in IVF group and 2.1% (4/188) in ICSI group, there was no statistical difference (p>0.05, Fisher's exact test). The incidence of major congenital anomalies was 0.9% (2/224; pulmonary artery hypoplasia, renal cystic dysplasia) in IVF group and 1.1% (2/188; holoprosencephaly, Cri du chat syndrome) in ICSI groups (p>0.05, Fisher's exact test). Similarly, there was no significant difference in incidence of minor congenital anormalies 2.7% (6/224) in IVF group and 1.1% (2/188) in ICSI group respectively (p>0.05, Fisher's exact test). In conclusion, there was no difference in the perinatal outcome and the incidence of congenital anomalies between the babies born after ICSI and those after conventional IVF.

  • PDF

Effectiveness of Soft Stimulation Protocol, Compared with Conventional GnRH Antagonist Multiple dose Protocol in Patients Undergoing Controlled Ovarian Stimulation with Intrauterine Insemination (과배란유도하 자궁강내 인공수정시술을 받는 환자에서 연성자극요법과 성선자극호르몬 길항제 다회투여법의 효과 비교)

  • Kim, Chung-Hoon;Kang, Hyuk-Jae;Kim, So-Ra;Jeon, Gyun-Ho;Lee, Hyang-Ah;Kim, Sung-Hoon;Chae, Hee-Dong;Kang, Byung-Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.2
    • /
    • pp.135-142
    • /
    • 2010
  • Objective: To evaluate the effectiveness of soft stimulation protocol using GnRH antagonist/clomiphene citrate (CC)/recombinant FSH (rFSH) in patients undergoing controlled ovarian stimulation (COS) with intrauterine insemination (IUI), compared with GnRH antagonist multiple dose protocol (MDP) using GnRH antagonist/rFSH. Methods: Eighty infertile women were randomized to soft stimulation protocol group (n=40) or GnRH antagonist MDP group (n=40). In both groups, IUI was performed 36~40 hours after hCG injection. Statistical analysis was performed using Student's t-test, $\chi^2$ test or Fisher's exact test as appropriate. Results: Total dose and days of rFSH required for COS were significantly fewer in soft stimulation protocol group (p<0.001, p<0.001). A premature LH surge did not occur in any patients of both groups. Clinical pregnancy rate per cycle was similar between the two groups. Conclusion: Soft stimulation protocol provides comparable pregnancy rates to GnRH antagonist MDP despite fewer total dose and days of rFSH, and so can become one of the patient-friendly, cost-effective alternatives for infertile patients undergoing COS with IUI.

Utilization of Song-Gang Stone as the Dietary Additve in Juvenile Olive Flounder, Paralichthys olivacus (치어기 넙치에 있어서 사료 첨가제로서 송강약돌의 이용 가능성)

  • 최세민;고수홍;박건준;임성률;유광열;이제희;배승철
    • Journal of Aquaculture
    • /
    • v.17 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • Three experiments were conducted to determine utilization of Song-Gang(equation omitted) stone as the dietary additive for growth and immune stimulant in juvenile olive flounder. In the feeding trial, four diets were formulated to contain 0, 0.5, 1.0 and 2.0% Song-Gang(equation omitted) stone per kg diet (SGS$_{0}$ , SGS$_{0.5}$, SGS$_{1.0}$ , SGS$_{2.0}$ ). Fish averaging 5.0$\pm$0.04 g (mean$\pm$SD) were fed one of four experimental diets in triplicate groups for 8 weeks. There were no significant differences in weight gain, feed efficiency, protein efficiency ratio, hematosomatic index, condition factor and survival among fish fed all the diets. In chanlenge test, fish were infected by intraperitoneal injection of 0.1 $m\ell$ bacterial suspension with Edwardsielia tarda per fish after the feeding trial. Fish fed SGS$_{0.5}$ diet have a significantly higher cumulative survival rate than did fish fed the other diets (P<0.05). In the anti-mold test, Asprrgiilus niger, Penicillium pinophiltfm, Chaeromium globosum were inoculated with Song-Gang(equation omitted) stone using ASTM G-21 method. The amount of Α. niger, Ρ. pinuphiium. C. globosum didn't increase in Song-Gang(equation omitted) stone for 4 weeks for the test period. Therefore, these results indicate that 0.5% Song-Gang(equation omitted) stone per kg diet could increase immune resistance in juvenile olive flounder and Song-Gang(equation omitted) stone could be used as the anti-mold additive in fish feed.

The Influence of Iteration and Subset on True X Method in F-18-FPCIT Brain Imaging (F-18-FPCIP 뇌 영상에서 True-X 재구성 기법을 기반으로 했을 때의 Iteration과 Subset의 영향)

  • Choi, Jae-Min;Kim, Kyung-Sik;NamGung, Chang-Kyeong;Nam, Ki-Pyo;Im, Ki-Cheon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.122-126
    • /
    • 2010
  • Purpose: F-18-FPCIT that shows strong familiarity with DAT located at a neural terminal site offers diagnostic information about DAT density state in the region of the striatum especially Parkinson's disease. In this study, we altered the iteration and subset and measured SUV${\pm}$SD and Contrasts from phantom images which set up to specific iteration and subset. So, we are going to suggest the appropriate range of the iteration and subset. Materials and Methods: This study has been performed with 10 normal volunteers who don't have any history of Parkinson's disease or cerebral disease and Flangeless Esser PET Phantom from Data Spectrum Corporation. $5.3{\pm}0.2$ mCi of F-18-FPCIT was injected to the normal group and PET Phantom was assembled by ACR PET Phantom Instructions and it's actual ratio between hot spheres and background was 2.35 to 1. Brain and Phantom images were acquired after 3 hours from the time of the injection and images were acquired for ten minutes. Basically, SIEMENS Bio graph 40 True-point was used and True-X method was applied for image reconstruction method. The iteration and Subset were set to 2 iterations, 8 subsets, 3 iterations, 16 subsets, 6 iterations, 16 subsets, 8 iterations, 16 subsets and 8 iterations, 21 subsets respectively. To measure SUVs on the brain images, ROIs were drawn on the right Putamen. Also, Coefficient of variance (CV) was calculated to indicate the uniformity at each iteration and subset combinations. On the phantom study, we measured the actual ratio between hot spheres and back ground at each combinations. Same size's ROIs were drawn on the same slide and location. Results: Mean SUVs were 10.60, 12.83, 13.87, 13.98 and 13.5 at each combination. The range of fluctuation by sets were 22.36%, 10.34%, 1.1%, and 4.8% respectively. The range of fluctuation of mean SUV was lowest between 6 iterations 16 subsets and 8 iterations 16 subsets. CV showed 9.07%, 11.46%, 13.56%, 14.91% and 19.47% respectively. This means that the numerical value of the iteration and subset gets higher the image's uniformity gets worse. The range of fluctuation of CV by sets were 2.39, 2.1, 1.35, and 4.56. The range of fluctuation of uniformity was lowest between 6 iterations, 16 subsets and 8 iterations, 16 subsets. In the contrast test, it showed 1.92:1, 2.12:1, 2.10:1, 2.13:1 and 2.11:1 at each iteration and subset combinations. A Setting of 8 iterations and 16 subsets reappeared most close ratio between hot spheres and background. Conclusion: Findings on this study, SUVs and uniformity might be calculated differently caused by variable reconstruction parameters like filter or FWHM. Mean SUV and uniformity showed the lowest range of fluctuation at 6 iterations 16 subsets and 8 iterations 16 subsets. Also, 8 iterations 16 subsets showed the nearest hot sphere to background ratio compared with others. But it can not be concluded that only 6 iterations 16 subsets and 8 iterations 16 subsets can make right images for the clinical diagnosis. There might be more factors that can make better images. For more exact clinical diagnosis through the quantitative analysis of DAT density in the region of striatum we need to secure healthy people's quantitative values.

  • PDF