• Title/Summary/Keyword: Injection technique

Search Result 938, Processing Time 0.027 seconds

Seismic repair of reinforced concrete beam-column subassemblages of modern structures by epoxy injection technique

  • Tsonos, Alexander G.
    • Structural Engineering and Mechanics
    • /
    • v.14 no.5
    • /
    • pp.543-563
    • /
    • 2002
  • The use of the epoxy pressure injection technique to rehabilitate reinforced concrete beam-column joints damaged by strong earthquakes is investigated experimentally and analytically. Two one-half-scale exterior beam-column joint specimens were exposed to reverse cyclic loading similar to that generated from strong earthquake ground motion, resulting in damage. Both specimens were typical of new structures and incorporated full seismic details in current building codes. Thus the first specimen was designed according to Eurocode 2 and Eurocode 8 and the second specimen was designed according to ACI-318 (1995) and ACI-ASCE Committee 352 (1985). The specimens were then repaired with an epoxy pressure injection technique. The repaired specimens were subjected to the same displacement history as that imposed on the original specimens. The results indicate that the epoxy pressure injection technique was effective in restoring the strength, stiffness and energy dissipation capacity of specimens representing a modem design.

Rock Permeability Estimation from Hydraulic Injection Tests in a Sealed Borehole Interval

  • Quach, Nghiep Q.;Jo, Yeonguk;Chang, Chandong
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • We propose a borehole test technique to estimate permeability of rocks in borehole. The borehole tests are hydraulic injection tests such as leak-off test and hydraulic fracturing tests, which are originally conducted for stress or casing integrity assessment and not for permeability measurement. We use one-dimensional radial diffusion equation to interpret fluid injection test results in terms of permeability. We apply this technique to a leak-off test conducted at a depth of 700 m in a wellbore, where rock formation is mudstone. The estimated permeability is at an order of $10^{-16}m^2$, which is somewhat high but within the range reported for mudstones previously. Quantitative rick assessment suggests that an accurate measurement of open hole section length is important to improve reliability of results. More data may be needed to ensure the reliability of this technique. If validated, however, this technique can provide cost-effective estimation of in situ permeability without conducting independent permeability tests in borehole.

Comparison of Multilevel with Single Level Injection during Lumbar Sympathetic Ganglion Block: Efficacy of Sympatholysis and Incidence of Psoas Muscle Injection

  • Hong, Ji-Hee;Oh, Min-Ju
    • The Korean Journal of Pain
    • /
    • v.23 no.2
    • /
    • pp.131-136
    • /
    • 2010
  • Background: We prospectively evaluated the incidence and possible factors causing intramuscular injection during lumbar sympathetic ganglion block and compared the multiple needle technique to the single technique to obtain a profound and complete block effect. Methods: Among 83 patients, 58 patients (group A, n = 27, multiple needle technique and group B, n = 31, single needle technique) were reevaluated for the changes of skin temperature (Ts) and mean segment of longitudinal contrast spread. After injecting the contrast agent, the incidence of psoas muscle injection and the change of Ts was compared between two groups. Results: The incidence of psoas muscle injection was 21.3% (46/216) and it was associated with the level of injection (L2) significantly (${\chi}_2$ = 14.773, P = 0.001). $DT^{post}$ (postblock temperature difference between ipsilateral and contralateral great toe, $4.6{\pm}2.8^{\circ}C$, $1.8{\pm}1.6^{\circ}C$, P < 0.001 for group A and B) and $DT^{net}$ ($DT^{post}$ - $DT^{pre}$, $3.9{\pm}2.7^{\circ}C$, $1.5{\pm}1.5^{\circ}C$, P < 0.001 for group A and B) was significantly higher in group A. The mean segment of longitudinal contrast spread was $8.1{\pm}0.9$ for group A and $3.2{\pm}1.6$ for group B (P < 0.001). Conclusions: The LSGB at the L2 level showed the lowest incidence of psoas muscle injection of contrast. Multiple needle approach showed more significant increase of $DT^{net}$ and $DT^{post}$.

Development of Injection Moulding Method of Sabot using Polyetherimide Composite Material (PEI계 복합 재료를 이용한 탄자 운반체의 사출 성형 기술 개발에 관한 연구)

  • 정태형;이범재;하영욱;이성계
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.269-274
    • /
    • 2001
  • This research covers the development of new technique for composite injection molding of high stiffness Sabot. An analysis of polymer resin is performed by means of making test specimen mold and doing test with accordance of ASTM test guidelines. Structural analysis and simulation of injection molding process are carried out in order not only to estimate but also to predict the characteristics of molding stresses what both product and structure of mold may have. For structural analysis software, Moldflow and LS-dyna are used and universal test machine is utilized for evaluating performance of sabot. Cases of adopting this material to sabot are not announced yet in domestic academic world. In addition to that, materials for polymer-metal mixed injection molding are imported on the whole due to deficient level of domestic technology. Therefore, this new developed injection molding technique using PEI material can make it available to ensure the technology of making mold, injection and design. Finally, this technique may be applicable to another sabot having different radius of warheads from now on.

  • PDF

Investigation of pressure-volume-temperature relationship by ultrasonic technique and its application for the quality prediction of injection molded parts

  • Kim Jung Gon;Kim Hyungsu;Kim Han Soo;Lee Jae Wook
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.4
    • /
    • pp.163-168
    • /
    • 2004
  • In this study, an ultrasonic technique was employed to obtain pressure-volume-temperature (PVT) rela­tionship of polymer melt by measuring ultrasonic velocities under various temperatures and pressures. The proposed technique was applied to on-line monitoring of injection molding process as an attempt to predict quality of molded parts. From the comparison based on Tait equation, it was confirmed that the PVT behav­ior of a polymer is well described by the variation of ultrasonic velocities measured within the polymer medium. In addition, the changes in part weight and moduli were successfully predicted by combining the data collected from ultrasonic technique and artificial neural network algorithm. The results found from this study suggest that the proposed technique can be effectively utilized to monitor the evolution of solid­ification within the mold by measuring ultrasonic responses of various polymers during injection molding process. Such data are expected to provide a critical basis for the accurate prediction of final performance of molded parts.

The Application of Gas Injection Technology for the Automobile Handle Part (자동차용 핸들 성형시 Gas Injection 응용)

  • Heo Y. M.;Shin K. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.103-108
    • /
    • 2002
  • The gas injection molding technique(GIT) is a special injection molding process and has been an established and acknowledged process technique for many years. GIT has proved successful in cases where warpage has to be minimized, sink marks avoided and material input reduced. The classic field of application for GIT, however, is the production of thick-walled, rod shaped parts or hollow articles. Through this application, the handle part for automobile is molded and this part is consequently used as a insert for the additional injection molding process encapsulated with PVC.

  • PDF

The Whole Region Pressure Measurement of Cavity Downstream using PSP Technique (PSP를 이용한 Cavity 후류의 전역적 압력분포 측정)

  • Kim, Ki-Su;Jeon, Young-Jin;Seo, Hyung-Seok;Byun, Yung-Hwan;Lee, Jae-Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.317-321
    • /
    • 2007
  • PSP (Pressure Sensitive Paint) technique can measure continuous pressure field by analyzing the oxygen quantity using optical method. The surface pressure of down stream after the sonic jet that injected transversely into the supersonic freestream was measured by PSP technique. Moreover the effect of various rectangular shaped cavities in front of the jet was measured by PSP technique. A comparison of the PSP results with conventional pressure tap and CFD indicates good agreement. The result shows that the cavity affects the pressure distribution in the rear of the jet injection.

  • PDF

Pain control using the Point-Inject Technique in dental local anesthesia (Point Inject Technique을 이용한 치과 국소마취의 통증 조절 및 진료 효율의 극대화)

  • Lee, Jae-youn;Choe, Sunga
    • Journal of Korean Academy of Dental Administration
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • Many approaches to local anesthesia have been studied in dentistry. In this study, we introduce a new local anesthetic method, "Point-Inject Technique (PIT)", and compare it with traditional injection techniques. The PIT method utilizes both the vasoconstrictive and antinociceptive properties of local anesthetics as well as the application of controlled pressure during injection, reducing the time to complete anesthesia. Fifty patients were selected as the experimental group who were anesthetized using PIT, and the other 50 patients were selected as the control group using the direct injection method with a carpool syringe. The PIT group received 0.25 cartridges of 2% lidocaine with 1:100,000 epinephrine. The control group received 1.5~2 cartridges of 2% lidocaine with 1:100,000 epinephrine. Both groups were asked to mark the intensity of the pain caused by anesthesia using the Numeric Pain Rating Scale. The average time to recover from anesthesia was 40 minutes in the experimental group and 90 minutes in the control group. Additionally, 96% of the experimental group reported feeling no pain, while 78% of the control group reported having some form of pain during injection. The PIT method reduced both the reported pain scores of patients as well as time to recover from local anesthesia than the widely-used syringe injection method.

Experimental Study on Spray Structure of a High Pressure 6-Hole Injector by Mie Scattering Technique (미산란 기법에 의한 고압 6공 연료분사기의 분무형상에 대한 실험적 연구)

  • Kim, Seong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.878-883
    • /
    • 2008
  • The spray characteristics of a high pressure 6-hole injector were examined in a single cylinder optical direct injection spark ignition (DISI) engine. The effects of injection timing, in-cylinder charge motion, fuel injection pressure and coolant temperature were investigated using the 2-dimensional Mie scattering technique. It was confirmed that the in-cylinder charge motion played a major role in the fuel spray distribution during the induction stroke while the propagation of fuel spray was restrained during the compression stroke by the increasing pressure and the upward moving piston. In additions, it was confirmed that the liquid fuel droplets existing at the sprays edges were vaporized by the increase of the coolant temperature.

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF