• 제목/요약/키워드: Injection conditions

검색결과 1,819건 처리시간 0.035초

Determination of Uric Acid by Chemiluminescence Measurement Using Tris(2,2'-bipyridine)ruthenium(II)-Octylphenylpolyglycol Ether System

  • Kim, Young-Sang;Park, Jeung-Hee;Choi, Yoon-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권8호
    • /
    • pp.1177-1181
    • /
    • 2004
  • The determination of uric acid in urine samples was studied by a chemiluminescence measurement using tris (2,2'-bipyridine)ruthenium(II)-octylphenylpolyglycolether [Ru$(bpy)_3^{2+}$ -OPE] system. The oxidized uric acid by Ce(IV) excited Ru$(bpy)_3^{2+}$ to emit a chemiluminescence in this system so that the intensity was stoichio-metrically dependent upon the concentration of uric acid. In a reaction cell, a luminescent reagent, oxidant, surfactant and sulfuric acid were flowed into and mixed with a taken sample. Experimental conditions were optimized to obtain the maximum intensity of chemiluminescence. Each reactant solution of more than the following concentration gave a good result: $2\;{\times}\;10^{?4}$ M Ru$(bpy)_3^{2+}$ , 0.01 M Ce(IV), 6% OPE, and 0.33 M $H_2SO_4$. Any interferences were not shown in this process by the investigation of concomitant constitutes such as albumin, creatine, lactic acid, glucose, urea, $Cl^?,\; Mg^{2+},\;Ca^{2+}$ and so on. The linearity of a calibration curve was good with r = 0.998, the relative standard deviation of the slope was 3.3% and the detection limit was 5.6ng/mL. The recoveries of 80 to 91% were obtained from the standard spiked samples. The values were little bit low, but this procedure could be considered to be reliable for the determination of trace uric acid in urine samples.

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.

Experimental Investigations on Upper Part Load Vortex Rope Pressure Fluctuations in Francis Turbine Draft Tube

  • Nicolet, Christophe;Zobeiri, Amirreza;Maruzewski, Pierre;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.179-190
    • /
    • 2011
  • The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The influence of outlet bubble cavitation and air injection is also investigated for low cavitation number. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

300MW급 Shell형 1단 분류층 석탄 가스화기의 전산수치해석 : 산소/스팀/석탄 주입비, 석탄입자 크기, 주입 노즐 각도가 가스화기 성능에 미치는 영향 (CFD Modeling for 300MW Shell-Type One-Stage Entrained Flow Coal Gasifier : Effect of $O_2$/Steam/Coal Ratios, Coal Particle Sizes, and Inlet Angles on the Gasifier Performance)

  • 송지훈;강민웅;서동균;임성진;백민수;황정호
    • 한국수소및신에너지학회논문집
    • /
    • 제21권3호
    • /
    • pp.227-240
    • /
    • 2010
  • Coal gasification is heading for a great future as one of the cleanest energy sources, which can produce not only electricity and heat, but also gaseous and liquid fuels from the synthesis. The work focuses on 300MW shell type one-stage entrained flow coal gasifier which is used in the Integrated coal Gasification Combined Cycle(IGCC) plant as a reactor. As constructing an IGCC plant is considerably complicated and expensive compared with a pulverized-coal power plant, it is important to determine optimum design factors and operating conditions using a computational fluid dynamics (CFD) model. In this study, the results of numerical calculations show that $O_2$/Coal ratio, 0.83, Steam/Coal ratio, 0.05, coal particle diameter, $100{\mu}m$, injection angle, $4^{\circ}$ (clockwise) are the most optimum in this research.

전극 변화에 따른 유기 발광 소자의 내장 전압 (Built-in voltage depending on electrode in organic light-emitting diodes)

  • 윤희명;이은혜;이원재;정동회;오용철;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집
    • /
    • pp.14-16
    • /
    • 2008
  • Built-in voltage in organic light-emitting diodes was studied using modulated photocurrent technique ambient conditions. From the bias voltage-dependent photocurrent, built-in voltage of the device is determined. The applied bias voltage when the magnitude of modulated photocurrent is zero corresponds to a built-in voltage. Built-in voltage in the device is generated due to a difference of work function of the anode and cathode. A device was made with a structure of anode/$Alq_3$/cathode to study a built-in voltage. ITO was used as an anode, and Al and LiAl were used as a cathode. A layer thickness of Al and LiAl were 100nm. Obtained built-in voltage is about 1.0V in the Al layer was used as a cathode. The obatined built-in voltage is about 1.6V in the LiAl layer was used as a cathode. The result of built-in voltage is dependent of cathode. We can see that the built-in voltage increase up to 0.4V when the LiAl layer was used as the cathode. These results correspond to the work function of LiAl which is lower than that of Al. As a result, the barrier height for an electron injection from the cathode to the organic layer could be lowered when the LiAl was used as a cathode.

  • PDF

Patterns of Plasma Fatty Acids in Rat Models with Adenovirus Infection

  • Paik, Man-Jeong;Park, Ki-Ho;Park, Joong-Jean;Kim, Kyoung-Rae;Ahn, Young-Hwan;Shin, Gyu-Tae;Lee, Gwang
    • BMB Reports
    • /
    • 제40권1호
    • /
    • pp.119-124
    • /
    • 2007
  • Adenoviral vectors are among the most promising vectors available for human gene therapy. However, the use of recombinant adenoviral vectors, including replicationcompetent adenovirus (RCA), raises a variety of safety concerns in relation to the development of new therapies based on gene therapy. To examine how organic compounds change in rat plasma following the injection of adenovirus, $\beta$-galactosidase expressing recombinant adenovirus (designated rAdLacZ) or RCA, we investigated the content of fatty acids (FAs), which are important biochemical indicators in pathological conditions. Pattern recognition analysis on the level of FAs in rat plasma is described for the visual discrimination of adenovirus infection groups from normal controls. Plasma FAs from four control rats (normal group), and from four rats with rAdLacZ infection and six rats with RCA infection (the two abnormal groups), were examined by gas chromatography-mass spectrometry in selected ion monitoring modes as their tert-butyldimethylsilyl derivatives. In total, 20 FAs were positively detected and quantified. The results of the Student's t-test on the normal mean of two abnormal groups, the levels of three FAs (p<0.05) from rAdLacZ group and eleven FAs (p<0.05) from RCA group were significantly different. When star symbol plotting was applied to the group mean values of 20 FAs after normalization to the corresponding normal mean values, the resulting eicosagonal star patterns of the two infected groups were distorted into similar shapes, but were distinguishable from each other. Thus, these approaches will be useful for screening and monitoring of diagnostic markers for the effects of infection following the use of adenoviral vectors in gene therapy.

축소형 초고압 분사 시스템의 노즐 형상에 따른 초음속 액체 제트 분무 특성에 관한 연구 (Spray Characteristics of Supersonic Liquid Jet by a Nozzle Geometry of Miniature High-Pressure Injection System)

  • 신정환;이인철;김희동;구자예
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.177-180
    • /
    • 2010
  • 고압관, 가압관, 발사관으로 구성된 Ballistic Range의 일종인 2단식 경가스 총을 사용하여 초음속 액체 제트의 분무 특성을 연구하였다. 135 bar의 압축공기는 고압관과 가압관 사이에 OHP필름으로 구성된 격막을 파열시킨 후 가압관의 발사체를 약 250 m/s의 속도로 가속하였다. 가속된 발사체는 액체 저장부에 충돌하여 액체를 초고압으로 가압한 후 초음속으로 분사시키며, 특히 초음속 액체 제트는 미립화된 다중 제트의 형태를 나타내고 액체 제트 전방 영역에서 충격파를 수반한다. 다양한 분사 노즐의 기하학적 형상에 대한 분무시험결과 초음속 액체 제트의 속도와 충격파 각도가 각각 다르게 생성되었으며, L/d가 9.9, 11.9, 23.8의 조건에 대하여 L/d가 23.8의 경우에 액체 제트의 분사속도가 마하수 1.53으로 가장 낮게 측정되었다.

  • PDF

전단 동축형 인젝터를 통해 분사된 기체메탄-기체산소 확산화염의 연소특성 (Combustion Characteristics of a Gaseous Methane-Gaseous Oxygen Diffusion Flame Sprayed by a Shear Coaxial Injector)

  • 홍준열;배성훈;권오채;김정수
    • 한국추진공학회지
    • /
    • 제21권3호
    • /
    • pp.41-48
    • /
    • 2017
  • 전단 동축형 인젝터를 통해 분사된 친환경 이원추진제 기체메탄-기체산소의 연소특성을 규명하기 위한 연구를 수행하였다. DSLR카메라를 이용하여 다양한 연소조건에서 화염을 촬영하였고, 이미지 후처리 기법을 통해 화염형상을 정량화한 후 그 특성을 분석하였다. 안정화 관점에서 확산화염은 anchored flame regime과 blow-off regime으로 구분될 수 있었으며, 산화제 레이놀즈 수($Re_o$)가 증가함에 따라 부착화염의 형성, 화염의 길이가 증가하는 경향을 나타냈다. 본 실험에 이용된 전단 동축형 인젝터는 추진제 제트의 운동량 확산에만 종속하고 그리 양호하지 않은 혼합으로 인해 분사방향으로 길이가 긴 화염을 형성하게 되므로 보다 큰 연소실 길이직경비가 요구됨을 확인할 수 있었다.

터널굴착용 투입형 연마재 워터젯 시스템의 연마재 투입량과 유동성에 미치는 영향 인자 (Influencing factors for abrasive flow rate and abrasive flow quality of abrasive injection waterjet systems for tunnel excavation)

  • 주건욱;오태민;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제16권4호
    • /
    • pp.417-430
    • /
    • 2014
  • 도심지 내 지하공간의 효율적인 활용을 위해서 연마재 워터젯 시스템(abrasive waterjet system)을 이용한 새로운 형태의 암반굴착 공법이 개발되어 활용 중에 있다. 연마재 워터젯 시스템을 활용한 굴착(절삭) 수행 시 적정량의 연마재를 투입하고 연마재입자의 유동성을 원활하게 유지하는 것은 매우 중요하다. 본 연구에서는 실내실험을 통해 연마재 입자의 유동성과 관련된 영향인자들을 연마재 관 설치높이, 연마재 관 길이, 연마재 관 굴곡도 그리고 연마재 관 내경으로 나누어 연마재 투입량 및 유동성 수준을 평가하였다. 또한, 실험결과를 바탕으로 연마재 투입량 및 연마재 입자 유동성에 관한 최적 조건을 제시하였다. 본 연구결과를 바탕으로 향후 암반 굴착용 워터젯 공법이 도심지 내 터널, 공동구, 수직구 건설 등 다양한 지반 구조물 굴착 작업 시, 최적 연마재 투입을 위한 기초자료로 유용하게 활용될 수 있을 것으로 기대된다.

유발지진 관측과 활용 (Induced Seismicity and Its Applications)

  • 강태섭;이준기;최남수
    • 지구물리와물리탐사
    • /
    • 제18권1호
    • /
    • pp.21-30
    • /
    • 2015
  • 유발지진은 인류에 의한 수많은 영향 및 다양한 지질학적 조건과 연관되어서 지난 수십 년 동안 관측되어 왔다. 이 논문에서는 다양한 유발지진을 고찰하고 자연적인 조구조 지진뿐만 아니라 유발지진의 종류에 따라 서로 비교한다. 수압파쇄는 암석층에서 새로운 균열을 통해 투수성을 높이는데 보편적으로 사용된다. 이 과정에서 유발지진이 발생하는데, 이 지진은 단열망과 석유/가스의 이동에 관한 중요한 정보를 제공한다. 유사한 방식으로 탄화수소 생산과정이나, 댐 저수지, 채광 활동 또는 폐수 주입 등의 과정에서도 의도하지 않은 유발지진이 발생하며, 이를 이용하여 다양한 수리역학적인 과정과 다양한 규모에서 저류층 특성의 변화를 파악할 수 있다. 일반적인 결론으로 지금까지 알려진 유발지진에 대한 불확실성과 지식의 한계를 요약하고 향후 연구에서 다루어야 할 몇 가지 주제를 제시한다.