Abstract
The determination of uric acid in urine samples was studied by a chemiluminescence measurement using tris (2,2'-bipyridine)ruthenium(II)-octylphenylpolyglycolether [Ru$(bpy)_3^{2+}$ -OPE] system. The oxidized uric acid by Ce(IV) excited Ru$(bpy)_3^{2+}$ to emit a chemiluminescence in this system so that the intensity was stoichio-metrically dependent upon the concentration of uric acid. In a reaction cell, a luminescent reagent, oxidant, surfactant and sulfuric acid were flowed into and mixed with a taken sample. Experimental conditions were optimized to obtain the maximum intensity of chemiluminescence. Each reactant solution of more than the following concentration gave a good result: $2\;{\times}\;10^{?4}$ M Ru$(bpy)_3^{2+}$ , 0.01 M Ce(IV), 6% OPE, and 0.33 M $H_2SO_4$. Any interferences were not shown in this process by the investigation of concomitant constitutes such as albumin, creatine, lactic acid, glucose, urea, $Cl^?,\; Mg^{2+},\;Ca^{2+}$ and so on. The linearity of a calibration curve was good with r = 0.998, the relative standard deviation of the slope was 3.3% and the detection limit was 5.6ng/mL. The recoveries of 80 to 91% were obtained from the standard spiked samples. The values were little bit low, but this procedure could be considered to be reliable for the determination of trace uric acid in urine samples.
Keywords
Chemiluminescence method; Uric acid; Flow injection; Tris(2,2'-bipyridine)ruthenium(II); Urine;
Citations & Related Records

Times Cited By Web Of Science : 2  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 Imdadullah, Terufumi F.; Takahiro, K. Anal. Chem. 1991, 63,2348.   DOI
2 Qun, F.; Xiao-Tong, S.; Yu-Qing, S.; Zhao-Lun, F. Anal. Chem.1997, 69, 3570.   DOI   ScienceOn
3 Nobutoshi, K.; Hidekazu, K.; Motohisa, F. Anal. Sci. 1995, 11,605.   DOI   ScienceOn
4 Kazuichi, H.; Tsuyoshi, M.; Mizuka, B.; Motoichi, M. Environ.Sci. Tech. 1995, 29, 928.   DOI   ScienceOn
5 Tadashi, H.; Syuji, K.; Hishshi, N.; Riichiro, N. Anal. Sci. 1994,10, 223.   DOI   ScienceOn
6 Li, Z.; Feng, M.; Lu, J. Microchem. J. 1998, 59, 278.   DOI   ScienceOn
7 Wei, Q.; Zhuhun, Z.; Huajun, L. Anal. Chem. 1998, 70, 3579.   DOI   ScienceOn
8 Ryoya, G.; Kohsuke, K.; Tomot.fumi, S.; Takeshi, F. Anal. Sci.1996, 12, 713.   DOI   ScienceOn
9 Bo, H.; Jian-j, L.; Le, Z.; Jie-ke, C. Anal. Chem. 1996, 68, 2366.   DOI   ScienceOn
10 Kuimala, S.; Ala-Kleme, T.; Papkovsky, D.; Loikas, K. Anal.Chem. 1998, 70, 1112.   DOI   ScienceOn
11 Juana, C.; Manuel, S.; Dolores, P. Anal. Chem. 1995, 67, 4376.   DOI
12 Pablo, P.; Romofumi, S.; Hiroshi, H.; Kazuhiro, I. Anal. Sci. 1995,11, 575.   DOI   ScienceOn
13 Mitsuhiro, W.; Naotaka, K.; Toshihiko, I.; Shuzo, A.; Kenichiro,N. Anal. Sci. 1996, 12, 807.   DOI   ScienceOn
14 Theingi, K.; Terufumi, F.; Fidekazu, I.; Yasuaki, O.; Takahiro, K.Anal. Sci. 1998, 14, 203.   DOI   ScienceOn
15 Kazuhiko, T.; Masayuki, S.; Riichiro, N.; Masamichi, N.; Mizuo,M. Anal. Sci. 1998, 14, 409.   DOI   ScienceOn
16 Kazunori, I.; Hideaki, W.; Isao, K. Biosensor 1996, 11, 959.
17 Jinchun, Y.; Alan, M. S. Anal. Chem. 1999, 71, 1975.   DOI   ScienceOn
18 Kenichiro, N.; Naoko, H.; Shinki, K.; Shuzo, A.; Yukie, T.;Kazuhiro, I. Anal. Sci. 1991, 7, 715.   DOI
19 Takashi, H.; Junko, N.; Takuji, K. Anal. Sci. 1997, 13, 93.
20 Burtist, C. A.; Ashwood, E. R. Tietz Textbook of ClinicalChemistry; 2nd ed.; WB Saunders Company: Philadelphia, 1994;p 1539.
21 Kazuhiko, T.; Shigehiro, F.; Riichiro, N. Anal. Sci. 1997, 13, 279.