• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.028 seconds

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

A Study on the Impermeable Effect by Grouting in the Subsea Tunnel (해저터널에서 주입에 의한 차수효과 연구)

  • Kim, Seunghwan;Lim, Heuidae;Yoon, Seongmin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.6
    • /
    • pp.5-19
    • /
    • 2017
  • In this study, the effect of rock mass curtain grouting was investigated by analyzing the correlation between the parameters of the RMR & grout injection volume, Lugeon value & RQD, Lugeon value & cement injection volume. In order to investigate the effect of rock mass curtain grouting, we analyzed the grout injection volume of 315 curtain grouting holes at 9 tunnel face of NATM Subsea tunnels in gneiss area. The total grout injection volume in the Subsea tunnels study was slightly changed in some tunnels face but decreased with increasing the rating of parameters in spacing of discontinuity (R3, Js) and groundwater condition (R5). The geological anomalies of seismic survey (3D, TSP) and the inflow of probe hole were found to be more correlated of relative than the parameters of RMR. The unit injection volume was found to decrease with higher ratings in the parameters of the RMR except the weathering degree of the discontinuity (Jc, R4). The correlation between RQD and Lugeon values is not significant, but it can be confirmed that the Lugeon value tends to decrease as the RQD value increases.

Novel anatomical proposal for botulinum neurotoxin injection targeting depressor anguli oris for treating drooping mouth corner

  • Kyu-Ho Yi;Ji-Hyun Lee;Hye-Won Hu;You-Jin Choi;Kangwoo Lee;Hyung-Jin Lee;Hee-Jin Kim
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.161-165
    • /
    • 2023
  • The depressor anguli oris (DAO) muscle is a thin, superficial muscle located below the corner of the mouth. It is the target for botulinum neurotoxin (BoNT) injection therapy, aimed at treating drooping mouth corners. Hyperactivity of the DAO muscle can lead to a sad, tired, or angry appearance in some patients. However, it is difficult to inject BoNT into the DAO muscle because its medial border overlaps with the depressor labii inferioris and its lateral border is adjacent to the risorius, zygomaticus major, and platysma muscles. Moreover, a lack of knowledge of the anatomy of the DAO muscle and the properties of BoNT can lead to side effects, such as asymmetrical smiles. Anatomical-based injection sites were provided for the DAO muscle, and the proper injection technique was reviewed. We proposed optimal injection sites based on the external anatomical landmarks of the face. The aim of these guidelines is to standardize the procedure and maximize the effects of BoNT injections while minimizing adverse events, all by reducing the dose unit and injection points.

CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium (토끼 뇌감염 모델의 CT 소견과 조영제 주입 후 동맥혈의 Hounsfield Unit의 변화)

  • Ha, Bon-Chul;Kwak, Byung-Kook;Jung, Ji-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.270-279
    • /
    • 2012
  • This paper explores CT findings of a rabbit brain infection model injected with Escherichia coli and investigates the changes in Hounsfield unit (HU) of arterial blood over time. The brain infection model was produced by injecting E. coli $1{\times}10^7$ CFU/ml, 0.1 ml through the burr hole in the calvarium; 2~3 mm in depth from the dura mater, and contrast-enhanced CT, dynamic CT and arterial blood CT images were gained. It was found that various brain infections such as brain abscess, ventriculitis and meningitis. The CT image of brain abscess showed a typical pattern which the peripheral area was strongly contrast-enhanced while the center was weakly contrast-enhanced. The CT image of ventriculitis showed a strong contrast-enhancement along the lateral ventricle wall, and the CT image of meningitis showed a strong contrast-enhancement in the area between the telencephalon and the diencephalon. In dynamic CT images, the HU value of the infection core before injecting contrast medium was $31.01{\pm}3.55$. By 10 minutes after the injection, the value increased gradually to $40.36{\pm}3.76$. The HU value in the areas of the marginal rim where was hyper-enhanced showed $47.23{\pm}3.12$ before contrast injection, and it increased to $63.59{\pm}3.31$ about 45 seconds after the injection. In addition, the HU value of the normal brain tissue opposite to the E. coli. injected brain was $39.01{\pm}3.24$ before the injection, but after the contrast injection, the value increased to $49.01{\pm}4.29$ in about 30 seconds, and then it showed a gradual decline. In the arterial blood CT, the HU value before the contrast injection was $87.78{\pm}6.88$, and it increased dramatically between 10 to 30 seconds until it reached a maximum value of $749.13{\pm}98.48$. Then it fell sharply to $467.85{\pm}62.98$ between 30 seconds to 45 seconds and reached a plateau by 60 seconds. Later, the value showed a steady decrease and indicated $188.28{\pm}25.03$ at 20 minutes. Through this experiment, it was demonstrated that the brain infection model can be produced by injecting E. coli., and the characteristic of the infection model can be well observed with contrast-enhanced CT scan. The dynamic CT scan showed that the center of the infection was gradually contrast-enhanced, whereases the peripheral area was rapidly contrast-enhanced and then slowly decreased. As for arterial blood, it increased significantly between 10 seconds to 30 seconds after the contrast medium injection and decreased gradually after reaching a plateau.

An Experimental Study on Artificial Infection of Olive Flounder Paralichthys olivaceus by Streptococcus parauberis Using Different Injection Sites (넙치(Paralichthys olivaceus)의 Streptococcus parauberis 인위감염을 위한 공격실험 방법에 관한 연구)

  • Kim, Tae-Ho;Lee, Nam-Sil;Choi, Hye-Sung;Jung, Sung-Hee;Han, Hyun-Ja
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.4
    • /
    • pp.628-636
    • /
    • 2020
  • Streptococcosis in the olive flounder Paralichthys olivaceus can be caused by Streptococcus parauberis. We compared three routes of administration for experimental injections of the S. parauberis 19FBSPa0003 strain in the olive flounder. Pathological changes were observed during the experimental infection. Inflammation of the serous membrane in the liver, intestine, spleen and heart was the major pathological change found in the infected olive flounder. No mortality was observed in fish that received intraperitoneal (IP) injection at less than 1×104 colony-forming unit (CFU)/fish. The lethal dose 50 for olive flounder, given an intravenous (IV) injection, was 7.94×104 CFU/fish. Fish with a higher concentration of IV injected S. parauberis (1×108 CFU/fish) died within a maximum of two days. However, serious necrosis and bacterial proliferation in ellipsoidal cells of the spleen and heart tissues were found in moribund or dead fish, 1-2 days after IV injection. Similar histopathological signs were observed in olive flounder inoculated by subcutaneous (SC) infected and naturally infected. In addition, SC was also strongly associated with bacteria concentration and cumulative mortality rate. Based on these results, SC is the recommended method for artificial infection by S. parauberis in the olive flounder.

Hydrogen Jet Structure and Measurement of Local Equivalence Ratio by LIBs under the Different Injection Pressure (분사 압력에 따른 수소 제트의 형상과 LIBs를 적용한 국부 당량비 계측)

  • Lee, Sanguk;Kim, Jungho Justin;Bae, Choongsik
    • Journal of ILASS-Korea
    • /
    • v.27 no.2
    • /
    • pp.84-93
    • /
    • 2022
  • To implement carbon-neutrality in transportation sectors until 2050, hydrogen is considered a promising fuel for internal combustion engines because hydrogen does not contain carbon itself. Although hydrogen does not emit CO2 emission from its combustion process, the low energy density in a volume unit hinders the adoption of hydrogen. Therefore, the understanding of hydrogen jet behavior and measurement of equivalence ratio must be conducted to completely implement the high-pressure hydrogen direct injection. The main objective of this research is feasibility test of hydrogen local equivalence ratio measurement by laser-induced breakdown spectroscopy (LIBs). To visualize the macroscopic structure of hydrogen jet, high-speed schlieren imaging was conducted. Moreover, LIBs has been adopted to validate the feasibility of hydrogen local equivalence ratio measurement. The hydrogen injection pressure was varied from 4 MPa to 8 MPa and injected in a constant volume chamber where the ambient pressure was 0.5 MPa. The increased injection pressure extends the vertical penetration of hydrogen jet. Due to the higher momentum supply when the injection pressure is high, the hydrogen has easily diffused in all directions. As the laser trigger timing has delayed, the low hydrogen atomic emission was detected due to the longer mixture formation time. Based on equivalence ratio measurement results, LIBs could be applied as a methodology for hydrogen local equivalence ratio measurement.

Effects on hematology and blood biochemistry profile of intramuscular meloxicam injection in Brahminy kite and Barn owl

  • Ratiwan Sitdhibutr;Raveewan Ploypan;Sirawit Subaneg;Chaiyan Kasorndorkbua
    • Journal of Veterinary Science
    • /
    • v.24 no.3
    • /
    • pp.43.1-43.8
    • /
    • 2023
  • Background: Meloxicam is used widely for exotic animal analgesia, but its toxicity in common raptor species in Thailand is unclear. Objectives: This study evaluated the single-dose effect of intramuscular meloxicam in common raptor species in Thailand for short-term and long-term periods. Methods: Twenty-two raptors were administered a single 1 mg/kg dose of meloxicam individually via intramuscular injection. The following were evaluated: clinical appearance, body weight, body condition score, body temperature, fecal appearance, complete blood cell count, and biochemistry panel before (day 0) and after the injection (1, 7, and 30 days). The collected samples were categorized into three groups: Brahminy kite (Haliastur indus) (n = 10), adult Barn owl (Tyto javanica) (n = 4), and juvenile Barn owl (n = 8). Results: None of the raptors in the study groups showed any abnormalities. The hematological profiles were significantly different in the short-term period (day 1 and day 7). The creatinine, aspartate aminotransferase, and creatinine kinase increased in several groups. On the other hand, the packed cell volume decreased in the Brahminy kite and juvenile Barn owl groups. According to the findings, an intramuscular injection of 1 mg/kg meloxicam affected the blood biochemistry panel of the muscle, but the affected raptors recovered within one week. Conclusions: An intramuscular injection of meloxicam at a single 1 mg/kg dose in Brahminy kites and Barn owls was not associated with the morbidity, hepatotoxicity, gastrointestinal toxicity, and nephrotoxicity in the short- and long-term periods.

Pain Reducing Effects of Dextrose-coated Pacifier on Venipuncture in Premature Infants (포도당 코팅 노리개 젖꼭지 제공이 미숙아의 정맥주사 시 통증 반응에 미치는 효과)

  • Seo, Jung-Suk;Kwon, In-Soo;Kim, Hee;Jung, Young-Ran;Jo, Sung-Jin;Hwang, Ju-Young;Kang, Hyun-Sun
    • Korean Parent-Child Health Journal
    • /
    • v.13 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the pain reducing effects of the dextrose-coated pacifier on venipuncture in premature infants. Methods: The design of this study is a nonequivalent control group pretest-posttest design and a crossover trial. The analysed cases were 40 premature infants (20 in experimental group and 20 in control group) in neonatal intensive care unit of a University Hospital, Gyeongnam Province, Korea. The data were collected from April to October, 2009. The experimental treatment was carried out nursing 20% dextrose-coated pacifier on venipuncture for IV injection. The instruments were $O_2$ saturation and heart rate on pulse oxymeter monitor to measure physiologic pain responses, and NIPS to measure behavioral pain responses. Collected data were analyzed with $x_2$ test, t-test using SPSS program. Results: The effects of the 20% dextrose-coated pacifier were found in the physiologic (only heart rate) and behavioral pain response on venipuncture. Conclusion: These finding is suggested that the dextrose-coated pacifier could be an effective nursing intervention for reducing pain on venipuncture in premature infants.

  • PDF

Multiple-Axes Velocity-Synchronizing Control of AC-Servomotor Load System for Injection Process (사출공정을 위한 AC 서보모터-부하계의 다축 속도 동기제어)

  • Jon, Yun-Son;Jung, Kwon;Choi, Jang Hoon;Ahn, Hyun;Lee, Hyeong Cheol;Kim, Young Shin;Hong, Seong Ho;Cho, Seung Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.8
    • /
    • pp.719-726
    • /
    • 2015
  • This paper presents a velocity-synchronizing control for the multiple axes of an injection unit; based on MBS, a virtual design model has been developed for the multiple-axes servomechanism. Prior to the design of the controller, a linear plant model was derived via open-loop response simulations. To synchronize the motions of the multiple axes, a cross-type synchronizing controller was designed and combined with the PID control to accommodate any parameter mismatches among the multiple axes. From the tracking control simulations, a significant reduction of both velocity-tracking and position-tracking errors was achieved through the use of the proposed control scheme.

Yellow Light-Emitting Poly(p-phenylenevinylene) Derivative with Balanced Charge Injection Property

  • Kim, Joo-Hyun;Lee, Hoo-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.652-656
    • /
    • 2004
  • A new luminescent polymer, poly{1,4-phenylene-1,2-ethenediyl-2'-[2"-(4'"-octyloxyphenyl)-(5"-yl)-1",3",4"-oxadiazole]-1,4-phenylene-1,2-ethenediyl-2,5-bis-dodecyloxy-1,4-phenylene-1,2-ethenediyl} (Oxd-PPV), was synthesized by the Heck coupling reaction. Electron withdrawing pendant, conjugated 1,3,4-oxadiazole (Oxd), is on the vinylene unit. The band gap of the polymer figured out from the UV-visible spectrum was 2.23 eV and the polymer film shows bright yellow emission maximum at 552 nm. The electroluminescence (EL) maximum of double layer structured device (ITO/PEDOT:PSS/Oxd-PPV/Al) appeared at 553 nm. Relative PL quantum yield of Oxd-PPV film is 3.6 times higher than that of MEH-PPV film. The HOMO and LUMO energy levels of Oxd-PPV figured out from the cyclic voltammogram and the UV-visible spectrum are -5.32 and -3.09 eV, respectively, so that more balanced hole and electron injection efficiency can be expected compared to MEH-PPV. A double layer EL of Oxd-PPV has an maximum efficiency of 0.15 cd/A and maximum brightness of 464 cd/$m^2$.