• Title/Summary/Keyword: Injection Site

Search Result 559, Processing Time 0.034 seconds

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

Treatment of gummy smile using botulinum toxin: a review (보툴리눔 독소를 이용한 치은과다노출증의 치료 고찰)

  • Myung, Yangho;Woo, Keoncheol;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.2
    • /
    • pp.61-72
    • /
    • 2021
  • A beautiful smile is made when it is symmetrical and gums are displayed less than 2 - 3 mm. Excessive gingival display also known as "gummy smile" is often recognized to be unaesthetic. Causes of gummy smile can be caused by delayed eruption, vertical maxillary excess, hypermobile upper lip, or a short upper lip. Meanwhile botulinum toxin which is an exotoxin produced from Clostridium botulinum, works by blocking the release of acetylcholine from the cholinergic nerve end plates leading to inactivity of the muscles. The application site and weakens the muscle tone is drawing attention as a gummy smile treatment caused by hypermobile upper lip. There have been many studies about the method of injecting botulinum toxin into muscles around the lips, but there is still no standardized research method and treatment method, so there is controversy over the therapeutic effect. The aim of this study is to review the previous studies about the predictors of indication and effects of gummy smile treatment using botulinum toxin injection. Especially we tried to propose a protocol for optimal dose and efficient injection point through the anatomical considerations for gummy smile treatment using botulinum toxin.

Evaluation of Skin Irritation and Sensitization on an Acaricide Containing Essential Oils of Chamaecyparis obtusa and Cinnamomum camphora for Control of Poultry Red Mite (Dermanyssus gallinae) (편백정유와 계피정유를 주성분으로 한 닭진드기 살비제에 대한 피부 자극성 및 감작성 평가)

  • Song, Jun-Ho;Hwang, Du Hyeon;Kim, Euikyung;Kim, Suk;Lee, Hu-Jang
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • This evaluation tested the skin irritation and sensitization of an acaricide (Wagoojabi II®, WGJB) for the control of poultry red mite, containing 20% Chamaecyparis obtusa oil and 56% Cinnamomum camphora oil. In a primary skin irritation test, rabbits were dermally treated with WGJB for 24 h. The acaricide did not induce any adverse reactions such as erythema and edema on intact skin sites, but on abraded skin sites, some rabbits showed very slight erythema and edema 24 h after topical application. So, the acaricide was classified as a practically mild-irritating material based on a 0.625 primary irritation index score. In the skin sensitization test, guinea pigs were sensitized with intradermal injection of 0.1mL WGJB for 24 h. After 1 week, The WGJB was treated on the site of injection, and challenged 2 weeks later. The WGJB did not induce any allergic reactions. Therefore, the WGJB was graded as a weak material at '0' in both sensitization score and rate. From the results of this study, it is suggested that WGJB does not cause contact irritation and sensitization.

A field study on early stabilization of waste landfill using air injection and leachate recirculation (공기주입과 침출수 재순환 방법을 이용한 폐기물 매립지 조기안정화에 관한 현장 실험 연구)

  • Yoon, Seok-Pyo;Zhao, Xin;Lee, Nam-Hoon;Jeon, Yeon-Ho;Byun, Young-Deog;Ahn, Young-Mi;Min, Ji-Hong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.45-54
    • /
    • 2010
  • Field study was conducted for 5 months to investigate the effect of leachate recirculation on aerobic landfill stabilization at active landfilling site. The area of field experiment was $24{\times}24m$ and 9 vertical air injection wells with screen ranging 3~9 m were installed. Aerobic landfill operation for 5 months increased average internal landfill temperature to $70^{\circ}C$ and 8 % of landfill height was settled down. $94m^3$ of leachate was recirculated for 1 month to increase moisture content of landfill to favor microbial degradation of organic matter, which resulted in temporary increase of groundwater level and anaerobic environment. But leachate recirculation triggered increase of internal landfill temperature of neighboring monitoring well. Because excessive leachate recirculation decreased internal landfill temperature by cooling effect, internal landfill temperature should be checked to avoid abrupt decrease of temperature during leachate recirculation. Also, to prevent anaerobic environment, intermittent leachate recirculation was recommended.

Horizontal 2-D Finite Element Model for Analysis of Mixing Transport of Heat Pollutant (열오염 혼합 거동 해석을 위한 수평 2차원 유한요소모형)

  • Seo, Il Won;Choi, Hwang Jeong;Song, Chang Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.507-514
    • /
    • 2011
  • A numerical model has been developed by employing a finite element method to simulate the depth-averaged 2-D dispersion of the heat pollutant, which is an important pollutant material in natural streams. Among the finite element methods, the Streamline Upwind/Petrov Galerkin (SUPG) method was applied. Also both linear and quadratic elements can be applied so that irregular river boundaries can be easily represented. To show the movement of heat pollutants, the reaction term describing heat transfer was represented as an equation in which sink/source term is proportional to the difference between the equilibrium temperature and water surface temperature. The equation was expressed so that the water surface temperature changes according to the temperature transfer coefficient and the equilibrium temperature. For the calibration of the model developed, analytic and numerical results from a case of rectangular channel with full width continuous injection have been compared in a steady state. The comparisons showed that the numerical results were in good agreement with analytical solutions. The application site was selected from the downstream of Paldang dam to Jamsil submerged weir, and overall length of this site is about 22.5 km. The change of water temperature caused by the discharge from the Guri sewage treatment plant has been simulated, and results were similar to the observed data. Overall it is concluded that the developed model can represent the water temperature changes due to heat transport accurately. But the verification using observed data will further enhance the validity of the model.

Iron and Manganese Removal through Well Development at River Bank Filtration Site (강변여과수 개발지역 우물 개량시 철망간 저감 효과)

  • Kim, Gyoo-Bum;Kim, Byung-Woo;Shin, Seon-Ho;Park, Joon-Hyeong
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.389-400
    • /
    • 2009
  • Iron and manganese contents are usually over the limit of drinking water standard (0.3 mg/L) in unconsolidated aquifer of river bank filtration site in Nakdong river. Surge block and air surging techniques used in this study are useful tools to remove the slime within gravels and pebbles, to increase permeability of aquifer, to provide oxygen into aquifer, and to discharge iron and manganese oxides from a well. Surging activity brought about $5{\sim}8$ and $5{\sim}9$ times decreases in $Fe_{(total)}$ and $Fe^{2+}$ contents, and also 10 times decrease in $Mn^{2+}$ contents compared to non-surging condition, respectively. Additionally, iron oxide and manganese oxide increased up $1{\sim}1.2$ times after surging. This result shows that air injection into the aquifer can help iron and manganese content decreased and in-situ treatment technology needs to be introduced in river bank filtration project in South Korea.

Hydrogeological Stability Study on the Underground Oil Storage Caverns by Numerical Modeling (수치모델링을 이용한 지하원유비축시설의 수리지질학적 안정성 연구)

  • 김경수;정지곤
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.35-51
    • /
    • 2002
  • This study aims to establish the methodology for design of an optimum water curtain system of the unlined underground oil storage cavern satisfying the requirements of hydrodynamic performance in a volcanic terrain of the south coastal area. For the optimum water curtain system in the storage facility, the general characteristics of groundwater flow system in the site are quantitatively described, i.e. distribution of hydraulic gradients, groundwater inflow rate into the storage caverns, and hydrogeologic influence area of the cavern. In this study, numerical models such as MODFLOW, FracMan/MAFIC and CONNECTFLOW are used for calculating the hydrogeological stability parameters. The design of a horizontal water curtain system requires considering the distance between water curtain and storage cavern, spacing of the water curtain boreholes, and injection pressure. From the numerical simulations at different scales, the optimum water curtain systems satisfying the containment criteria are obtained. The inflow rates into storage caverns estimated by a continuum model ranged from about 120 m$^3$/day during the operation stage to 130~140m$^3$/day during the construction stage, whereas the inflow rates by a fracture network model are 80~175m$^3$/day. The excavation works in the site will generate the excessive decline of groundwater level in a main fracture zone adjacent to the cavern. Therefore, the vertical water curtain system is necessary for sustaining the safe groundwater level in the fracture zone.

Evaluation of a Ground Heat Exchanger Appropriate for the Site of the Third Stage Construction of Incheon International Airport (인천국제공항 3단계 건설부지에 적합한 지중열교환기 시스템 평가 연구)

  • Cho, Nam-Hyun;Song, Jung-Tae;Yoon, Seok;Lee, Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.5
    • /
    • pp.23-33
    • /
    • 2015
  • In the present study, a ground heat exchanger was installed for each heat source in the system at the site to evaluate ground heat conductivity, constructability, and economic feasibility; the factors considered in the study included ground heat, groundwater, fillers (such as bentonite and pea pebbles) and the shape of the heat exchange pipe (e.g., U and D-U). The aim was to determine the ground heat exchanger appropriate for the geothermal system in the 3rd-phase construction of Incheon International Airport. A comparative cost analysis of the initial costs based on the above information showed that although the initial costs of the regular vertical closed loop-II and modified vertical closed loop were lower than those of the regular vertical closed loop-I, they could not be expected to deliver high economic efficiency from the viewpoint of constructability (filler injection, heat exchange pipe insertion). The initial costs proved to be higher in the case of Geohil.

Site Investigation for Pilot Scale $CO_2$ Sequestration by Magnetotelluric Surveys in Uiseong, Korea (이산화탄소 지중저장 Pilot 부지 선정을 위한 의성지역 MT 탐사)

  • Lee, Tae-Jong;Han, Nu-Ree;Ko, Kwang-Beom;Hwang, Se-Ho;Park, Kwon-Gyu;Kim, Hyung-Chan;Park, Yong-Chan
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.4
    • /
    • pp.299-308
    • /
    • 2009
  • A magentotelluric (MT) survey at the Uiseong area has been performed for the site investigation of pilot scale $CO_2$ sequestration. The purpose of the MT survey is to delineate deeply extended fracture systems that can act as a leakage path of injected $CO_2$ Plume. Since the target area is extremely noisy in electromagentic sense, low frequency data below 1 Hz cannot be used for inversion. Two- and three-dimensional interpretation of the MT data showed a very clear conductive anomaly, which has the direction of $N55\sim65^{\circ}W$ and is extended roughly down to 1.6 km. It have the same direction with the strike-slip faults, the Gaeum and Geumcheon Faults. On the contrary, the eastern part of the survey area shows relatively homogeneous to the depth of 2 km though some small fractures at shallow depths can be found. Test drilling and high-definition borehole surveys should be followed at the eastern part of the survey area and hydraulic fracturing is required for injection of $CO_2$, because mean porosity of the sedimetary rock in the area is only 1.47%.