• 제목/요약/키워드: Injection Molding Process

검색결과 906건 처리시간 0.028초

마이크로 분말사출성형에서 바인더 물성이 피드스탁 및 성형공정에 미치는 영향에 관한 연구 (A study on the effect of binder properties on feedstock and micro powder injection molding process)

  • 이원식;김용대
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.1-7
    • /
    • 2017
  • The fabrication process of micro pattern structure with high precision and high aspect ratio using powder injection molding (PIM) is developed. In the PIM process, the metal powder is mixed with the binder systems and the mixture is injected into the metal mold. The injection molded green parts are debinded and sintered to reach final shape and properties. In this method, the optimization of physical properties such as fluidity and strength of the binder system is essential for perfect filling the high aspect ratio micro-pattern. For this purpose, the correlation between the properties of the binder system and feedstock and ${\mu}-PIM$ process was investigated, and a binder system with low viscosity at low temperature(about $110^{\circ}C$) and high strength after cooling was investigated and applied. Employing this process, high precision parts with line type micro pattern structure which has pattern size $160{\mu}m$ and aspect ratio more than 2 can be manufactured.

사출압축성형에서 복굴절을 통한 성형조건에 따른 성형특성 고찰 (Investigation of Molding Characteristics in Injection Compression Molding According to Molding Conditions through Birefringence)

  • 이단비;남윤효;류민영
    • 폴리머
    • /
    • 제38권2호
    • /
    • pp.193-198
    • /
    • 2014
  • 렌즈 그리고 DVD 등과 같은 성형품들은 우수한 광학적 특성을 필요로 한다. 일반사출성형 공정은 캐비티 내에 압력이 높고 큰 온도변화를 포함하게 되어 성형품에 큰 잔류응력이 남아 광학적 품질이 저하된다. 따라서 이와 같은 제품들은 성형 시 잔류응력을 최소화하기 위해 캐비티 내의 압력을 낮게 그리고 균일하게 조절할 수 있는 사출압축성형 공정을 사용하는 경우가 많다. 본 연구에서는 실험을 통하여 사출압축 성형품에 영향을 주는 성형인자를 분석하였다. 다수 캐비티 금형을 이용하여 캐비티 간 품질편차도 고찰하였다. 실험에 사용한 재료는 투명수지인 PC와 PS이었다. 사출압축성형의 실험에서 공정변수로는 압축거리, 압축속도, 압축력 그리고 압축지연시간을 이용하였다. 실험결과, 사출압축성형 공정 변수 중 압축력과 압축지연시간 그리고 압축거리가 광학적 특성에 크게 영향을 미쳤으며 그 정도는 수지에 따라 다르게 나타났다. 이러한 현상은 사출압축성형 시 수지마다 유동성에 따라 최적의 성형조건이 있음을 의미하는 것이다.

Injection Molding of Vertebral Fixed Cage Implant

  • Yoo, Kyun Min;Lee, Seok Won;Youn, Jae Ryoun;Yoon, Do Heum;Cho, Yon Eun;Yu, Jae-Pil;Park, Hyung Sang
    • Fibers and Polymers
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2003
  • A vertebral cage is a hollow medical device which is used in spine forgery. By implanting the cage into the spine column, it is possible to restore disc and relieve pressure on the nerve roots. Most cages have been made of titanium alloys but they detract the biocompatibility. Currently PEEK (polyether ether ketone) if applied to various implants because it has good properties like heat resistance, chemical resistance, strength, and especially biocompatibility. A new shape of vertebral cage is designed and injection molding of PEEK is considered for production. Before injection molding of the cage, it is needed to evaluate process conditions and properties of the final product. Variables affecting the shrinkage of the cage are considered, e.g., injection time, packing pressure, mold temperature, and melt temperature. By using the numerical simula-tion program, MOLDFLOW, several cases are studied. Data files obtained by MOLDFLOW analysis are used for stress anal-ysis with ABAQUS, and shrinkage and residual stress fields are predicted. With these results, optimum process conditions are determined.

언더컷 처리장치 없는 사출성형을 위한 강제취출에 관한 연구 (A Study on the forced ejecting for injection molding without undercut processing unit)

  • 이희철;이희진;김경호;황재영;김영식;류호연
    • Design & Manufacturing
    • /
    • 제9권1호
    • /
    • pp.1-4
    • /
    • 2015
  • Recently, the mold industry has been developed to high-quality and high-productivity with various demands of the high-tech industry. Also, geometry parts of injection mold are complex and diverse optimum design through the injection molding analysis has become a matter of course. The mold industry is trying to revitalize the industry with demand technology development and manufacturing process improvement. However, products that have undercut is the need for a separate processing mechanism and structure of the mold is getting more complex, the cost is expensive. Therefore, improving the structure of the mold through a study on the forced ejecting for injection molding without undercut processing unit and to improve the productivity.

  • PDF

폴리카보네이트 사출성형에 따른 금형과 사출품에서 표면거칠기의 재현성 예측 (Reproducibility Prediction of Surface Roughness in Mold and Injected Parts through Polycarbonate Injection Molding)

  • 홍수룡;김승수;이상선;이지호;최원준;강명창
    • 한국기계가공학회지
    • /
    • 제16권3호
    • /
    • pp.131-137
    • /
    • 2017
  • In this study, we evaluated the surface roughness of mold and injected parts manufactured by polycarbonate (PC) injection molding. The mold surface was polished to produce six differentiated roughnesses with 12 areas using stones (#800, #1200), sandpapers (#800, #1200), and diamond compounds (#8000, #14000). Injected parts were created using 20mm/s injection speed, 80 bar holding pressure for 5 seconds, and $70^{\circ}C$ cooling water. Injected parts surface roughness (Sa) was measured randomly in 10 of 30 using an interferometer (NewView8000, zygo, USA). In the same way, mold surface was measured randomly 10 times on 12 polished areas. Surface roughness of molds and injected parts were compared, and a regression equation to predict mold surface roughness was proposed for specific injection molding parameters.

대면적 미세패턴 사출성형에서의 전사 특성 실험 (A study on the micro pattern replication properties of large area in injection molding)

  • 김태훈;유영은;제태진;김창완;박영우;최두선
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2007
  • We injection molded a thin plate with micro prism patterns on its surface and investigated the fidelity of replication of the micro pattern depending on the process parameter such as mold temperature, injection rate or packing pressure. The size of the $90^{\circ}$ prism pattern is $50{\mu}m$ and the size of the plate is $400mm{\times}400mm$. The thickness is 1mm. The fidelity of the replication turned out quite different according to the process parameters and location of the patterns of the plate. We measured the cavity pressure and temperature in real-time during the molding to analyze the effect of the local melt pressure and temperature on the micro pattern replication.

  • PDF

금속 인서트 사출 성형품의 수축 현상에 관한 연구 (A Study of Shrinkage Phenomena on Injection modeled Pa Metal Insert)

  • 김영수
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.112-118
    • /
    • 1999
  • Shrinkage behavior was investigated to obtain more accurate dimensions of injected molding parts for free and restricted shrinkage conditions. various parameters for metal inserted injection process, such as thickness of resin, holding pressure and time, mo이 temperature and restriction condition of mold, were considered for the analysis of shrinkage phenomena. For numerical analysis, MOLDFLOW software was used to find the deterministic parameters of filling time, temperature, pressure and holding time. Also , experimental shrinkage effects were measured through actual injection molding process and the resin thickness was under controlled as 3 mm , 5 mm, and 7mm for the shapes of plastic gear made of Polymide(PA) and Polyxymethlene(POM). The main parameters of these injection processes were found to be holding pressure, holding time and mold temperature in the case of metal inserted molding.

  • PDF

사출 도광판의 프리즘 패턴 전사성에 관한 실험적 연구 (A study on the prizm pattern replication in injection molding)

  • 김창완;유영은;김태훈;제태진;최두선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1537-1541
    • /
    • 2007
  • We injection molded a wedge type of plate with micro prizm patterns on its surface and investigated the fidelity of replication of the micro pattern depending on the process parameter such as mold temperature, melt temperature, injection rate or packing pressure. The size of the size of the $90^{\circ}$ prizm pattern is $50{\mu}m$ and the size of the plate is about 300㎜${\times}$200㎜. The thicknesses are 2.6㎜. and 0.7mm at each edge of the wedge type of plate. The fidelity of the replication turned out quite different according to the process parameters and location of the patterns on the plate. We measured the cavity pressure and temperature in real-time during the molding to analyze the effect of the local melt pressure and temperature on the micro pattern replication.

  • PDF

금속 염 첨가 방법을 이용하여 사출성형된 텅스텐 중합금의 소결거동 (Sintering Behavior of the Injection Molded W-Ni-Fe Heavy Alloy by Addition of Metallic Stat)

  • 김대건;류성수;김은표;이정근;김영도;문인형
    • 한국분말재료학회지
    • /
    • 제6권4호
    • /
    • pp.294-300
    • /
    • 1999
  • This study was carried out to investigate the possibility whether Metal Injection Molding (MIM) process could be applied to 95wt.%W-3.5wt.%Ni-1.5wt.%Fe heavy alloy in order to obtain an intricate shape. Methylcellulose was used in the injection molding for binder. $FeCl_2-4H_2O$ was added in solvent substituting Fe powder and $FeCl_2$ was doped on W-Ni premixed powder. When $FeCl_2-4H_2O$ was added in solvent, the binder separation occurred for injection molding so that the matrix content was changed. Such problem was solved when $FeCl_2$ was doped. In this study. the debinding process did not affect residual carbon content. The sintered microsouctures as addition methods of Fe element and the sintering temperature from $1420^{\circ}C$ to $1470^{\circ}C$, which are around the temperature of liquid phase formation, were observed.

  • PDF

100nm 급 Pattern 전사성 향상을 위한 나노 사출 성형 공정 최적화 연구 (Study on Optimization of Nano Injection Molding Process for Improving Transcription of 100nm-level Pattern)

  • 이재숙;이해곤;손성기;이종훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.81-85
    • /
    • 2006
  • In this study, we have been examined nano Injection Molding process which can improve transcription of 100nm-level pattern. We changed the various parameter (temperature of injection mold, clamp force, temperature of nozzle) which can be influence for improving transcription. And we measured and analyzed shapes of 100nm-level pattern by Automic Force Microscope for proving transcription. We made the Blu-ray Disc sample for proving transcription. And we measured HF-Signal and jitter. As a result, when the temperature of mold is more than $120^{\circ}C$ and the clamp force is more than 10 ton, We reached over 95 percent of transcription compared with stamper pattern. And we reached in-spec. value for HF-Signal and Jitter. Then we reached over 95 percent of transcription compared with stamper pattern.

  • PDF