• Title/Summary/Keyword: Injection Analysis

Search Result 3,044, Processing Time 0.031 seconds

Purification of Methioninase from Pseudomonas putida and Its Effect on the Uptake of ^11C-Methionine in Vivo. (Pseudomonas putida 유래 Methioninase의 정제 및 생체내 ^11C-Methionine 섭취에 미치는 영향)

  • 변상성;박귀근
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.4
    • /
    • pp.377-382
    • /
    • 2003
  • Purification of methioninase resulted in a yield of 69%, and SDS-PAGE analysis of the purified product revealed a single band of approximately 43 kDa in molecular weight. in vitro experiments with cancer cells incubated in methionine-free media demonstrated an increase in $^{11}$ C-methionine uptake to 25.8$\pm$1.1% at 6 hr, 31.8$\pm$0.8% at 24 hr, and 62.2$\pm$0.6% at 48hr, compared to controls. Treatment of the cancer cells with purified methioninase showed no decrease in survival after a 2 hr incubation with 0.01 U/ml, but survival of RR1022 cells decreased 30% after 24 to 48 hr incubation. SKOV-3 cells showed a 5% and 14% decrease in survival with 0.1 and 1 U/ml methioninase after 24 hr. After 48hr survival decreased 15% and 24% with 0.1 and 1 U/ml methioninase. Measurements of $^{11}$ C-methionine uptake in RR1022 cells demonstrated no change at 2 hr, but a 13.7$\pm$4.7% and 40.7$\pm$2.6% increase in uptake at 24 and 48 hr, respectively. SKOV-3 cells also showed no change at 2 hr, but had a 17.7$\pm$7.2% and 38.9$\pm$4.9% increase in $^{11}$ C-methionine uptake after 24 hr and 48 hr treatment with methioninase, respectively. $^{11}$ C-methionine PET imaging revealed clear visualization of both the tumors and contralateral infectious lesions. Administration of rMET appeared to result in a slight increase in tumor:nontumor contrast on $^{11}$ C-methionine PET images. Injection of purified methioninase also produced PET images where tumor uptake was higher than that of infectious lesions.

Disposal of CO in CO-Poisoning Dogs (일산화탄소중독견(一酸化炭素中毒犬) 체내(體內)에서의 일산화탄소처리능(一酸化炭素處理能)에 관(關)하여)

  • Ryo, Ung-Yun;Kang, Bann
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.93-99
    • /
    • 1968
  • The Present study attempted to analyze the fate of CO diffused into the circulating blood through the alveoli. Dogs were induced to CO poisoning by rebreathing CO gas mixture contained in Krog's spirometer, by closed circuit method, for 60 minutes. The spirometer was filled initially with 282 ml of CO and 20 liters of air and oxygen, so the composition of gases were arranged as 1.4% in CO and 50% in $O_2$ at the begining of the rebreathing. Oxygen was added corresponding to the utilization of $O_2$ by the animal in proceeding of the experiment. At 60th minutes of CO rebreathing, the concentration of CO in arterial blood and in mixed venous blood were analysed and compared with each other after the CO contents were corrected with the hematocrit measured in the arterial and mixed venous blood. The distribution of CO gas to other tissues was estimated by the analysis of CO diffused into the cystic bile and into the peritoneal gas pocket which was formed by injection of 300 ml air into the peritoneal cavity prior to the CO gas rebreathing. The blood volume was measured by dilution method using $^{51}Chromium$ tagged red cells. CO amount vanished in the animal body was calculated by subtraction of total CO content in blood stream and the CO remained in closed circuit breathing system from the CO amount given to the breathing system at the begining of the experiment. Results obtained are summarized as follows: 1. The content of CO corrected by the hematocrit value was slightly less in mixed venous blood than in arterial blood. The amount of CO diffused into the cystic bile and into the peritoneal cavity was averaged to 0.1% and 0.4% of the CO amount in 100 ml of blood, respectively. 2. For 60 minutes of CO rebreathing, CO-hemoglobin saturation reached about 77% at the 60th minutes, CO amount vanished in the experimental animal averaged 36.1 ml/dog/hr., or 21% of the total CO volume in the blood stream. The average vanishing rate of CO during 60 minutes of CO rebreathing per kg of body weight was 2.71 ml/hr. Production of CO measured in ten dogs under hypoxic condition averaged 0.023 ml/kg/hr. The major part of the CO vanished in the dogs seemed to be oxidized to $CO_2$ by various tissues of the animal. The conclusion might be delivered as such oxidation of CO to $CO_2$ by animal tissues can play a role in part of the process of recovery and protection of animal from CO-poisoning.

  • PDF

Amperometric Determination of Anthracycline Antibiotics with the Mercury Film Thin Layer Flow Cell (수은피막 박막흐름전지를 이용한 Anthracycline계 항생제의 전류법 정량)

  • Kim, Kyung Eun;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.470-475
    • /
    • 2004
  • The mercury film thin layer flow cell (MFTLFC) which yielded the highest sensitivity for the electrochemical reduction of doxorubicin was constructed by coating the glassy carbon working electrode (GCE; $A=0.208cm^2$) with $5{\mu}L$ of HgO coating solution (0.5% HgO + 0.25% polystyrene/cyclohexanone) and subsequently followed by applying a potential of -0.40 V for 300 sec in the flow stream of an acetate buffer of pH 4.5. The voltammogram of doxorubicin reached the diffusion current plateau at -0.53 V vs. a Ag/AgCl (3 M NaCl) in the MFTLFC. The diffusion current (Id) of doxorubicin at the MFTLFC was 1.7 times greater than the Id obtained at the TLFC employing a bare glassy carbon working electrode. When the peak areas (electric charge) were plotted vs. concentrations of standard anthracyclines, the calibration factors of doxorubicin and daunorubicin were $1.12{\times}10^8{\mu}C/M$ (coefficient of determination; $R^2$: 0.969) and $0.98{\times}10^8{\mu}C/M$> ($R^2$: 0.999), respectively in the concentration range between $1.0{\times}10^{-8}M$ and $1.0{\times}10^{-6}M$.

Characteristic Intracelluar Response to Lidocaine And MK-801 of Hippocampal Neurons: An In Vivo Intracellular Neuron Recording Study

  • Choi, Byung-Ju;Cho, Jin-Hwa
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.3
    • /
    • pp.297-305
    • /
    • 1998
  • This study used in vivo intracellular recording in rat hippocampus to evaluate the effect of lidocaine and MK-801 on the membrane properties and the synaptic responses of individual neurons to electrical stimulation of the commissural pathway. Cells in control group typically fired in a tonic discharge mode with an average firing frequency of $2.4{\pm}0.9$ Hz. Neuron in MK-801 treated group (0.2 mg/kg, i.p.) had an average input resistance of $3.28{\pm}5.7\;M{\Omega}$ and a membrane time constant of $7.4{\pm}1.8$ ms. These neurons exhibited $2.4{\pm}0.2$ ms spike durations, which were similar to the average spike duration recorded in the neurons of the control group. Slightly less than half of these neurons were firing spontaneously with an average discharge rate of $2.4{\pm}1.1$ Hz. The average peak amplitude of the AHP following the spikes in these groups was $7.4{\pm}0.6$ mV with respect to the resting membrane potential. Cells in MK-801 and lidocaine treated group (5 mg/kg, i.c.v.) had an average input resistance of $3.45{\pm}6.0\;M{\Omega}$ and an average time constant of $8.0{\pm}1.4$ ms. The cells were firing spontaneously at an average discharge rate of $0.6{\pm}0.4$ Hz. Upon depolarization of the membrane by 0.8 nA for 400 ms, all of the tested cells exhibited accommodation of spike discharge. The most common synaptic response contained an EPSP followed by early-IPSP and late-IPSP. Analysis of the voltage dependence revealed that the early-IPSP and late-IPSP were putative $Cl^--and\;K^+-dependent$, respectively. Systemic injection of the NMDA receptor blocker, MK-801, did not block synaptic responses to the stimulation of the commissural pathway. No significant modifications of EPSP, early-IPSP, or late-IPSP components were detected in the MK-801 and/or lidocaine treated group. These results suggest that MK-801 and lidocaine manifest their CNS effects through firing pattern of hippocampal pyramidal cells and neural network pattern by changing the synaptic efficacy and cellular membrane properties.

  • PDF

Pharmacokinetic/Pharmacodynamic Analysis of Metoprolol in Dogs (실험견에서 Metoprolol 약리효과의 약동/력학적 검토)

  • Oh, Dong-Jin;Jang, In-Jin;Lee, Kyung-Hun;Yim, Dong-Seok;Kim, Hyung-Kee;Shin, Sang-Goo;Park, Chan-Woong;Shin, Jae-Gook
    • The Korean Journal of Pharmacology
    • /
    • v.31 no.2
    • /
    • pp.251-259
    • /
    • 1995
  • Pharmacokinetics and pharmacodynamics of metoprolol, a selective beta-l blocker, were examined for 360 minutes after intravenous bolus administration of metoprolol to 6 dogs. Plasma concentration and excreted amount in the urine metoprolol were measured by liquid chromatography with fluorescence detection. PR interval and heart rate were measured by ECG monitoring. Blood pressure was monitored through intraarterial catheter in femoral artery and cardiac output by thermodilution method using Swan-Ganz catheter. To analyze the effect site concentration-response relationship, plasma concentration and pharmacological effects were simultaneously fitted to a two pharmacokinetic compartment linked to pharmacodynamic model with NONLIN program. Results are as follows. 1) The plasma concentration of metoprolol after intrvenous injection decreased biexponentially. The terminal half-life estimated was $1.33{\pm}0.40$ hours and the volume of distribution at steady state (Vdss) and the total body clearance were $1.04{\pm}0.4\;L/kg,\;6.55{\pm}2.21\;L/hr$, respectively. The central compartment volume of distribution and peripheral compartment volume of distribution were $0.35{\pm}0.14L/kg\;and\;0.69{\pm}0.34L/kg$. The renal clearance and intercompartment clearance were $0.53{\pm}0.25\;L/min\;and\;0.35{\pm}0.19\;L/min$. 2) Simulated biophase concentration-response curve shows hyperbolic relationship and the estimated concentration-effect relationship was best explained by Emax model when the prolongation of PR interval and the reduction of the heart rate were used as pharmacodynamic parameters. Emax and EC50 were estimated to be $26.3{\pm}4.7\;msec\;and\;88.8{\pm}82.3\;g/ml$ for PR interval, and $48.7{\pm}18.8\;beats/min\;and\;113.5{\pm}78.7\;ng/ml$ for heart rate, respectively. 3) The changes of cardiac output-effect site concentration relationship was best fitted by a linear model and the slope of the relationship was $0.005{\pm}0.003$. Diastolic blood pressure-effect site concentration relationship was also explained by the linear model and the slope of the relationship was $0.038{\pm}0.034$.

  • PDF

Nursing Students' Safety-Climate, Perception and Performance of Standard Precautions for Healthcare-associated Infection Control (간호대학생의 의료관련 감염관리를 위한 표준주의 안전환경과 인지도, 수행도)

  • Cha, Ji-eun;Cho, Ji-Young;Kim, Yu-Gyeong;Nam, Guk-Hee;Lee, Seo-Young;Lee, Sun-Young;Lee, A-Rim;Lee, Ji-Yae;Chae, Su-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.72-83
    • /
    • 2017
  • This study was conducted to investigate nursing students' safety-climate: perception and performance of standard precautions for healthcare-associated infection control. We also identified actors influencing performance of standard precautions. Data were collected from 246 junior and senior nursing students at nine colleges in D city from July to September, 2016. The mean score of performance was significantly lower than that of perception in all areas of standard precautions. The biggest difference between perception and performance was in the usage of personal protective equipment and safe injection practices. We also detected significant positive correlations among safety-climate, perception, and performance of standard precautions. In the regression analysis, performance of standard precautions was influenced by safety-climate and grade accounting for 10.7% of variance. To improve healthcare-associated infection control among nursing students, safer and more supportive practical environments need to be provided, and new training strategies such as simulation education need to be expanded.

Preventive effect of fermented red ginseng on cisplatin-induced nephrotoxicity mouse (Cisplatin으로 유도된 신손상 마우스 모델에 대한 발효홍삼의 예방효능)

  • Hyun, Ja-Kyoung;Kwon, O Jun;Lee, Joo Young;Roh, Seong-Soo;Seo, Young-Bae
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.2
    • /
    • pp.113-124
    • /
    • 2016
  • Red ginseng is known to have many beneficial effects. Cisplatin, an effective antineoplastic drug, can cause many side effects like irreversible sensorineural hearing loss and serious tinnitus in humans. This study is aimed to reduce a cisplatin's side effect, nephrotoxicity by fermentated korean red ginseng. Korea ginseng was produced by steaming and dring and fermentation. And mice were divided into 4 groups- (A) normal mice, (B) Vehicle treated cisplatin mice, (C) RG0F0-treated cisplatin mice, (D) RG8F3-treated cisplatin mice. C and D groups were feed each material 200 mg/kg/day during 4 days. And cisplatin 20 mg/kg injected to B, C, and D groups as abdominal injection. After 24 h, blood sample was collected. The kidneys were harvested for histological, immuno histochemical and western blot analysis. 1,1-diphenyl-2-picrylhydrazyl (DPPH) and 2,2'-azinobis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) radical scavenging activity was depended on steaming hours. RG0F0 and RG8F3 (ginseng-8 h steamed and fermented by Saccharomyces cerevisiae) were showed antioxidants effect in DPPH and ABTS radical scavenging activity. Component amounts according to steaming hours. 8 h steamed red ginseng had the most ingredients of ginsenoside. Treatments with RG8F3 reduced cisplatin-induced nephrotoxicity in the mice resulting in increase of GSH and decrease of ROS, BUN, creatinine, and inflammatory mediators. This result seems to be involved with the restriction of the inflammation in the kidney. Therefore, fermented red ginseng might have therapeutic efficacy in reduce kidney injury induced by cisplatin treatment.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

Characteristic of $^{18}F$-FDG Excretion According to Use Diuretics in $^{18}F$-FDG of PET/CT ($^{18}F$-FDG PET/CT 검사에서 이뇨제 사용여부에 따른 $^{18}F$-FDG 배설 특성)

  • Jang, Dong-Gun;Yang, Seoung-Oh;Lee, Sang-Ho;Bae, Jong-Lim;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.151-156
    • /
    • 2012
  • $^{18}F$-fluorodeoxyglucose ($^{18}F$-FDG) causes a significant amount of radioactivity retention in kidneys and urinary tract and degrades image quality and diagnostic performance. Diuretics are used to perform tests and prevent the urinary tract retention of $^{18}F$-FDG. The purpose of the study is to investigate how the diuretics affect images and excretion rates of $^{18}F$-FDG. The study consists of a group using diuretics for patients with no primary tumors or transfer lesions in kidneys according to PET/CT images, a group using physiological saline and the control group injecting only $^{18}F$-FDG and SUVs are measured by configuring interested areas for each group. Also, SUVs are compared and evaluated depending on the lasix injection after basic inspection and injecting $^{18}F$-FDG for quantitative analysis. The study shows that images with decreased background radioactivity and increased urine excretion due to using diuretics. However, an opposite result that there is no change in the amount of radioactivity in urine appears. The study concludes that the diuretics may decrease background radioactivity in the images but may not affect the $^{18}F$-FDG excretion.

Treatment of Phalangeal Bone Defect Using Autologous Stromal Vascular Fraction from Lipoaspirated Tissue (자가기질혈관분획을 이용한 수지골 결손 환자의 치료)

  • Jeong, Tae-Won;Ji, Yi-Hwa;Kim, Deok-Woo;Dhong, Eun-Sang;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.438-444
    • /
    • 2011
  • Purpose: Adipose-derived stromal cells (ASCs) are readily harvested from lipoaspirated tissue or subcutaneous adipose tissue fragments. The stromal vascular fraction (SVF) is a heterogeneous set of cell populations that surround and support adipose tissue, which includes the stromal cells, ASCs, that have the ability to differentiate into cells of several lineages and contains cells from the microvasculature. The mechanisms that drive the ASCs into the osteoblast lineage are still not clear, but the process has been more extensively studied in bone marrow stromal cells. The purpose of this study was to investigate the osteogenic capacity of adipose derived SVF cells and evaluate bone formation following implantation of SVF cells into the bone defect of human phalanx. Methods: Case 1 a 43-year-old male was wounded while using a press machine. After first operation, segmental bone defects of the left 3rd and 4th middle phalanx occurred. At first we injected the SVF cells combined with demineralized bone matrix (DBM) to defected 4th middle phalangeal bone lesion. We used P (L/DL)LA [Poly (70L-lactide-co-30DL-lactide) Co Polymer P (L/DL)LA] as a scaffold. Next, we implanted the SVF cells combined with DBM to repair left 3rd middle phalangeal bone defect in sequence. Case 2 was a 25-year-old man with crushing hand injury. Three months after the previous surgery, we implanted the SVF cells combined with DBM to restore right 3rd middle phalangeal bone defect by syringe injection. Radiographic images were taken at follow-up hospital visits and evaluated radiographically by means of computerized analysis of digital images. Results: The phalangeal bone defect was treated with autologous SVF cells isolated and applied in a single operative procedure in combination with DBM. The SVF cells were supported in place with mechanical fixation with a resorbable macroporous sheets acting as a soft tissue barrier. The radiographic appearance of the defect revealed a restoration to average bone density and stable position of pharyngeal bone. Densitometric evaluations for digital X-ray revealed improved bone densities in two cases with pharyngeal bone defects, that is, 65.2% for 4th finger of the case 1, 60.5% for 3rd finger of the case 1 and 60.1% for the case 2. Conclusion: This study demonstrated that adipose derived stromal vascular fraction cells have osteogenic potential in two clinical case studies. Thus, these reports show that cells from the SVF cells have potential in many areas of clinical cell therapy and regenerative medicine, albeit a lot of work is yet to be done.