• Title/Summary/Keyword: Injecting pressure

Search Result 116, Processing Time 0.026 seconds

Development of Osmotic Infusion Pump (삼투압 약물주입 펌프의 개발)

  • Kim, Dong Sun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.471-475
    • /
    • 2015
  • Because of increasing demand, a small portable drug injector that uses osmotic pressure for its operation force is developed, and its performance is evaluated. The osmotic drug injector can be small and lightweight because it does not require heavy batteries and an actuator, unlike previous electromechanical drug injectors. Moreover, its injection pressure can be sustained longer than that of previous elastic drug injectors. The new device is composed of a drug sac, osmotic pressure chamber, semipermeable membrane, and solvent chamber. To evaluate its performance, an in-vitro experiment was designed to measure the outflow and the injection pressure with respect to time. The experimental results show that the new drug infuser can continuously deliver 20 ml drug over a period of 20 h. The maximum injecting pressure was over 400 mmHg. Which prevents backflow caused by changes in the outlet pressure resulting from changes to the position of the device and the patient's posture.

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

Effect of injection pressure on the atomization characteristics of a liquid sheet-type swirl injector for Urea-SCR system (Urea-SCR시스템 액막형 선회분사기의 분사압력변화에 따른 무특성에 관한 연구)

  • Kim, Duckjin;Yang, Donguk;Lee, Jeekeun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.510-519
    • /
    • 2013
  • In this study, the spray characteristics of a pressure swirl atomizer classified into a liquid sheet-type swirl nozzle for Urea-SCR system were investigated experimentally with the variation of injection pressure. The length to diameter ratio ($l_o/d$) of the nozzle was 3.1, and the swirler was set inside the nozzle tip to give injecting fluid angular momentum. The injection duration of the nozzle was controlled by PWM (pulse width modulation) modes. The development processes of the spray were imaged by a 2-D PIV system, and the change of spray angle was measured. The atomization characteristics, including axial velocity and SMD, were measured using a 2-D PDA system with the injection pressures at room temperature and ambient pressure conditions. As the experimental results, the injection pressure had a significant impact on the spray structure showing a different shape around the spray leading edge, and the smaller SMD was observed with increasing injection pressures, which was similar to that of the previous work.

Effect of process pressure and nitrogen addition ratio on the uniformity of hardening depth and surface properties of Cr-Mo low alloy steel in vacuum carburizing (Cr-Mo 저합금강의 진공침탄 공정 압력 및 질소 첨가 비율에 따른 경화깊이 균일도 및 표면 특성 효과)

  • Gi-hoon Kwon;Hyunjun Park;;Young-Kook Lee;Kyoungil Moon
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.1
    • /
    • pp.94-103
    • /
    • 2023
  • The effects of carburizing pressure and gas ratio on vacuum carburizing properties (uniformity and surface characteristics) have been studied through the analyses of carbon concentration, hardness, surface color, surface roughness and type of carbon bonding. AISI 4115 steel specimens were carburized with various pressures (1, 5, and 10 Torr) at different locations (P1, P2, P3, P4, P5, and P6) inside a furnace held at 950 ℃. Since the carburizing pressure represents the density of the carburizing gas, it plays an important role in improving the carburizing uniformity according to locations in the furnace. As the carburizing pressure increased, the carburizing uniformity according to the sample location was improved, but the surface of the carburized specimen was discolored due to the residual acetylene gas, which does not contribute to the carburizing reaction. Therefore, the carburizing uniformity and surface discoloration have been improved by injecting acetylene gas (carburizing gas) and nitrogen gas (non-reactive gas) in a specific ratio.

Effects of vasopressin administration in the oral cavity on cardiac function and hemodynamics in rats

  • Fukami, Hayato;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • Background: The vasoconstrictive effect of epinephrine in local anesthetics affects the heart, which leads to hesitation among dentists in injecting local anesthetics into patients with cardiovascular disease. Due to its vasoconstrictive effects, the present study investigated the effects of vasopressin administration on cardiac function in rats. Methods: Experiment 1 aimed to determine the vasopressin concentration that could affect cardiac function. An arterial catheter was inserted into the male Wistar rats. Next, 0.03, 0.3, and 3.0 U/mL arginine vasopressin (AVP) (0.03V, 0.3V, and 3.0V) was injected into the tongue, and the blood pressure was measured. The control group received normal saline only. In Experiment 2, following anesthesia infiltration, a pressure-volume catheter was placed in the left ventricle. Baseline values of end-systolic elastance, end-diastolic volume, end-systolic pressure, stroke work, stroke volume, and end-systolic elastance were recorded. Next, normal saline and 3.0V AVP were injected into the tongue to measure their effect on hemodynamic and cardiac function. Results: After 3.0V administration, systolic blood pressures at 10 and 15 min were higher than those of the control group; they increased at 10 min compared with those at baseline. The diastolic blood pressures at 5-15 min were higher than those of the control group; they increased at 5 and 10 min compared with those at baseline. The preload decreased at 5 and 10 min compared to that at baseline. However, the afterload increased from 5 to 15 min compared with that of the control group; it increased at 10 min compared with that at baseline. Stroke volume decreased at 10 and 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Stroke work decreased from 5 to 15 min compared with that of the control group; it decreased from 5 to 15 min compared with that at baseline. Conclusion: Our results showed that 3.0 U/mL concentration of vasopressin resulted in increased blood pressure, decreased stroke volume and stoke work, decreased preload and increased afterload, without any effect on myocardial contractility.

A Study on the Heating of Lipiodol during Lymphangiography (림프관 조영술 시 리피오돌의 가온에 관한 고찰)

  • Kang, Rae-Wook;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.597-602
    • /
    • 2020
  • The study was conducted to improve the efficiency of the test and to reduce the exposure dose of patients and operators by analyzing the difference in the moving speed of Lipiodol according to the temperature during lymphography. The device for injecting Lipiodol at a constant pressure was self-made, and after inserting Lipiodol into the Connecting Tube, the moving speed of the contrast agent was photographed at temperatures of 26℃, 36℃, and 46℃ using a heat transfer device. Lipiodol movement time from the Support Catheter to 20cm was measured and analyzed, and statistical significance was confirmed. In the 46℃ environment, the average moving time was 11 seconds, at 36℃ the average was 13 seconds, and at 26℃ the average was 17 seconds. Lipiodol showed a significant difference in moving time with increasing temperature (p<.001), and it was confirmed that the higher the temperature, the faster the moving speed. In the case of lymphangiography, when heated to a certain temperature (46 degrees) rather than injecting Lipiodol at room temperature, the injection speed can be increased and the speed of movement in the lymphatic vessel can be improved.

Electrodelss Plasma Torch Powered by Microwave and Its Applications (무전극 마이크로웨이브 플라즈마 토치와 응용)

  • Hong, Yong-Cheol;Jun, Hyung-Won;Lho, Tai-Hyeop;Lee, Bong-Ju;Uhm, Han-Sup
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.889-892
    • /
    • 2009
  • A microwave plasma torch at the atmospheric pressure by making use of magnetrons operated at the 2.45 GHz and used in a home microwave oven has been developed. This electrodeless torch can be used to various areas, including industrial, environmental and military applications. Although the microwave plasma torch has many applications, we in the present work focused on the microwave plasma torch operated in pure steam and several applications, which may be used in future and right now. For example, a high-temperature steam microwave plasma torch may have a potential application of the hydrocarbon fuel reforming at one atmospheric pressure. Moreover, the radicals including hydrogen, oxygen and hydroxide molecules are abundantly available in the steam torch, dramatically enhancing the reaction speed. Also, the microwave plasma torch can be used as a high-temperature, large-volume plasma burner by injecting hydrocarbon fuels in gas, liquid, and solid into the plasma flame. Lastly, we briefly report an underway research, which is remediation of soils contaminated with oils, volatile organic compounds, heavy metals, etc.

  • PDF

Characteristics of the Sealing Pressure of a Magnetic Fluid Shaft Seal for Intra-Cardiac Axial Flow Blood Pumps (심장 내 이식형 축류 혈액 펌프용 자성 유체 축봉의 내압 특성)

  • KIM, Dong-Wook;Mitamura , Yoshinori
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.10
    • /
    • pp.477-482
    • /
    • 2002
  • One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments confirmed these advantages. The seal body was composed of a Nd-Fe-B magnet and two pole pieces; the seal was formed by injecting magnetic fluid into the gap (50${\mu}m$) between the pole pieces and the motor shaft. To contain the ferro-fluid in the seal and to minimize the possibility of magnetic fluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 31kPa with magnetic fluid LS-40 (saturated magnetization, 24.3 KA/m) at a motor speed of 10,000 rpm and 53kPa under static conditions(0mmHg). The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intra-cardiac axial flow blood pump.

Development of Steam Plasma-Enhanced Coal Gasifier and Future Plan for Poly-Generation

  • Hong, Yong-Cheol;Lho, Taihyeop;Lee, Bong-Ju;Uhm, Han-Sup
    • Journal of the Korean institute of surface engineering
    • /
    • v.42 no.3
    • /
    • pp.139-144
    • /
    • 2009
  • A microwave plasma torch at the atmospheric pressure by making use of magnetrons operated at the 2.45 GHz and used in a home microwave oven has been developed. This electrodeless torch can be used to various areas, including industrial, environmental and military applications. Although the microwave plasma torch has many applications, we in the present work focused on the microwave plasma torch operated in pure steam and several applications, which may be used in future and right now. For example, a high-temperature steam microwave plasma torch may have a potential application of the hydrocarbon fuel reforming at one atmospheric pressure. Moreover, the radicals including hydrogen, oxygen and hydroxide molecules are abundantly available in the steam torch, dramatically enhancing the reaction speed. Also, the microwave plasma torch can be used as a high-temperature, large-volume plasma burner by injecting hydrocarbon fuels in gas, liquid, and solid into the plasma flame. Finally, we briefly report treatment of soils contaminated with oils, volatile organic compounds, heavy metals, etc., which is an underway research in our group.

Silicon Etching Process of NF3 Plasma with Residual Gas Analyzer and Optical Emission Spectroscopy in Intermediate Pressure (잔류가스분석기 및 발광 분광 분석법을 통한 중간압력의 NF3 플라즈마 실리콘 식각 공정)

  • Kwon, Hee Tae;Kim, Woo Jae;Shin, Gi Won;Lee, Hwan Hee;Lee, Tae Hyun;Kwon, Gi-Chung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.97-100
    • /
    • 2018
  • $NF_3$ Plasma etching of silicon was conducted by injecting only $NF_3$ gas into reactive ion etching. $NF_3$ Plasma etching was done in intermediate pressure. Silicon etching by $NF_3$ plasma in reactive ion etching was diagnosed through residual gas analyzer and optical emission spectroscopy. In plasma etching, optical emission spectroscopy is generally used to know what kinds of species in plasma. Also, residual gas analyzer is mainly to know the byproducts of etching process. Through experiments, the results of optical emission spectroscopy during silicon etching by $NF_3$ plasma was analyzed with connecting the results of etch rate of silicon and residual gas analyzer. It was confirmed that $NF_3$ plasma etching of silicon in reactive ion etching accords with the characteristic of reactive ion etching.